• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Mars Express >> ASPERA-3
VOLUME 1: MARS EXPRESS ASPERA3 EDR ELS DATA View Errata Order Volume Toggle viewing into brief mode
MEX-M-ASPERA3-2-EDR-ELS-EXT2-V1.0 PDS 3      CERTIFIED
Start Time: 2007-10-01 18:38:48 - Stop Time: 2010-01-01 15:14:19
Extension 2 raw data from the Electron Spectrometer (ELS) instrument of the Analyzer of Space Plasmas and Energetic Atoms experiment, 3rd edition (ASPERA-3), aboard the Mars Express spacecraft. The ASPERA-3 Principal Investigator is Dr. Rickard Lundin, Swedish Institute of Space Physics (IRF), Kiruna, Sweden. The primary source for ASPERA-3 data     more ...
Extension 2 raw data from the Electron Spectrometer (ELS) instrument of the Analyzer of Space Plasmas and Energetic Atoms experiment, 3rd edition (ASPERA-3), aboard the Mars Express spacecraft. The ASPERA-3 Principal Investigator is Dr. Rickard Lundin, Swedish Institute of Space Physics (IRF), Kiruna, Sweden. The primary source for ASPERA-3 data is the ESA Planetary Science Archive (PSA).    less ...
Citiation Information
Lundin, R., S. Barabash, D. Winningham, R. Frahm, MARS EXPRESS ASPERA-3 RAW EDR ELECTRON SPECTROMTR EXT2 V1.0, MEX-M-ASPERA3-2-EDR-ELS-EXT2-V1.0, ESA Planetary Science Archive (PSA), NASA Planetary Data System (PDS), 2005
Top/ DATA/ 2008/ 092_121APR / click here to download folders and files
ELSSCIH20080920305C_ACCS01
Start Time: 2008-092T03:05:20.538 Stop Time: 2008-092T11:31:33.441
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20080921135C_ACCS01
Start Time: 2008-092T11:35:45.847 Stop Time: 2008-092T15:08:24.035
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20080941800C_ACCS01
Start Time: 2008-094T18:00:46.047 Stop Time: 2008-094T19:40:52.141
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20080942306C_ACCS01
Start Time: 2008-094T23:06:05.168 Stop Time: 2008-095T04:36:44.666
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20080960409C_ACCS01
Start Time: 2008-096T04:09:47.425 Stop Time: 2008-096T11:18:33.935
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20080961122C_ACCS01
Start Time: 2008-096T11:22:46.312 Stop Time: 2008-097T00:54:34.232
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20080970058C_ACCS01
Start Time: 2008-097T00:58:46.733 Stop Time: 2008-097T04:36:13.611
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20080981051C_ACCS01
Start Time: 2008-098T10:51:39.130 Stop Time: 2008-098T11:32:48.627
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20080981735C_ACCS01
Start Time: 2008-098T17:35:12.633 Stop Time: 2008-098T18:23:52.085
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20080990025C_ACCS01
Start Time: 2008-099T00:25:40.625 Stop Time: 2008-099T01:14:19.984
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20080992104C_ACCS01
Start Time: 2008-099T21:04:13.629 Stop Time: 2008-099T21:46:59.862
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081001735C_ACCS01
Start Time: 2008-100T17:35:46.258 Stop Time: 2008-100T18:19:36.271
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081020341C_ACCS01
Start Time: 2008-102T03:41:13.628 Stop Time: 2008-102T04:33:06.106
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081030012C_ACCS01
Start Time: 2008-103T00:12:48.180 Stop Time: 2008-103T01:05:44.665
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081051347C_ACCS01
Start Time: 2008-105T13:47:22.250 Stop Time: 2008-105T14:42:59.670
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081072031C_ACCS01
Start Time: 2008-107T20:31:24.618 Stop Time: 2008-107T21:29:10.754
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081080706C_ACCS01
Start Time: 2008-108T07:06:28.621 Stop Time: 2008-108T12:46:40.164
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081082353C_ACCS01
Start Time: 2008-108T23:53:24.608 Stop Time: 2008-109T00:52:15.231
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081100704C_ACCS01
Start Time: 2008-110T07:04:39.116 Stop Time: 2008-110T12:40:00.374
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081101703C_ACCS01
Start Time: 2008-110T17:03:30.263 Stop Time: 2008-110T19:30:45.934
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081112018C_ACCS01
Start Time: 2008-111T20:18:26.238 Stop Time: 2008-111T21:19:57.348
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081132012C_ACCS01
Start Time: 2008-113T20:12:01.599 Stop Time: 2008-113T21:15:41.366
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081140801C_ACCS01
Start Time: 2008-114T08:01:03.097 Stop Time: 2008-114T12:27:16.556
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081150604C_ACCS01
Start Time: 2008-115T06:04:33.595 Stop Time: 2008-115T08:59:09.425
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081160759C_ACCS01
Start Time: 2008-116T07:59:17.584 Stop Time: 2008-116T10:57:05.043
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081171959C_ACCS01
Start Time: 2008-117T19:59:15.214 Stop Time: 2008-117T21:07:12.373
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081180249C_ACCS01
Start Time: 2008-118T02:49:44.603 Stop Time: 2008-118T03:57:42.098
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20081200250C_ACCS01
Start Time: 2008-120T02:50:16.586 Stop Time: 2008-120T03:53:24.430
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20080920304C_ACCS01
Start Time: 2008-092T03:04:50.162 Stop Time: 2008-092T11:31:35.535
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20080921135C_ACCS01
Start Time: 2008-092T11:35:15.504 Stop Time: 2008-092T15:08:26.129
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20080941800C_ACCS01
Start Time: 2008-094T18:00:47.922 Stop Time: 2008-094T19:40:54.235
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20080942306C_ACCS01
Start Time: 2008-094T23:06:07.043 Stop Time: 2008-095T04:36:46.759
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20080960409C_ACCS01
Start Time: 2008-096T04:09:49.300 Stop Time: 2008-096T11:18:36.029
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20080961122C_ACCS01
Start Time: 2008-096T11:22:15.937 Stop Time: 2008-097T00:54:36.326
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20080970058C_ACCS01
Start Time: 2008-097T00:58:16.358 Stop Time: 2008-097T04:36:15.705
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20080981051C_ACCS01
Start Time: 2008-098T10:51:41.005 Stop Time: 2008-098T11:32:50.721
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20080981735C_ACCS01
Start Time: 2008-098T17:35:14.508 Stop Time: 2008-098T18:23:54.179
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20080990025C_ACCS01
Start Time: 2008-099T00:25:42.500 Stop Time: 2008-099T01:14:22.078
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20080992104C_ACCS01
Start Time: 2008-099T21:04:15.504 Stop Time: 2008-099T21:47:01.956
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081001735C_ACCS01
Start Time: 2008-100T17:35:48.133 Stop Time: 2008-100T18:19:38.365
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081020341C_ACCS01
Start Time: 2008-102T03:41:15.503 Stop Time: 2008-102T04:33:08.200
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081030012C_ACCS01
Start Time: 2008-103T00:12:50.055 Stop Time: 2008-103T01:05:46.759
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081051347C_ACCS01
Start Time: 2008-105T13:47:24.125 Stop Time: 2008-105T14:43:01.763
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081072031C_ACCS01
Start Time: 2008-107T20:31:26.493 Stop Time: 2008-107T21:29:12.847
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081080706C_ACCS01
Start Time: 2008-108T07:06:30.496 Stop Time: 2008-108T12:46:42.258
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081082353C_ACCS01
Start Time: 2008-108T23:53:26.483 Stop Time: 2008-109T00:52:17.325
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081100704C_ACCS01
Start Time: 2008-110T07:04:40.991 Stop Time: 2008-110T12:40:02.468
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081101703C_ACCS01
Start Time: 2008-110T17:03:32.138 Stop Time: 2008-110T19:30:48.027
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081112018C_ACCS01
Start Time: 2008-111T20:18:28.113 Stop Time: 2008-111T21:19:59.442
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081132012C_ACCS01
Start Time: 2008-113T20:12:03.474 Stop Time: 2008-113T21:15:43.460
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081140801C_ACCS01
Start Time: 2008-114T08:01:04.972 Stop Time: 2008-114T12:27:18.650
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081150604C_ACCS01
Start Time: 2008-115T06:04:35.470 Stop Time: 2008-115T08:59:11.519
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081160759C_ACCS01
Start Time: 2008-116T07:59:19.459 Stop Time: 2008-116T10:57:07.136
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081171959C_ACCS01
Start Time: 2008-117T19:59:17.089 Stop Time: 2008-117T21:07:14.466
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081180249C_ACCS01
Start Time: 2008-118T02:49:46.478 Stop Time: 2008-118T03:57:44.192
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20081200250C_ACCS01
Start Time: 2008-120T02:50:18.461 Stop Time: 2008-120T03:53:26.523
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench