• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Mars Express >> ASPERA-3
VOLUME 1: MARS EXPRESS ASPERA3 EDR IMA DATA View Errata Order Volume Toggle viewing into expanded mode
MEX-M-ASPERA3-2-EDR-IMA-EXT5-V1.0 PDS 3      CERTIFIED
Start Time: 2015-01-01 08:00:00
VOLUME 1: MARS EXPRESS ASPERA3 EDR IMA DATA
VOLUME 1: MARS EXPRESS ASPERA3 EDR IMA DATA
Citiation Information
Lundin, R., S. Barabash, D. Winningham, R. Frahm, MARS EXPRESS ASPERA-3 RAW EDR ION MASS ANALYZER EXT5 V1.0, MEX-M-ASPERA3-2-EDR-IMA-EXT5-V1.0, ESA Planetary Science Archive (PSA), NASA Planetary Data System (PDS), 2006
Top/ DATA/ 2016/ 275_305OCT / click here to download folders and files
IMA_AZ0020162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162751016C_ACCS01
Start Time: 2016-275T10:16:15.725 Stop Time: 2016-276T00:00:05.902
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162760000C_ACCS01
Start Time: 2016-275T23:59:54.296 Stop Time: 2016-276T11:06:19.561
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162761415C_ACCS01
Start Time: 2016-276T14:15:09.700 Stop Time: 2016-277T00:00:33.814
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162770000C_ACCS01
Start Time: 2016-277T00:00:22.207 Stop Time: 2016-277T04:50:12.377
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162770744C_ACCS01
Start Time: 2016-277T07:44:39.673 Stop Time: 2016-277T15:05:14.567
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162771814C_ACCS01
Start Time: 2016-277T18:14:07.737 Stop Time: 2016-277T22:56:01.287
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162780133C_ACCS01
Start Time: 2016-278T01:33:33.145 Stop Time: 2016-278T01:36:44.288
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162790331C_ACCS01
Start Time: 2016-279T03:31:11.745 Stop Time: 2016-279T22:53:28.704
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162800211C_ACCS01
Start Time: 2016-280T02:11:49.781 Stop Time: 2016-280T23:59:28.147
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162802359C_ACCS01
Start Time: 2016-280T23:59:16.541 Stop Time: 2016-281T03:01:53.679
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162810610C_ACCS01
Start Time: 2016-281T06:10:45.756 Stop Time: 2016-281T23:59:58.121
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162812359C_ACCS01
Start Time: 2016-281T23:59:46.515 Stop Time: 2016-282T07:00:49.717
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162821009C_ACCS01
Start Time: 2016-282T10:09:39.793 Stop Time: 2016-282T23:59:54.064
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162822359C_ACCS01
Start Time: 2016-282T23:59:42.458 Stop Time: 2016-283T04:21:00.346
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162830424C_ACCS01
Start Time: 2016-283T04:24:13.235 Stop Time: 2016-283T06:53:17.566
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162830913C_ACCS01
Start Time: 2016-283T09:13:51.767 Stop Time: 2016-283T10:59:27.817
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162831408C_ACCS01
Start Time: 2016-283T14:08:31.768 Stop Time: 2016-284T00:00:19.976
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162840000C_ACCS01
Start Time: 2016-284T00:00:08.369 Stop Time: 2016-284T07:58:48.040
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162841107C_ACCS01
Start Time: 2016-284T11:07:47.804 Stop Time: 2016-284T23:59:05.575
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162842359C_ACCS01
Start Time: 2016-284T23:58:53.968 Stop Time: 2016-285T11:57:19.671
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162851506C_ACCS01
Start Time: 2016-285T15:06:37.810 Stop Time: 2016-285T23:58:09.486
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162852358C_ACCS01
Start Time: 2016-285T23:57:57.880 Stop Time: 2016-286T15:56:09.646
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162861905C_ACCS01
Start Time: 2016-286T19:05:33.816 Stop Time: 2016-286T23:59:43.398
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162862359C_ACCS01
Start Time: 2016-286T23:59:31.791 Stop Time: 2016-287T12:55:18.026
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162871604C_ACCS01
Start Time: 2016-287T16:04:44.915 Stop Time: 2016-287T23:58:56.091
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162872358C_ACCS01
Start Time: 2016-287T23:58:44.484 Stop Time: 2016-288T09:54:29.155
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162881303C_ACCS01
Start Time: 2016-288T13:03:57.826 Stop Time: 2016-289T00:00:02.533
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162890000C_ACCS01
Start Time: 2016-288T23:59:50.927 Stop Time: 2016-289T13:53:29.693
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162891702C_ACCS01
Start Time: 2016-289T17:02:51.832 Stop Time: 2016-289T23:59:10.507
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162892359C_ACCS01
Start Time: 2016-289T23:58:58.901 Stop Time: 2016-290T10:52:36.135
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162901402C_ACCS01
Start Time: 2016-290T14:02:05.774 Stop Time: 2016-291T00:00:34.075
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162910000C_ACCS01
Start Time: 2016-291T00:00:22.468 Stop Time: 2016-291T01:49:22.950
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162910158C_ACCS01
Start Time: 2016-291T01:58:59.901 Stop Time: 2016-291T07:51:50.108
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162911101C_ACCS01
Start Time: 2016-291T11:01:19.841 Stop Time: 2016-291T23:59:01.611
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162912359C_ACCS01
Start Time: 2016-291T23:58:50.005 Stop Time: 2016-292T11:50:35.739
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162921500C_ACCS01
Start Time: 2016-292T15:00:11.847 Stop Time: 2016-292T23:58:07.585
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162922358C_ACCS01
Start Time: 2016-292T23:57:55.979 Stop Time: 2016-293T00:46:07.898
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162931844C_ACCS01
Start Time: 2016-293T18:44:03.790 Stop Time: 2016-293T23:59:33.528
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162932359C_ACCS01
Start Time: 2016-293T23:59:21.921 Stop Time: 2016-294T09:23:54.436
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162941558C_ACCS01
Start Time: 2016-294T15:58:15.763 Stop Time: 2016-294T22:28:26.158
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162950157C_ACCS01
Start Time: 2016-295T01:57:57.797 Stop Time: 2016-295T09:48:08.973
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162951637C_ACCS01
Start Time: 2016-295T16:37:27.706 Stop Time: 2016-295T23:59:54.726
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162952359C_ACCS01
Start Time: 2016-295T23:59:43.119 Stop Time: 2016-296T06:47:10.165
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162961401C_ACCS01
Start Time: 2016-296T14:01:33.742 Stop Time: 2016-296T23:26:25.731
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162970256C_ACCS01
Start Time: 2016-297T02:56:05.839 Stop Time: 2016-297T06:30:30.763
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162970636C_ACCS01
Start Time: 2016-297T06:36:39.683 Stop Time: 2016-297T10:46:16.952
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162971715C_ACCS01
Start Time: 2016-297T17:15:31.748 Stop Time: 2016-298T00:00:22.424
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162980000C_ACCS01
Start Time: 2016-298T00:00:10.817 Stop Time: 2016-298T07:45:14.394
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162981554C_ACCS01
Start Time: 2016-298T15:54:35.847 Stop Time: 2016-298T23:58:54.991
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162982358C_ACCS01
Start Time: 2016-298T23:58:43.385 Stop Time: 2016-299T00:24:31.210
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162990334C_ACCS01
Start Time: 2016-299T03:34:07.755 Stop Time: 2016-299T11:44:03.181
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520162991858C_ACCS01
Start Time: 2016-299T18:58:41.790 Stop Time: 2016-300T00:01:07.559
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163000001C_ACCS01
Start Time: 2016-300T00:00:55.952 Stop Time: 2016-300T03:19:33.216
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163001632C_ACCS01
Start Time: 2016-300T16:32:43.826 Stop Time: 2016-300T23:59:26.751
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163002359C_ACCS01
Start Time: 2016-300T23:59:15.145 Stop Time: 2016-301T04:38:41.127
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163010852C_ACCS01
Start Time: 2016-301T08:52:03.798 Stop Time: 2016-301T12:19:48.660
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163011501C_ACCS01
Start Time: 2016-301T15:01:43.831 Stop Time: 2016-301T23:58:35.538
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163012358C_ACCS01
Start Time: 2016-301T23:58:23.931 Stop Time: 2016-302T05:18:22.258
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163021750C_ACCS01
Start Time: 2016-302T17:50:53.774 Stop Time: 2016-303T00:00:00.043
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163030000C_ACCS01
Start Time: 2016-302T23:59:48.437 Stop Time: 2016-303T13:40:23.109
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163031649C_ACCS01
Start Time: 2016-303T16:49:49.873 Stop Time: 2016-303T23:58:56.673
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163032358C_ACCS01
Start Time: 2016-303T23:58:45.067 Stop Time: 2016-304T10:39:34.176
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163041348C_ACCS01
Start Time: 2016-304T13:48:59.908 Stop Time: 2016-305T00:00:32.210
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163050000C_ACCS01
Start Time: 2016-305T00:00:20.603 Stop Time: 2016-305T07:38:44.118
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520163051048C_ACCS01
Start Time: 2016-305T10:48:17.850 Stop Time: 2016-305T13:34:42.465
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench