MEX-M-ASPERA3-2-EDR-IMA-EXT5-V1.0 PDS 3      CERTIFIED
Start Time: 2015-01-01 08:00:00
Extension 5 data from the Ion Mass Analyzer (IMA) instrument of the Analyzer of Space Plasmas and Energetic Atoms experiment, 3rd edition (ASPERA-3), aboard the Mars Express spacecraft. The ASPERA-3 Principal Investigator is Dr. Rickard Lundin, Swedish Institute of Space Physics (IRF), Kiruna, Sweden. The primary source for ASPERA-3 data     more ...
Extension 5 data from the Ion Mass Analyzer (IMA) instrument of the Analyzer of Space Plasmas and Energetic Atoms experiment, 3rd edition (ASPERA-3), aboard the Mars Express spacecraft. The ASPERA-3 Principal Investigator is Dr. Rickard Lundin, Swedish Institute of Space Physics (IRF), Kiruna, Sweden. The primary source for ASPERA-3 data is the ESA Planetary Science Archive (PSA).    less ...
Citiation Information
Lundin, R., S. Barabash, D. Winningham, R. Frahm, MARS EXPRESS ASPERA-3 RAW EDR ION MASS ANALYZER EXT5 V1.0, MEX-M-ASPERA3-2-EDR-IMA-EXT5-V1.0, ESA Planetary Science Archive (PSA), NASA Planetary Data System (PDS), 2006
Top/ DATA/ 2015/ 060_090MAR / click here to download folders and files
IMA_AZ0020150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0020150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ0:  Ion Mass Analyzer AZimuth
anode 0.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0120150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ1:  Ion Mass Analyzer AZimuth
anode 1.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0220150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ2:  Ion Mass Analyzer AZimuth
anode 2.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0320150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ3:  Ion Mass Analyzer AZimuth
anode 3.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0420150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ4:  Ion Mass Analyzer AZimuth
anode 4.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0520150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ5:  Ion Mass Analyzer AZimuth
anode 5.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0620150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ6:  Ion Mass Analyzer AZimuth
anode 6.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0720150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ7:  Ion Mass Analyzer AZimuth
anode 7.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0820150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ8:  Ion Mass Analyzer AZimuth
anode 8.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ0920150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ9:  Ion Mass Analyzer AZimuth
anode 9.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1020150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ10:  Ion Mass Analyzer AZimuth
anode 10.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1120150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ11:  Ion Mass Analyzer AZimuth
anode 11.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1220150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ12:  Ion Mass Analyzer AZimuth
anode 12.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1320150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ13:  Ion Mass Analyzer AZimuth
anode 13.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1420150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ14:  Ion Mass Analyzer AZimuth
anode 14.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150601955C_ACCS01
Start Time: 2015-060T19:55:02.870 Stop Time: 2015-060T23:40:23.889
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150610249C_ACCS01
Start Time: 2015-061T02:49:58.028 Stop Time: 2015-062T00:00:00.050
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150620000C_ACCS01
Start Time: 2015-061T23:59:48.443 Stop Time: 2015-062T03:38:41.957
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150620647C_ACCS01
Start Time: 2015-062T06:47:52.096 Stop Time: 2015-062T13:52:42.834
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150621617C_ACCS01
Start Time: 2015-062T16:17:26.035 Stop Time: 2015-062T23:58:49.086
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150622358C_ACCS01
Start Time: 2015-062T23:58:37.479 Stop Time: 2015-063T07:36:44.962
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150631045C_ACCS01
Start Time: 2015-063T10:45:48.039 Stop Time: 2015-063T19:52:15.840
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150631958C_ACCS01
Start Time: 2015-063T19:58:40.822 Stop Time: 2015-063T20:08:16.027
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150632017C_ACCS01
Start Time: 2015-063T20:17:53.009 Stop Time: 2015-063T23:59:45.966
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150632359C_ACCS01
Start Time: 2015-063T23:59:34.359 Stop Time: 2015-064T11:34:47.968
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150641443C_ACCS01
Start Time: 2015-064T14:43:52.013 Stop Time: 2015-064T23:59:55.877
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150642359C_ACCS01
Start Time: 2015-064T23:59:44.270 Stop Time: 2015-065T01:33:48.721
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150650442C_ACCS01
Start Time: 2015-065T04:42:50.078 Stop Time: 2015-065T23:58:43.038
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150652358C_ACCS01
Start Time: 2015-065T23:58:31.431 Stop Time: 2015-066T05:31:33.914
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150660840C_ACCS01
Start Time: 2015-066T08:40:48.084 Stop Time: 2015-066T19:30:44.760
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150662239C_ACCS01
Start Time: 2015-066T22:39:46.024 Stop Time: 2015-066T23:59:45.918
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150662359C_ACCS01
Start Time: 2015-066T23:59:34.311 Stop Time: 2015-067T08:54:30.451
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150670904C_ACCS01
Start Time: 2015-067T09:04:07.433 Stop Time: 2015-067T23:28:45.954
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150680237C_ACCS01
Start Time: 2015-068T02:37:44.030 Stop Time: 2015-068T20:52:48.614
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150682056C_ACCS01
Start Time: 2015-068T20:56:01.534 Stop Time: 2015-069T00:00:50.146
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150690000C_ACCS01
Start Time: 2015-069T00:00:38.540 Stop Time: 2015-069T01:24:02.959
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150690133C_ACCS01
Start Time: 2015-069T01:33:39.910 Stop Time: 2015-069T01:36:51.053
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150690149C_ACCS01
Start Time: 2015-069T01:49:39.972 Stop Time: 2015-069T01:52:51.115
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150690205C_ACCS01
Start Time: 2015-069T02:05:40.097 Stop Time: 2015-069T03:26:43.959
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150690635C_ACCS01
Start Time: 2015-069T06:35:40.098 Stop Time: 2015-069T08:27:40.147
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150690846C_ACCS01
Start Time: 2015-069T08:46:53.161 Stop Time: 2015-069T08:50:04.304
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150690859C_ACCS01
Start Time: 2015-069T08:59:41.255 Stop Time: 2015-069T15:45:03.899
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150691557C_ACCS01
Start Time: 2015-069T15:57:52.850 Stop Time: 2015-069T23:59:32.119
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150692359C_ACCS01
Start Time: 2015-069T23:59:20.513 Stop Time: 2015-070T07:24:23.902
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150701033C_ACCS01
Start Time: 2015-070T10:33:40.041 Stop Time: 2015-071T00:00:26.355
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150710000C_ACCS01
Start Time: 2015-071T00:00:22.487 Stop Time: 2015-071T03:08:12.012
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150710311C_ACCS01
Start Time: 2015-071T03:11:24.638 Stop Time: 2015-071T11:22:24.264
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150711431C_ACCS01
Start Time: 2015-071T14:31:26.109 Stop Time: 2015-072T00:00:18.067
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150720000C_ACCS01
Start Time: 2015-072T00:00:06.460 Stop Time: 2015-072T01:21:22.755
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150720430C_ACCS01
Start Time: 2015-072T04:30:28.050 Stop Time: 2015-072T08:40:05.287
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150720905C_ACCS01
Start Time: 2015-072T09:05:42.488 Stop Time: 2015-072T09:08:53.631
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150721016C_ACCS01
Start Time: 2015-072T10:16:06.989 Stop Time: 2015-072T10:19:18.131
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150721025C_ACCS01
Start Time: 2015-072T10:25:43.145 Stop Time: 2015-072T10:28:54.288
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150721057C_ACCS01
Start Time: 2015-072T10:57:43.426 Stop Time: 2015-072T11:00:54.569
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150721445C_ACCS01
Start Time: 2015-072T14:45:13.302 Stop Time: 2015-072T23:59:09.197
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150722359C_ACCS01
Start Time: 2015-072T23:58:57.590 Stop Time: 2015-073T05:19:11.948
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150730828C_ACCS01
Start Time: 2015-073T08:28:22.056 Stop Time: 2015-073T19:18:18.763
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150732227C_ACCS01
Start Time: 2015-073T22:27:22.121 Stop Time: 2015-074T00:00:09.983
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150740000C_ACCS01
Start Time: 2015-073T23:59:58.377 Stop Time: 2015-074T12:22:08.361
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150741225C_ACCS01
Start Time: 2015-074T12:25:21.280 Stop Time: 2015-074T23:16:21.957
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150750225C_ACCS01
Start Time: 2015-075T02:25:16.064 Stop Time: 2015-075T23:13:41.927
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150752319C_ACCS01
Start Time: 2015-075T23:19:34.878 Stop Time: 2015-076T00:01:10.333
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150760001C_ACCS01
Start Time: 2015-076T00:00:58.727 Stop Time: 2015-076T03:14:15.959
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150760623C_ACCS01
Start Time: 2015-076T06:23:16.160 Stop Time: 2015-076T23:59:56.244
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150762359C_ACCS01
Start Time: 2015-076T23:59:44.638 Stop Time: 2015-077T06:13:19.495
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150770616C_ACCS01
Start Time: 2015-077T06:16:32.384 Stop Time: 2015-077T07:11:59.933
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150771021C_ACCS01
Start Time: 2015-077T10:21:08.166 Stop Time: 2015-078T00:00:42.280
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150780000C_ACCS01
Start Time: 2015-078T00:00:30.674 Stop Time: 2015-078T08:25:50.563
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150780829C_ACCS01
Start Time: 2015-078T08:29:03.451 Stop Time: 2015-078T11:10:08.001
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150781419C_ACCS01
Start Time: 2015-078T14:19:12.171 Stop Time: 2015-079T00:00:52.222
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150790000C_ACCS01
Start Time: 2015-079T00:00:40.616 Stop Time: 2015-079T15:07:55.944
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150791817C_ACCS01
Start Time: 2015-079T18:17:00.145 Stop Time: 2015-079T23:59:26.164
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150792359C_ACCS01
Start Time: 2015-079T23:59:14.558 Stop Time: 2015-080T05:06:56.822
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150800816C_ACCS01
Start Time: 2015-080T08:16:02.086 Stop Time: 2015-080T23:59:37.357
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150802359C_ACCS01
Start Time: 2015-080T23:59:25.750 Stop Time: 2015-081T02:05:30.451
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150810514C_ACCS01
Start Time: 2015-081T05:14:28.121 Stop Time: 2015-081T13:36:07.547
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150811339C_ACCS01
Start Time: 2015-081T13:39:20.466 Stop Time: 2015-081T14:33:44.016
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150811443C_ACCS01
Start Time: 2015-081T14:43:20.998 Stop Time: 2015-081T21:07:39.361
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150812117C_ACCS01
Start Time: 2015-081T21:17:16.343 Stop Time: 2015-081T21:20:27.486
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150812130C_ACCS01
Start Time: 2015-081T21:30:04.437 Stop Time: 2015-081T21:33:15.580
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150812142C_ACCS01
Start Time: 2015-081T21:42:52.593 Stop Time: 2015-081T23:03:40.361
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150820537C_ACCS01
Start Time: 2015-082T05:37:58.094 Stop Time: 2015-082T23:58:22.679
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150822358C_ACCS01
Start Time: 2015-082T23:58:11.072 Stop Time: 2015-083T03:01:52.148
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150830611C_ACCS01
Start Time: 2015-083T06:11:02.162 Stop Time: 2015-083T08:25:26.462
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150830835C_ACCS01
Start Time: 2015-083T08:35:03.413 Stop Time: 2015-084T00:00:30.402
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150840000C_ACCS01
Start Time: 2015-084T00:00:18.796 Stop Time: 2015-084T02:59:43.934
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150840305C_ACCS01
Start Time: 2015-084T03:05:20.823 Stop Time: 2015-084T07:00:01.966
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150841009C_ACCS01
Start Time: 2015-084T10:09:10.105 Stop Time: 2015-084T21:05:30.875
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150842108C_ACCS01
Start Time: 2015-084T21:08:43.764 Stop Time: 2015-084T23:58:20.376
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150842358C_ACCS01
Start Time: 2015-084T23:58:08.769 Stop Time: 2015-085T10:58:10.035
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150851407C_ACCS01
Start Time: 2015-085T14:07:16.205 Stop Time: 2015-085T16:56:52.755
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150851700C_ACCS01
Start Time: 2015-085T17:00:05.674 Stop Time: 2015-085T23:58:32.319
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150852358C_ACCS01
Start Time: 2015-085T23:58:20.712 Stop Time: 2015-086T00:57:12.881
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150860406C_ACCS01
Start Time: 2015-086T04:06:26.114 Stop Time: 2015-086T07:44:03.164
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150870104C_ACCS01
Start Time: 2015-087T01:04:58.119 Stop Time: 2015-087T11:54:54.733
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150871504C_ACCS01
Start Time: 2015-087T15:04:03.340 Stop Time: 2015-088T00:00:55.016
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150880000C_ACCS01
Start Time: 2015-088T00:00:43.410 Stop Time: 2015-088T04:53:13.455
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150880459C_ACCS01
Start Time: 2015-088T04:59:06.437 Stop Time: 2015-088T08:53:47.518
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150881202C_ACCS01
Start Time: 2015-088T12:02:43.376 Stop Time: 2015-088T22:52:40.052
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150890201C_ACCS01
Start Time: 2015-089T02:01:46.129 Stop Time: 2015-090T00:00:04.589
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150900000C_ACCS01
Start Time: 2015-089T23:59:52.982 Stop Time: 2015-090T02:50:46.058
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150900600C_ACCS01
Start Time: 2015-090T06:00:02.166 Stop Time: 2015-090T19:49:12.374
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150901954C_ACCS01
Start Time: 2015-090T19:54:49.388 Stop Time: 2015-090T23:59:06.500
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
IMA_AZ1520150902359C_ACCS01
Start Time: 2015-090T23:58:54.894 Stop Time: 2015-091T02:48:44.032
This file contains data from IMA_AZ15:  Ion Mass Analyzer AZimuth
anode 15.  Each IMA anode (or sector) collects data for the 32
mass channels (SENSOR rows) at 96 energy steps from 0.01-40 keV.
The center energy for each step is found in the IMA_ENERGYn.TAB
files in the CALIB directory. Which table to use is based on the
time period (documented in the CALINFO.TXT and in the labels).
The last 96 values in each SENSOR row are the data values (c/acc)
sampled at each energy step. The energy steps are indexed starting
at 0, so the last value is at energy index 95.  To get the center
energy in eV, use the corresponding eV value for the energy index
found in the appropriate ENERGY calibration table in the CALIB
directory.  The data values are formatted for better processing
accuracy and DO NOT reflect the accuracy of the instrumentation.
Please refer to the Data Set Catalog, ASPERA3_EDR_IMA_DS.CAT, for
details about data organization, science meaning, data modes, etc.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench