• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Mars Express >> ASPERA-3
VOLUME 2: MARS EXPRESS ASPERA3 RDR ELS DATA View Errata Order Volume Toggle viewing into expanded mode
MEX-M-ASPERA3-3-RDR-ELS-EXT2-V1.0 PDS 3      CERTIFIED
Start Time: 2007-10-01 21:23:50
VOLUME 2: MARS EXPRESS ASPERA3 RDR ELS DATA
VOLUME 2: MARS EXPRESS ASPERA3 RDR ELS DATA
Citiation Information
Lundin, R., S. Barabash, D. Winningham, R. Frahm, MARS EXPRESS ASPERA-3 CAL RDR ELECTRON SPECTROMTR EXT2 V1.0, MEX-M-ASPERA3-3-RDR-ELS-EXT2-V1.0, ESA Planetary Science Archive (PSA), NASA Planetary Data System (PDS), 2005
Top/ DATA/ 2007/ 335_365DEC / click here to download folders and files
ELSSCIH20073350014DNFS01
Start Time: 2007-335T00:14:59.179 Stop Time: 2007-335T02:47:03.660
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073350615DNFS01
Start Time: 2007-335T06:15:34.471 Stop Time: 2007-335T09:32:08.530
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073351300DNFS01
Start Time: 2007-335T13:00:39.311 Stop Time: 2007-335T15:17:23.917
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073352034DNFS01
Start Time: 2007-335T20:34:33.733 Stop Time: 2007-335T23:03:25.528
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073360230DNFS01
Start Time: 2007-336T02:30:52.154 Stop Time: 2007-336T05:49:01.997
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073360915DNFS01
Start Time: 2007-336T09:15:56.525 Stop Time: 2007-336T12:30:33.829
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073361705DNFS01
Start Time: 2007-336T17:05:51.754 Stop Time: 2007-336T19:19:43.697
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073370532DNFS01
Start Time: 2007-337T05:32:58.388 Stop Time: 2007-337T08:52:44.761
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073371219DNFS01
Start Time: 2007-337T12:19:39.322 Stop Time: 2007-337T13:00:22.648
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073371304DNFS01
Start Time: 2007-337T13:04:34.774 Stop Time: 2007-337T15:39:52.601
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073371906DNFS01
Start Time: 2007-337T19:06:47.161 Stop Time: 2007-337T22:26:01.935
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073380933DNFS01
Start Time: 2007-338T09:33:25.090 Stop Time: 2007-338T12:01:45.542
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073381527DNFS01
Start Time: 2007-338T15:27:35.978 Stop Time: 2007-338T16:08:02.770
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073381612DNFS01
Start Time: 2007-338T16:12:14.864 Stop Time: 2007-338T18:49:08.600
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073382214DNFS01
Start Time: 2007-338T22:14:26.941 Stop Time: 2007-339T01:37:09.002
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073390141DNFS01
Start Time: 2007-339T01:41:21.222 Stop Time: 2007-339T01:51:25.819
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073390523DNFS01
Start Time: 2007-339T05:23:05.374 Stop Time: 2007-339T08:24:05.802
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073391148DNFS01
Start Time: 2007-339T11:48:20.049 Stop Time: 2007-339T12:28:47.279
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073391232DNFS01
Start Time: 2007-339T12:32:58.999 Stop Time: 2007-339T15:11:29.484
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073391835DNFS01
Start Time: 2007-339T18:35:11.730 Stop Time: 2007-339T19:15:41.241
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073391919DNFS01
Start Time: 2007-339T19:19:52.993 Stop Time: 2007-339T21:58:23.761
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073400122DNFS01
Start Time: 2007-340T01:22:05.913 Stop Time: 2007-340T04:45:36.973
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073400832DNFS01
Start Time: 2007-340T08:32:16.406 Stop Time: 2007-340T11:33:17.518
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073401455DNFS01
Start Time: 2007-340T14:55:55.516 Stop Time: 2007-340T15:36:27.060
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073401540DNFS01
Start Time: 2007-340T15:40:39.031 Stop Time: 2007-340T18:20:45.892
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073402142DNFS01
Start Time: 2007-340T21:42:51.910 Stop Time: 2007-340T22:23:17.702
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073402227DNFS01
Start Time: 2007-340T22:27:29.985 Stop Time: 2007-341T01:07:37.595
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073410429DNFS01
Start Time: 2007-341T04:29:43.529 Stop Time: 2007-341T07:55:23.398
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073411141DNFS01
Start Time: 2007-341T11:41:24.387 Stop Time: 2007-341T14:42:25.314
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073411803DNFS01
Start Time: 2007-341T18:03:27.186 Stop Time: 2007-341T18:43:59.291
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073411848DNFS01
Start Time: 2007-341T18:48:11.011 Stop Time: 2007-341T21:29:54.305
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073420050DNFS01
Start Time: 2007-342T00:50:24.116 Stop Time: 2007-342T01:29:33.281
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073420415DNFS01
Start Time: 2007-342T04:15:03.207 Stop Time: 2007-342T04:16:49.583
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073420737DNFS01
Start Time: 2007-342T07:37:19.390 Stop Time: 2007-342T11:04:55.761
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073421109DNFS01
Start Time: 2007-342T11:09:07.887 Stop Time: 2007-342T11:19:12.390
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073421450DNFS01
Start Time: 2007-342T14:50:46.508 Stop Time: 2007-342T17:51:47.873
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073422111DNFS01
Start Time: 2007-342T21:11:13.558 Stop Time: 2007-342T21:51:36.821
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073422155DNFS01
Start Time: 2007-342T21:55:50.072 Stop Time: 2007-343T00:39:10.211
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073430640DNFS01
Start Time: 2007-343T06:40:13.536 Stop Time: 2007-343T07:26:24.642
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073431044DNFS01
Start Time: 2007-343T10:44:46.109 Stop Time: 2007-343T14:13:39.205
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073431800DNFS01
Start Time: 2007-343T18:00:00.371 Stop Time: 2007-343T19:56:42.814
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073440714DNFS01
Start Time: 2007-344T07:14:49.510 Stop Time: 2007-344T10:37:16.912
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073441356DNFS01
Start Time: 2007-344T13:56:10.534 Stop Time: 2007-344T16:33:32.330
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073442258DNFS01
Start Time: 2007-344T22:58:13.535 Stop Time: 2007-345T00:15:49.778
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073450333DNFS01
Start Time: 2007-345T03:33:39.212 Stop Time: 2007-345T07:04:41.271
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073451022DNFS01
Start Time: 2007-345T10:22:30.739 Stop Time: 2007-345T10:39:01.087
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073451226DNFS01
Start Time: 2007-345T12:26:05.117 Stop Time: 2007-345T13:53:52.278
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073451711DNFS01
Start Time: 2007-345T17:11:09.708 Stop Time: 2007-345T20:43:44.179
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073452047DNFS01
Start Time: 2007-345T20:47:55.899 Stop Time: 2007-345T20:58:00.464
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073460031DNFS01
Start Time: 2007-346T00:31:22.496 Stop Time: 2007-346T03:32:23.891
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073460648DNFS01
Start Time: 2007-346T06:48:37.197 Stop Time: 2007-346T07:29:13.991
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073460733DNFS01
Start Time: 2007-346T07:33:26.054 Stop Time: 2007-346T07:38:01.149
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073462137DNFS01
Start Time: 2007-346T21:37:56.467 Stop Time: 2007-346T23:59:37.571
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073470347DNFS01
Start Time: 2007-347T03:47:55.375 Stop Time: 2007-347T06:48:56.927
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073471004DNFS01
Start Time: 2007-347T10:04:06.111 Stop Time: 2007-347T13:38:21.432
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073471652DNFS01
Start Time: 2007-347T16:52:26.418 Stop Time: 2007-347T17:32:57.929
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073471737DNFS01
Start Time: 2007-347T17:37:09.899 Stop Time: 2007-347T20:27:28.009
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073472341DNFS01
Start Time: 2007-347T23:41:00.938 Stop Time: 2007-348T03:16:20.123
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073480910DNFS01
Start Time: 2007-348T09:10:25.074 Stop Time: 2007-348T10:05:29.871
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073481318DNFS01
Start Time: 2007-348T13:18:30.744 Stop Time: 2007-348T13:59:09.132
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073481403DNFS01
Start Time: 2007-348T14:03:21.383 Stop Time: 2007-348T15:09:26.217
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073482308DNFS01
Start Time: 2007-348T23:08:13.800 Stop Time: 2007-348T23:44:01.874
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073490255DNFS01
Start Time: 2007-349T02:55:58.649 Stop Time: 2007-349T06:33:22.865
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073490637DNFS01
Start Time: 2007-349T06:37:34.888 Stop Time: 2007-349T06:47:39.485
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073491021DNFS01
Start Time: 2007-349T10:21:07.366 Stop Time: 2007-349T13:22:08.889
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073491633DNFS01
Start Time: 2007-349T16:33:33.632 Stop Time: 2007-349T17:14:05.113
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073491718DNFS01
Start Time: 2007-349T17:18:17.677 Stop Time: 2007-349T20:11:16.227
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073492322DNFS01
Start Time: 2007-349T23:22:08.876 Stop Time: 2007-350T03:00:08.593
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073500611DNFS01
Start Time: 2007-350T06:11:01.247 Stop Time: 2007-350T09:49:33.305
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073501337DNFS01
Start Time: 2007-350T13:37:43.497 Stop Time: 2007-350T16:38:45.772
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073501948DNFS01
Start Time: 2007-350T19:48:34.298 Stop Time: 2007-350T21:04:01.696
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073510238DNFS01
Start Time: 2007-351T02:38:29.899 Stop Time: 2007-351T06:18:06.619
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073510928DNFS01
Start Time: 2007-351T09:28:59.364 Stop Time: 2007-351T13:08:35.418
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073511654DNFS01
Start Time: 2007-351T16:54:11.490 Stop Time: 2007-351T20:39:09.649
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073512339DNFS01
Start Time: 2007-351T23:39:21.080 Stop Time: 2007-352T03:30:44.489
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073520628DNFS01
Start Time: 2007-352T06:28:47.691 Stop Time: 2007-352T07:08:00.421
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073520717DNFS01
Start Time: 2007-352T07:17:33.579 Stop Time: 2007-352T10:22:52.289
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073521318DNFS01
Start Time: 2007-352T13:18:47.184 Stop Time: 2007-352T17:23:02.533
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073522016DNFS01
Start Time: 2007-352T20:16:17.366 Stop Time: 2007-352T20:39:13.498
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073522059DNFS01
Start Time: 2007-352T20:59:17.348 Stop Time: 2007-353T00:06:35.966
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073530258DNFS01
Start Time: 2007-353T02:58:46.427 Stop Time: 2007-353T05:52:14.792
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073530556DNFS01
Start Time: 2007-353T05:56:26.793 Stop Time: 2007-353T06:57:57.998
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073530948DNFS01
Start Time: 2007-353T09:48:32.264 Stop Time: 2007-353T09:52:43.171
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073531157DNFS01
Start Time: 2007-353T11:57:08.550 Stop Time: 2007-353T13:49:33.958
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073531623DNFS01
Start Time: 2007-353T16:23:34.282 Stop Time: 2007-353T16:38:46.442
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073531642DNFS01
Start Time: 2007-353T16:42:58.318 Stop Time: 2007-353T17:49:18.524
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073531753DNFS01
Start Time: 2007-353T17:53:42.026 Stop Time: 2007-353T20:45:04.638
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073532338DNFS01
Start Time: 2007-353T23:38:18.488 Stop Time: 2007-354T03:33:27.182
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073540618DNFS01
Start Time: 2007-354T06:18:08.761 Stop Time: 2007-354T09:21:18.251
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073542114DNFS01
Start Time: 2007-354T21:14:16.987 Stop Time: 2007-355T00:06:43.944
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073550300DNFS01
Start Time: 2007-355T03:00:15.368 Stop Time: 2007-355T07:00:13.532
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073550937DNFS01
Start Time: 2007-355T09:37:26.237 Stop Time: 2007-355T13:52:24.029
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073551627DNFS01
Start Time: 2007-355T16:27:28.478 Stop Time: 2007-355T19:26:45.376
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073551930DNFS01
Start Time: 2007-355T19:30:57.282 Stop Time: 2007-355T20:43:43.616
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073552317DNFS01
Start Time: 2007-355T23:17:11.876 Stop Time: 2007-356T03:28:56.949
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073560622DNFS01
Start Time: 2007-356T06:22:12.356 Stop Time: 2007-356T10:27:31.772
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073561256DNFS01
Start Time: 2007-356T12:56:43.563 Stop Time: 2007-356T15:58:06.555
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073561602DNFS01
Start Time: 2007-356T16:02:18.775 Stop Time: 2007-356T17:18:50.299
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073561946DNFS01
Start Time: 2007-356T19:46:25.876 Stop Time: 2007-356T21:35:38.410
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073562241DNFS01
Start Time: 2007-356T22:41:39.211 Stop Time: 2007-357T00:11:02.426
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073570221DNFS01
Start Time: 2007-357T02:21:31.962 Stop Time: 2007-357T02:37:05.809
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073570241DNFS01
Start Time: 2007-357T02:41:16.685 Stop Time: 2007-357T06:50:52.570
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073570944DNFS01
Start Time: 2007-357T09:44:09.362 Stop Time: 2007-357T11:10:51.763
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073571122DNFS01
Start Time: 2007-357T11:22:49.330 Stop Time: 2007-357T13:54:18.527
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073571616DNFS01
Start Time: 2007-357T16:16:33.471 Stop Time: 2007-357T17:36:50.027
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073571858DNFS01
Start Time: 2007-357T18:58:55.490 Stop Time: 2007-357T20:45:59.582
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073572306DNFS01
Start Time: 2007-357T23:06:06.311 Stop Time: 2007-358T03:37:40.833
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073580556DNFS01
Start Time: 2007-358T05:56:11.341 Stop Time: 2007-358T10:12:45.325
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073581306DNFS01
Start Time: 2007-358T13:06:03.416 Stop Time: 2007-358T14:04:21.777
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073582030DNFS01
Start Time: 2007-358T20:30:27.670 Stop Time: 2007-359T00:13:16.674
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073590225DNFS01
Start Time: 2007-359T02:25:54.496 Stop Time: 2007-359T05:32:32.963
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073590536DNFS01
Start Time: 2007-359T05:36:45.276 Stop Time: 2007-359T07:05:03.959
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073590915DNFS01
Start Time: 2007-359T09:15:33.529 Stop Time: 2007-359T13:34:48.605
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073591628DNFS01
Start Time: 2007-359T16:28:03.498 Stop Time: 2007-359T20:48:23.107
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073592255DNFS01
Start Time: 2007-359T22:55:08.240 Stop Time: 2007-360T02:43:54.491
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073600248DNFS01
Start Time: 2007-360T02:48:07.242 Stop Time: 2007-360T03:39:59.788
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073600545DNFS01
Start Time: 2007-360T05:45:08.760 Stop Time: 2007-360T09:49:56.240
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073601655DNFS01
Start Time: 2007-360T16:55:38.270 Stop Time: 2007-360T16:56:36.302
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073601950DNFS01
Start Time: 2007-360T19:50:01.369 Stop Time: 2007-361T00:15:09.946
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073610214DNFS01
Start Time: 2007-361T02:14:26.262 Stop Time: 2007-361T07:06:54.937
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073610904DNFS01
Start Time: 2007-361T09:04:35.003 Stop Time: 2007-361T13:58:40.932
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073611554DNFS01
Start Time: 2007-361T15:54:12.746 Stop Time: 2007-361T20:18:17.665
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073612311DNFS01
Start Time: 2007-361T23:11:44.367 Stop Time: 2007-362T03:42:15.452
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073620534DNFS01
Start Time: 2007-362T05:34:02.829 Stop Time: 2007-362T10:34:02.000
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073621223DNFS01
Start Time: 2007-362T12:23:41.154 Stop Time: 2007-362T15:38:13.708
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073621542DNFS01
Start Time: 2007-362T15:42:26.271 Stop Time: 2007-362T17:25:45.968
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073621913DNFS01
Start Time: 2007-362T19:13:48.905 Stop Time: 2007-362T23:40:34.075
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073630233DNFS01
Start Time: 2007-363T02:33:45.369 Stop Time: 2007-363T07:09:05.580
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073630853DNFS01
Start Time: 2007-363T08:53:24.080 Stop Time: 2007-363T12:09:41.198
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073631213DNFS01
Start Time: 2007-363T12:13:53.012 Stop Time: 2007-363T14:00:56.854
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073631543DNFS01
Start Time: 2007-363T15:43:07.134 Stop Time: 2007-363T20:52:45.651
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073632217DNFS01
Start Time: 2007-363T22:17:49.888 Stop Time: 2007-363T22:33:24.202
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073632237DNFS01
Start Time: 2007-363T22:37:36.609 Stop Time: 2007-364T03:02:12.934
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073640555DNFS01
Start Time: 2007-364T05:55:40.357 Stop Time: 2007-364T09:50:41.833
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073641417DNFS01
Start Time: 2007-364T14:17:15.692 Stop Time: 2007-364T17:28:11.490
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073641902DNFS01
Start Time: 2007-364T19:02:20.801 Stop Time: 2007-365T00:19:28.837
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073650152DNFS01
Start Time: 2007-365T01:52:29.333 Stop Time: 2007-365T06:24:04.656
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073650917DNFS01
Start Time: 2007-365T09:17:32.369 Stop Time: 2007-365T14:19:07.458
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073651802DNFS01
Start Time: 2007-365T18:02:12.617 Stop Time: 2007-365T19:53:28.117
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20073651957DNFS01
Start Time: 2007-365T19:57:40.275 Stop Time: 2008-001T02:43:59.727
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073350014DNFS01
Start Time: 2007-335T00:14:28.803 Stop Time: 2007-335T02:47:05.753
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073350615DNFS01
Start Time: 2007-335T06:15:36.346 Stop Time: 2007-335T09:32:10.624
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073351300DNFS01
Start Time: 2007-335T13:00:41.186 Stop Time: 2007-335T15:17:26.011
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073352034DNFS01
Start Time: 2007-335T20:34:35.608 Stop Time: 2007-335T23:03:27.622
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073360230DNFS01
Start Time: 2007-336T02:30:54.029 Stop Time: 2007-336T05:49:04.090
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073360915DNFS01
Start Time: 2007-336T09:15:58.400 Stop Time: 2007-336T12:30:35.923
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073361705DNFS01
Start Time: 2007-336T17:05:53.629 Stop Time: 2007-336T19:19:45.791
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073370533DNFS01
Start Time: 2007-337T05:33:00.263 Stop Time: 2007-337T08:52:46.854
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073371219DNFS01
Start Time: 2007-337T12:19:41.197 Stop Time: 2007-337T13:00:24.741
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073371304DNFS01
Start Time: 2007-337T13:04:04.399 Stop Time: 2007-337T15:39:54.695
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073371906DNFS01
Start Time: 2007-337T19:06:49.036 Stop Time: 2007-337T22:26:04.029
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073380933DNFS01
Start Time: 2007-338T09:33:26.965 Stop Time: 2007-338T12:01:47.635
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073381527DNFS01
Start Time: 2007-338T15:27:37.853 Stop Time: 2007-338T16:08:04.863
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073381611DNFS01
Start Time: 2007-338T16:11:44.489 Stop Time: 2007-338T18:49:10.694
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073382214DNFS01
Start Time: 2007-338T22:14:28.816 Stop Time: 2007-339T01:37:11.096
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073390140DNFS01
Start Time: 2007-339T01:40:50.847 Stop Time: 2007-339T01:51:27.913
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073390523DNFS01
Start Time: 2007-339T05:23:07.249 Stop Time: 2007-339T08:24:07.896
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073391148DNFS01
Start Time: 2007-339T11:48:21.924 Stop Time: 2007-339T12:28:49.373
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073391232DNFS01
Start Time: 2007-339T12:32:28.624 Stop Time: 2007-339T15:11:31.578
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073391835DNFS01
Start Time: 2007-339T18:35:13.605 Stop Time: 2007-339T19:15:43.334
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073391919DNFS01
Start Time: 2007-339T19:19:22.617 Stop Time: 2007-339T21:58:25.854
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073400122DNFS01
Start Time: 2007-340T01:22:07.788 Stop Time: 2007-340T04:45:39.067
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073400832DNFS01
Start Time: 2007-340T08:32:18.281 Stop Time: 2007-340T11:33:19.612
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073401455DNFS01
Start Time: 2007-340T14:55:57.391 Stop Time: 2007-340T15:36:29.154
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073401540DNFS01
Start Time: 2007-340T15:40:08.655 Stop Time: 2007-340T18:20:47.986
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073402142DNFS01
Start Time: 2007-340T21:42:53.785 Stop Time: 2007-340T22:23:19.795
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073402226DNFS01
Start Time: 2007-340T22:26:59.641 Stop Time: 2007-341T01:07:39.688
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073410429DNFS01
Start Time: 2007-341T04:29:45.404 Stop Time: 2007-341T07:55:25.492
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073411141DNFS01
Start Time: 2007-341T11:41:26.262 Stop Time: 2007-341T14:42:27.407
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073411803DNFS01
Start Time: 2007-341T18:03:29.061 Stop Time: 2007-341T18:44:01.385
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073411847DNFS01
Start Time: 2007-341T18:47:40.636 Stop Time: 2007-341T21:29:56.399
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073420050DNFS01
Start Time: 2007-342T00:50:25.991 Stop Time: 2007-342T01:29:35.375
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073420415DNFS01
Start Time: 2007-342T04:15:05.082 Stop Time: 2007-342T04:16:51.677
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073420737DNFS01
Start Time: 2007-342T07:37:21.265 Stop Time: 2007-342T11:04:57.854
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073421108DNFS01
Start Time: 2007-342T11:08:37.511 Stop Time: 2007-342T11:19:14.483
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073421450DNFS01
Start Time: 2007-342T14:50:48.383 Stop Time: 2007-342T17:51:49.967
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073422111DNFS01
Start Time: 2007-342T21:11:15.433 Stop Time: 2007-342T21:51:38.915
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073422155DNFS01
Start Time: 2007-342T21:55:19.728 Stop Time: 2007-343T00:39:12.305
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073430640DNFS01
Start Time: 2007-343T06:40:15.411 Stop Time: 2007-343T07:26:26.736
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073431044DNFS01
Start Time: 2007-343T10:44:47.984 Stop Time: 2007-343T14:13:41.299
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073431800DNFS01
Start Time: 2007-343T18:00:02.246 Stop Time: 2007-343T19:56:44.908
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073440714DNFS01
Start Time: 2007-344T07:14:51.385 Stop Time: 2007-344T10:37:19.005
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073441356DNFS01
Start Time: 2007-344T13:56:12.409 Stop Time: 2007-344T16:33:34.424
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073442258DNFS01
Start Time: 2007-344T22:58:15.410 Stop Time: 2007-345T00:15:51.871
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073450333DNFS01
Start Time: 2007-345T03:33:41.087 Stop Time: 2007-345T07:04:43.364
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073451022DNFS01
Start Time: 2007-345T10:22:32.614 Stop Time: 2007-345T10:39:03.180
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073451226DNFS01
Start Time: 2007-345T12:26:06.992 Stop Time: 2007-345T13:53:54.371
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073451711DNFS01
Start Time: 2007-345T17:11:11.583 Stop Time: 2007-345T20:43:46.273
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073452047DNFS01
Start Time: 2007-345T20:47:25.523 Stop Time: 2007-345T20:58:02.558
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073460031DNFS01
Start Time: 2007-346T00:31:24.371 Stop Time: 2007-346T03:32:25.985
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073460648DNFS01
Start Time: 2007-346T06:48:39.072 Stop Time: 2007-346T07:29:16.085
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073460732DNFS01
Start Time: 2007-346T07:32:55.679 Stop Time: 2007-346T07:38:03.243
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073462137DNFS01
Start Time: 2007-346T21:37:58.342 Stop Time: 2007-346T23:59:39.665
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073470347DNFS01
Start Time: 2007-347T03:47:57.250 Stop Time: 2007-347T06:48:59.021
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073471004DNFS01
Start Time: 2007-347T10:04:07.986 Stop Time: 2007-347T13:38:23.526
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073471652DNFS01
Start Time: 2007-347T16:52:28.293 Stop Time: 2007-347T17:33:00.022
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073471736DNFS01
Start Time: 2007-347T17:36:39.524 Stop Time: 2007-347T20:27:30.102
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073472341DNFS01
Start Time: 2007-347T23:41:02.813 Stop Time: 2007-348T03:16:22.216
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073480910DNFS01
Start Time: 2007-348T09:10:26.949 Stop Time: 2007-348T10:05:31.965
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073481318DNFS01
Start Time: 2007-348T13:18:32.619 Stop Time: 2007-348T13:59:11.226
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073481402DNFS01
Start Time: 2007-348T14:02:51.039 Stop Time: 2007-348T15:09:28.311
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073482308DNFS01
Start Time: 2007-348T23:08:15.675 Stop Time: 2007-348T23:44:03.968
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073490256DNFS01
Start Time: 2007-349T02:56:00.524 Stop Time: 2007-349T06:33:24.959
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073490637DNFS01
Start Time: 2007-349T06:37:04.512 Stop Time: 2007-349T06:47:41.579
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073491021DNFS01
Start Time: 2007-349T10:21:09.241 Stop Time: 2007-349T13:22:10.983
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073491633DNFS01
Start Time: 2007-349T16:33:35.507 Stop Time: 2007-349T17:14:07.207
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073491717DNFS01
Start Time: 2007-349T17:17:47.021 Stop Time: 2007-349T20:11:18.321
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073492322DNFS01
Start Time: 2007-349T23:22:10.751 Stop Time: 2007-350T03:00:10.687
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073500611DNFS01
Start Time: 2007-350T06:11:03.122 Stop Time: 2007-350T09:49:35.398
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073501337DNFS01
Start Time: 2007-350T13:37:45.372 Stop Time: 2007-350T16:38:47.865
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073501948DNFS01
Start Time: 2007-350T19:48:36.173 Stop Time: 2007-350T21:04:03.789
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073510238DNFS01
Start Time: 2007-351T02:38:31.774 Stop Time: 2007-351T06:18:08.713
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073510929DNFS01
Start Time: 2007-351T09:29:01.239 Stop Time: 2007-351T13:08:37.512
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073511654DNFS01
Start Time: 2007-351T16:54:13.365 Stop Time: 2007-351T20:39:11.743
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073512339DNFS01
Start Time: 2007-351T23:39:22.955 Stop Time: 2007-352T03:30:46.583
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073520628DNFS01
Start Time: 2007-352T06:28:49.566 Stop Time: 2007-352T07:08:02.515
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073520717DNFS01
Start Time: 2007-352T07:17:35.454 Stop Time: 2007-352T10:22:54.383
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073521318DNFS01
Start Time: 2007-352T13:18:49.059 Stop Time: 2007-352T17:23:04.626
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073522016DNFS01
Start Time: 2007-352T20:16:19.241 Stop Time: 2007-352T20:39:15.592
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073522059DNFS01
Start Time: 2007-352T20:59:19.223 Stop Time: 2007-353T00:06:38.060
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073530258DNFS01
Start Time: 2007-353T02:58:48.302 Stop Time: 2007-353T05:52:16.885
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073530555DNFS01
Start Time: 2007-353T05:55:56.418 Stop Time: 2007-353T06:58:00.091
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073530948DNFS01
Start Time: 2007-353T09:48:34.139 Stop Time: 2007-353T09:52:45.265
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073531157DNFS01
Start Time: 2007-353T11:57:10.425 Stop Time: 2007-353T13:49:36.052
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073531623DNFS01
Start Time: 2007-353T16:23:36.157 Stop Time: 2007-353T16:38:48.536
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073531642DNFS01
Start Time: 2007-353T16:42:27.912 Stop Time: 2007-353T17:49:20.618
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073531753DNFS01
Start Time: 2007-353T17:53:43.901 Stop Time: 2007-353T20:45:06.731
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073532338DNFS01
Start Time: 2007-353T23:38:20.363 Stop Time: 2007-354T03:33:29.276
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073540618DNFS01
Start Time: 2007-354T06:18:10.636 Stop Time: 2007-354T09:21:20.345
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073542114DNFS01
Start Time: 2007-354T21:14:18.862 Stop Time: 2007-355T00:06:46.038
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073550300DNFS01
Start Time: 2007-355T03:00:17.243 Stop Time: 2007-355T07:00:15.626
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073550937DNFS01
Start Time: 2007-355T09:37:28.112 Stop Time: 2007-355T13:52:26.123
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073551627DNFS01
Start Time: 2007-355T16:27:30.353 Stop Time: 2007-355T19:26:47.469
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073551930DNFS01
Start Time: 2007-355T19:30:26.907 Stop Time: 2007-355T20:43:45.709
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073552317DNFS01
Start Time: 2007-355T23:17:13.751 Stop Time: 2007-356T03:28:59.043
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073560622DNFS01
Start Time: 2007-356T06:22:14.231 Stop Time: 2007-356T10:27:33.865
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073561256DNFS01
Start Time: 2007-356T12:56:45.438 Stop Time: 2007-356T15:58:08.649
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073561601DNFS01
Start Time: 2007-356T16:01:48.369 Stop Time: 2007-356T17:18:52.393
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073561946DNFS01
Start Time: 2007-356T19:46:27.751 Stop Time: 2007-356T21:35:40.504
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073562241DNFS01
Start Time: 2007-356T22:41:41.086 Stop Time: 2007-357T00:11:04.519
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073570221DNFS01
Start Time: 2007-357T02:21:33.837 Stop Time: 2007-357T02:37:07.903
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073570240DNFS01
Start Time: 2007-357T02:40:46.341 Stop Time: 2007-357T06:50:54.664
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073570944DNFS01
Start Time: 2007-357T09:44:11.237 Stop Time: 2007-357T11:10:53.857
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073571122DNFS01
Start Time: 2007-357T11:22:51.205 Stop Time: 2007-357T13:54:20.620
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073571616DNFS01
Start Time: 2007-357T16:16:35.346 Stop Time: 2007-357T17:36:52.121
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073571858DNFS01
Start Time: 2007-357T18:58:57.365 Stop Time: 2007-357T20:46:01.676
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073572306DNFS01
Start Time: 2007-357T23:06:08.186 Stop Time: 2007-358T03:37:42.927
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073580556DNFS01
Start Time: 2007-358T05:56:13.216 Stop Time: 2007-358T10:12:47.419
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073581306DNFS01
Start Time: 2007-358T13:06:05.291 Stop Time: 2007-358T14:04:23.871
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073582030DNFS01
Start Time: 2007-358T20:30:29.545 Stop Time: 2007-359T00:13:18.768
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073590225DNFS01
Start Time: 2007-359T02:25:56.371 Stop Time: 2007-359T05:32:35.057
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073590536DNFS01
Start Time: 2007-359T05:36:14.901 Stop Time: 2007-359T07:05:06.053
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073590915DNFS01
Start Time: 2007-359T09:15:35.404 Stop Time: 2007-359T13:34:50.698
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073591628DNFS01
Start Time: 2007-359T16:28:05.373 Stop Time: 2007-359T20:48:25.201
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073592255DNFS01
Start Time: 2007-359T22:55:10.115 Stop Time: 2007-360T02:43:56.584
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073600247DNFS01
Start Time: 2007-360T02:47:36.867 Stop Time: 2007-360T03:40:01.881
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073600545DNFS01
Start Time: 2007-360T05:45:10.635 Stop Time: 2007-360T09:49:58.334
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073601655DNFS01
Start Time: 2007-360T16:55:40.145 Stop Time: 2007-360T16:56:38.396
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073601950DNFS01
Start Time: 2007-360T19:50:03.244 Stop Time: 2007-361T00:15:12.039
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073610214DNFS01
Start Time: 2007-361T02:14:28.137 Stop Time: 2007-361T07:06:57.031
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073610904DNFS01
Start Time: 2007-361T09:04:36.878 Stop Time: 2007-361T13:58:43.025
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073611554DNFS01
Start Time: 2007-361T15:54:14.621 Stop Time: 2007-361T20:18:19.759
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073612311DNFS01
Start Time: 2007-361T23:11:46.242 Stop Time: 2007-362T03:42:17.546
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073620534DNFS01
Start Time: 2007-362T05:34:04.704 Stop Time: 2007-362T10:34:04.094
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073621223DNFS01
Start Time: 2007-362T12:23:43.029 Stop Time: 2007-362T15:38:15.802
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073621541DNFS01
Start Time: 2007-362T15:41:55.896 Stop Time: 2007-362T17:25:48.062
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073621913DNFS01
Start Time: 2007-362T19:13:50.780 Stop Time: 2007-362T23:40:36.168
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073630233DNFS01
Start Time: 2007-363T02:33:47.244 Stop Time: 2007-363T07:09:07.674
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073630853DNFS01
Start Time: 2007-363T08:53:25.955 Stop Time: 2007-363T12:09:43.292
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073631213DNFS01
Start Time: 2007-363T12:13:22.387 Stop Time: 2007-363T14:00:58.948
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073631543DNFS01
Start Time: 2007-363T15:43:09.009 Stop Time: 2007-363T20:52:47.745
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073632217DNFS01
Start Time: 2007-363T22:17:51.763 Stop Time: 2007-363T22:33:26.296
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073632237DNFS01
Start Time: 2007-363T22:37:06.202 Stop Time: 2007-364T03:02:15.028
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073640555DNFS01
Start Time: 2007-364T05:55:42.232 Stop Time: 2007-364T09:50:43.926
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073641417DNFS01
Start Time: 2007-364T14:17:17.567 Stop Time: 2007-364T17:28:13.584
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073641902DNFS01
Start Time: 2007-364T19:02:22.676 Stop Time: 2007-365T00:19:30.930
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073650152DNFS01
Start Time: 2007-365T01:52:31.208 Stop Time: 2007-365T06:24:06.750
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073650917DNFS01
Start Time: 2007-365T09:17:34.244 Stop Time: 2007-365T14:19:09.552
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073651802DNFS01
Start Time: 2007-365T18:02:14.492 Stop Time: 2007-365T19:53:30.211
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20073651957DNFS01
Start Time: 2007-365T19:57:09.900 Stop Time: 2008-001T02:44:01.821
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench