• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Cassini >> MIMI
CASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE View Errata Order Volume Toggle viewing into brief mode
CO-S-MIMI-4-LEMMS-CALIB-V1.0 PDS 3      CERTIFIED
Start Time: 2004-01-01 08:00:00 - Stop Time: 2017-09-16 10:00:00
This contains calibrated Saturn tour data collected by the LEMMS sensor of the MIMI instrument aboard the Cassini spacecraft for the Cassini mission.
This contains calibrated Saturn tour data collected by the LEMMS sensor of the MIMI instrument aboard the Cassini spacecraft for the Cassini mission.    less ...
Citiation Information
Author Vandegriff J., Kusterer M.B.
TitleCASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE
PublisherNASA Planetary Data System
Publication Year 2018
doi https://doi.org/10.17189/1519608
Top/ DATA/ LPHAFULL0/ 2014 / click here to download folders and files
LPHAFULL0_2014001_01
Start Time: 2014-001T00:00:01.148 Stop Time: 2014-001T23:59:48.537
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014002_01
Start Time: 2014-002T00:00:03.541 Stop Time: 2014-002T23:59:58.488
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014003_01
Start Time: 2014-003T00:00:24.738 Stop Time: 2014-003T23:59:58.939
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014004_01
Start Time: 2014-004T00:00:21.439 Stop Time: 2014-004T23:59:59.390
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014005_01
Start Time: 2014-005T00:00:21.890 Stop Time: 2014-005T23:59:58.841
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014006_01
Start Time: 2014-006T00:00:21.341 Stop Time: 2014-006T23:59:40.792
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014007_01
Start Time: 2014-007T00:00:03.292 Stop Time: 2014-007T23:59:55.118
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014008_01
Start Time: 2014-008T00:00:11.055 Stop Time: 2014-008T23:59:53.698
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014009_01
Start Time: 2014-009T00:00:09.529 Stop Time: 2014-009T23:59:54.070
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014010_01
Start Time: 2014-010T00:00:01.988 Stop Time: 2014-010T22:28:46.068
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014011_01
Start Time: 2014-011T12:03:40.323 Stop Time: 2014-011T23:59:58.796
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014012_01
Start Time: 2014-012T00:00:02.546 Stop Time: 2014-012T23:59:51.747
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014013_01
Start Time: 2014-013T00:00:04.872 Stop Time: 2014-013T23:59:56.948
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014014_01
Start Time: 2014-014T00:00:04.448 Stop Time: 2014-014T23:59:52.149
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014015_01
Start Time: 2014-015T00:00:05.274 Stop Time: 2014-015T23:59:55.475
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014016_01
Start Time: 2014-016T00:00:02.038 Stop Time: 2014-016T23:59:55.551
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014017_01
Start Time: 2014-017T00:00:08.676 Stop Time: 2014-017T23:59:59.877
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014018_01
Start Time: 2014-018T00:00:06.440 Stop Time: 2014-018T23:59:58.770
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014019_01
Start Time: 2014-019T00:00:07.207 Stop Time: 2014-019T23:59:57.404
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014020_01
Start Time: 2014-020T00:00:03.967 Stop Time: 2014-020T23:59:40.105
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014021_01
Start Time: 2014-021T00:00:02.605 Stop Time: 2014-021T23:59:39.555
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014022_01
Start Time: 2014-022T00:00:02.055 Stop Time: 2014-022T23:59:40.006
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014023_01
Start Time: 2014-023T00:00:02.506 Stop Time: 2014-023T23:59:40.457
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014024_01
Start Time: 2014-024T00:00:02.957 Stop Time: 2014-024T23:59:39.908
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014025_01
Start Time: 2014-025T00:00:02.408 Stop Time: 2014-025T23:59:40.359
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014026_01
Start Time: 2014-026T00:00:02.859 Stop Time: 2014-026T23:59:40.810
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014027_01
Start Time: 2014-027T00:00:03.310 Stop Time: 2014-027T23:59:55.761
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014028_01
Start Time: 2014-028T00:00:18.264 Stop Time: 2014-028T23:59:41.212
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014029_01
Start Time: 2014-029T00:00:03.715 Stop Time: 2014-029T23:59:48.663
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014030_01
Start Time: 2014-030T00:00:11.166 Stop Time: 2014-030T23:59:45.617
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014031_01
Start Time: 2014-031T00:00:08.113 Stop Time: 2014-031T23:59:40.565
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014032_01
Start Time: 2014-032T00:00:03.068 Stop Time: 2014-032T23:59:46.015
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014033_01
Start Time: 2014-033T00:00:08.519 Stop Time: 2014-033T23:59:38.970
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014034_01
Start Time: 2014-034T00:00:01.466 Stop Time: 2014-034T23:59:54.417
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014035_01
Start Time: 2014-035T00:00:16.917 Stop Time: 2014-035T23:59:53.993
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014036_01
Start Time: 2014-036T00:00:00.556 Stop Time: 2014-036T23:59:42.323
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014037_01
Start Time: 2014-037T00:00:04.819 Stop Time: 2014-037T23:59:57.770
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014038_01
Start Time: 2014-038T00:00:05.270 Stop Time: 2014-038T23:59:51.721
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014039_01
Start Time: 2014-039T00:00:14.225 Stop Time: 2014-039T23:59:52.172
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014040_01
Start Time: 2014-040T00:00:14.676 Stop Time: 2014-040T23:59:59.123
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014041_01
Start Time: 2014-041T00:00:06.623 Stop Time: 2014-041T23:59:53.074
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014042_01
Start Time: 2014-042T00:00:00.574 Stop Time: 2014-042T23:59:54.525
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014043_01
Start Time: 2014-043T00:00:02.025 Stop Time: 2014-043T23:59:38.976
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014044_01
Start Time: 2014-044T00:00:01.476 Stop Time: 2014-044T23:59:54.427
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014045_01
Start Time: 2014-045T00:00:01.927 Stop Time: 2014-045T23:59:39.878
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014046_01
Start Time: 2014-046T00:00:02.378 Stop Time: 2014-046T23:59:39.829
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014047_01
Start Time: 2014-047T00:00:02.329 Stop Time: 2014-047T23:59:47.780
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014048_01
Start Time: 2014-048T00:00:10.279 Stop Time: 2014-048T23:59:54.231
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014049_01
Start Time: 2014-049T00:00:16.734 Stop Time: 2014-049T23:59:55.185
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014050_01
Start Time: 2014-050T00:00:17.681 Stop Time: 2014-050T23:59:54.636
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014051_01
Start Time: 2014-051T00:00:17.132 Stop Time: 2014-051T23:59:58.583
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014052_01
Start Time: 2014-052T00:00:21.087 Stop Time: 2014-052T23:59:58.034
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014053_01
Start Time: 2014-053T00:00:20.538 Stop Time: 2014-053T23:59:41.485
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014054_01
Start Time: 2014-054T00:00:03.985 Stop Time: 2014-054T23:59:41.936
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014055_01
Start Time: 2014-055T00:00:04.436 Stop Time: 2014-055T23:59:46.891
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014056_01
Start Time: 2014-056T00:00:09.387 Stop Time: 2014-056T23:59:47.342
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014057_01
Start Time: 2014-057T00:00:09.838 Stop Time: 2014-057T23:59:46.793
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014058_01
Start Time: 2014-058T00:00:09.289 Stop Time: 2014-058T23:59:47.244
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014059_01
Start Time: 2014-059T00:00:09.740 Stop Time: 2014-059T23:59:47.695
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014060_01
Start Time: 2014-060T00:00:10.191 Stop Time: 2014-060T23:59:47.146
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014061_01
Start Time: 2014-061T00:00:09.642 Stop Time: 2014-061T23:59:38.593
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014062_01
Start Time: 2014-062T00:00:01.093 Stop Time: 2014-062T23:59:41.044
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014063_01
Start Time: 2014-063T00:00:03.544 Stop Time: 2014-063T23:59:48.499
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014064_01
Start Time: 2014-064T00:00:10.995 Stop Time: 2014-064T23:59:58.321
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014065_01
Start Time: 2014-065T00:00:04.883 Stop Time: 2014-065T23:59:42.897
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014066_01
Start Time: 2014-066T00:00:05.400 Stop Time: 2014-066T23:59:58.347
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014067_01
Start Time: 2014-067T00:00:20.847 Stop Time: 2014-067T23:59:58.798
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014068_01
Start Time: 2014-068T00:00:06.302 Stop Time: 2014-068T23:59:54.248
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014069_01
Start Time: 2014-069T00:00:16.748 Stop Time: 2014-069T23:59:58.949
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014070_01
Start Time: 2014-070T00:00:12.074 Stop Time: 2014-070T23:59:54.525
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014071_01
Start Time: 2014-071T00:00:07.654 Stop Time: 2014-071T23:59:57.851
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014072_01
Start Time: 2014-072T00:00:10.976 Stop Time: 2014-072T23:59:57.427
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014073_01
Start Time: 2014-073T00:00:29.302 Stop Time: 2014-073T23:59:38.628
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014074_01
Start Time: 2014-074T00:00:11.007 Stop Time: 2014-074T23:59:29.204
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014075_01
Start Time: 2014-075T00:00:01.079 Stop Time: 2014-075T23:59:42.780
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014076_01
Start Time: 2014-076T00:00:14.655 Stop Time: 2014-076T23:59:56.360
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014077_01
Start Time: 2014-077T00:00:28.231 Stop Time: 2014-077T23:59:37.557
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014078_01
Start Time: 2014-078T00:00:09.432 Stop Time: 2014-078T23:59:51.133
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014079_01
Start Time: 2014-079T00:00:23.007 Stop Time: 2014-079T23:59:32.334
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014080_01
Start Time: 2014-080T00:00:04.712 Stop Time: 2014-080T23:59:45.910
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014081_01
Start Time: 2014-081T00:00:17.784 Stop Time: 2014-081T23:59:59.485
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014082_01
Start Time: 2014-082T00:00:31.360 Stop Time: 2014-082T23:59:50.936
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014083_01
Start Time: 2014-083T00:00:22.811 Stop Time: 2014-083T23:59:33.137
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014084_01
Start Time: 2014-084T00:00:04.516 Stop Time: 2014-084T23:59:33.588
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014085_01
Start Time: 2014-085T00:00:04.967 Stop Time: 2014-085T23:59:47.164
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014086_01
Start Time: 2014-086T00:00:19.039 Stop Time: 2014-086T23:59:48.615
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014087_01
Start Time: 2014-087T00:00:20.490 Stop Time: 2014-087T23:59:30.320
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014088_01
Start Time: 2014-088T00:00:02.191 Stop Time: 2014-088T23:59:34.771
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014089_01
Start Time: 2014-089T00:00:06.642 Stop Time: 2014-089T23:59:42.913
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014090_01
Start Time: 2014-090T00:00:15.261 Stop Time: 2014-090T23:59:34.419
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014091_01
Start Time: 2014-091T00:00:06.294 Stop Time: 2014-091T23:59:54.870
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014092_01
Start Time: 2014-092T00:00:26.744 Stop Time: 2014-092T23:59:46.321
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014093_01
Start Time: 2014-093T00:00:18.195 Stop Time: 2014-093T23:59:58.771
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014094_01
Start Time: 2014-094T00:00:30.646 Stop Time: 2014-094T23:59:38.098
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014095_01
Start Time: 2014-095T00:00:09.476 Stop Time: 2014-095T23:59:52.927
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014096_01
Start Time: 2014-096T00:00:24.798 Stop Time: 2014-096T23:59:53.374
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014097_01
Start Time: 2014-097T00:00:15.874 Stop Time: 2014-097T23:59:53.825
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014098_01
Start Time: 2014-098T00:00:01.325 Stop Time: 2014-098T23:59:55.276
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014099_01
Start Time: 2014-099T00:00:17.776 Stop Time: 2014-099T23:59:55.727
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014100_01
Start Time: 2014-100T00:00:03.227 Stop Time: 2014-100T23:59:58.678
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014101_01
Start Time: 2014-101T00:00:06.178 Stop Time: 2014-101T23:59:39.129
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014102_01
Start Time: 2014-102T00:00:01.629 Stop Time: 2014-102T23:59:54.580
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014103_01
Start Time: 2014-103T00:00:02.080 Stop Time: 2014-103T23:59:56.031
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014104_01
Start Time: 2014-104T00:00:03.531 Stop Time: 2014-104T23:59:46.986
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014105_01
Start Time: 2014-105T00:00:09.482 Stop Time: 2014-105T23:59:47.436
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014106_01
Start Time: 2014-106T00:00:09.932 Stop Time: 2014-106T23:59:59.887
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014107_01
Start Time: 2014-107T00:00:22.383 Stop Time: 2014-107T23:59:37.834
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014108_01
Start Time: 2014-108T00:00:00.338 Stop Time: 2014-108T12:37:16.546
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014109_01
Start Time: 2014-109T01:01:41.766 Stop Time: 2014-109T23:59:47.736
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014110_01
Start Time: 2014-110T00:00:10.240 Stop Time: 2014-110T23:59:38.687
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014111_01
Start Time: 2014-111T00:00:01.187 Stop Time: 2014-111T23:59:38.638
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014112_01
Start Time: 2014-112T00:00:01.138 Stop Time: 2014-112T23:59:57.593
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014113_01
Start Time: 2014-113T00:00:20.089 Stop Time: 2014-113T23:59:49.040
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014114_01
Start Time: 2014-114T00:00:11.540 Stop Time: 2014-114T23:59:55.991
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014115_01
Start Time: 2014-115T00:00:18.494 Stop Time: 2014-115T23:59:39.946
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014116_01
Start Time: 2014-116T00:00:02.442 Stop Time: 2014-116T23:59:39.397
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014117_01
Start Time: 2014-117T00:00:01.893 Stop Time: 2014-117T23:59:46.344
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014118_01
Start Time: 2014-118T00:00:08.847 Stop Time: 2014-118T23:59:45.794
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014119_01
Start Time: 2014-119T00:00:08.298 Stop Time: 2014-119T23:59:43.746
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014120_01
Start Time: 2014-120T00:00:06.246 Stop Time: 2014-120T23:59:44.197
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014121_01
Start Time: 2014-121T00:00:06.697 Stop Time: 2014-121T23:59:48.648
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014122_01
Start Time: 2014-122T00:00:11.148 Stop Time: 2014-122T23:59:48.099
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014123_01
Start Time: 2014-123T00:00:10.599 Stop Time: 2014-123T23:59:48.550
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014124_01
Start Time: 2014-124T00:00:11.050 Stop Time: 2014-124T23:59:49.001
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014125_01
Start Time: 2014-125T00:00:11.501 Stop Time: 2014-125T23:59:48.452
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014126_01
Start Time: 2014-126T00:00:10.952 Stop Time: 2014-126T23:59:48.903
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014127_01
Start Time: 2014-127T00:00:11.403 Stop Time: 2014-127T11:18:10.144
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014129_01
Start Time: 2014-129T10:54:34.559 Stop Time: 2014-129T23:59:49.255
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014130_01
Start Time: 2014-130T00:00:11.755 Stop Time: 2014-130T23:59:48.706
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014131_01
Start Time: 2014-131T00:00:11.206 Stop Time: 2014-131T23:59:49.157
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014132_01
Start Time: 2014-132T00:00:11.657 Stop Time: 2014-132T23:59:49.608
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014133_01
Start Time: 2014-133T00:00:12.108 Stop Time: 2014-133T23:59:56.559
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014134_01
Start Time: 2014-134T00:00:19.059 Stop Time: 2014-134T23:59:57.010
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014135_01
Start Time: 2014-135T00:00:19.510 Stop Time: 2014-135T23:59:57.461
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014136_01
Start Time: 2014-136T00:00:19.961 Stop Time: 2014-136T23:59:42.912
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014137_01
Start Time: 2014-137T00:00:05.416 Stop Time: 2014-137T23:59:58.363
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014138_01
Start Time: 2014-138T00:00:20.862 Stop Time: 2014-138T23:59:57.813
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014139_01
Start Time: 2014-139T00:00:20.313 Stop Time: 2014-139T23:59:57.764
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014140_01
Start Time: 2014-140T00:00:20.264 Stop Time: 2014-140T23:59:59.215
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014141_01
Start Time: 2014-141T00:00:06.715 Stop Time: 2014-141T23:59:53.166
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014142_01
Start Time: 2014-142T00:00:15.670 Stop Time: 2014-142T23:59:52.121
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014143_01
Start Time: 2014-143T00:00:14.617 Stop Time: 2014-143T23:59:52.572
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014144_01
Start Time: 2014-144T00:00:15.068 Stop Time: 2014-144T23:59:52.023
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014145_01
Start Time: 2014-145T00:00:14.519 Stop Time: 2014-145T23:59:52.474
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014146_01
Start Time: 2014-146T00:00:14.970 Stop Time: 2014-146T23:59:52.925
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014147_01
Start Time: 2014-147T00:00:15.421 Stop Time: 2014-147T23:59:52.376
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014148_01
Start Time: 2014-148T00:00:14.871 Stop Time: 2014-148T23:59:52.826
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014149_01
Start Time: 2014-149T00:00:15.322 Stop Time: 2014-149T23:59:53.277
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014150_01
Start Time: 2014-150T00:00:15.773 Stop Time: 2014-150T23:59:52.728
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014151_01
Start Time: 2014-151T00:00:15.224 Stop Time: 2014-151T23:59:53.179
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014152_01
Start Time: 2014-152T00:00:15.675 Stop Time: 2014-152T23:59:53.630
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014153_01
Start Time: 2014-153T00:00:16.126 Stop Time: 2014-153T23:59:53.081
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014154_01
Start Time: 2014-154T00:00:15.577 Stop Time: 2014-154T23:59:53.532
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014155_01
Start Time: 2014-155T00:00:16.028 Stop Time: 2014-155T23:59:44.983
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014156_01
Start Time: 2014-156T00:00:07.479 Stop Time: 2014-156T23:59:45.434
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014157_01
Start Time: 2014-157T00:00:07.930 Stop Time: 2014-157T23:59:56.881
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014158_01
Start Time: 2014-158T00:00:19.380 Stop Time: 2014-158T23:59:56.331
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014159_01
Start Time: 2014-159T00:00:18.831 Stop Time: 2014-159T23:59:47.786
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014160_01
Start Time: 2014-160T00:00:10.282 Stop Time: 2014-160T23:59:48.237
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014161_01
Start Time: 2014-161T00:00:10.733 Stop Time: 2014-161T23:59:38.184
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014162_01
Start Time: 2014-162T00:00:00.684 Stop Time: 2014-162T23:59:38.635
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014163_01
Start Time: 2014-163T00:00:01.135 Stop Time: 2014-163T23:59:46.086
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014164_01
Start Time: 2014-164T00:00:08.590 Stop Time: 2014-164T23:59:49.041
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014165_01
Start Time: 2014-165T00:00:11.537 Stop Time: 2014-165T23:59:47.488
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014166_01
Start Time: 2014-166T00:00:09.988 Stop Time: 2014-166T23:59:46.939
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014167_01
Start Time: 2014-167T00:00:09.439 Stop Time: 2014-167T23:59:54.890
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014168_01
Start Time: 2014-168T00:00:02.393 Stop Time: 2014-168T23:59:47.842
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014169_01
Start Time: 2014-169T00:00:10.341 Stop Time: 2014-169T23:59:48.243
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014170_01
Start Time: 2014-170T00:00:10.743 Stop Time: 2014-170T23:59:56.193
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014171_01
Start Time: 2014-171T00:00:03.693 Stop Time: 2014-171T23:59:49.144
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014172_01
Start Time: 2014-172T00:00:11.644 Stop Time: 2014-172T23:59:42.094
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014173_01
Start Time: 2014-173T00:00:04.598 Stop Time: 2014-173T23:59:42.545
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014174_01
Start Time: 2014-174T00:00:05.048 Stop Time: 2014-174T23:59:41.995
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014175_01
Start Time: 2014-175T00:00:04.499 Stop Time: 2014-175T23:59:42.445
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014176_01
Start Time: 2014-176T00:00:04.949 Stop Time: 2014-176T23:59:41.896
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014177_01
Start Time: 2014-177T00:00:04.399 Stop Time: 2014-177T23:59:42.346
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014178_01
Start Time: 2014-178T00:00:04.850 Stop Time: 2014-178T23:59:42.796
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014179_01
Start Time: 2014-179T00:00:05.300 Stop Time: 2014-179T23:59:50.751
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014180_01
Start Time: 2014-180T00:00:06.790 Stop Time: 2014-180T23:59:55.697
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014181_01
Start Time: 2014-181T00:00:18.201 Stop Time: 2014-181T23:59:51.230
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014182_01
Start Time: 2014-182T00:00:07.089 Stop Time: 2014-182T23:59:44.395
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014183_01
Start Time: 2014-183T00:00:00.539 Stop Time: 2014-183T23:59:57.822
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014184_01
Start Time: 2014-184T00:00:13.888 Stop Time: 2014-184T23:59:48.378
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014185_01
Start Time: 2014-185T00:00:04.471 Stop Time: 2014-185T23:59:55.406
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014186_01
Start Time: 2014-186T00:00:11.398 Stop Time: 2014-186T23:59:56.102
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014187_01
Start Time: 2014-187T00:00:12.173 Stop Time: 2014-187T23:59:43.350
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014188_01
Start Time: 2014-188T00:00:05.850 Stop Time: 2014-188T23:59:50.300
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014189_01
Start Time: 2014-189T00:00:12.800 Stop Time: 2014-189T23:59:49.751
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014190_01
Start Time: 2014-190T00:00:12.250 Stop Time: 2014-190T23:59:50.201
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014191_01
Start Time: 2014-191T00:00:12.701 Stop Time: 2014-191T23:59:49.651
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014192_01
Start Time: 2014-192T00:00:12.151 Stop Time: 2014-192T23:59:50.102
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014193_01
Start Time: 2014-193T00:00:12.602 Stop Time: 2014-193T23:59:50.552
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014194_01
Start Time: 2014-194T00:00:13.052 Stop Time: 2014-194T23:59:53.002
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014195_01
Start Time: 2014-195T00:00:15.506 Stop Time: 2014-195T23:59:58.453
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014196_01
Start Time: 2014-196T00:00:20.957 Stop Time: 2014-196T23:59:58.903
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014197_01
Start Time: 2014-197T00:00:21.407 Stop Time: 2014-197T23:59:58.353
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014198_01
Start Time: 2014-198T00:00:20.853 Stop Time: 2014-198T23:59:56.804
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014199_01
Start Time: 2014-199T00:00:04.308 Stop Time: 2014-199T23:59:57.754
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014200_01
Start Time: 2014-200T00:00:05.254 Stop Time: 2014-200T23:59:57.205
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014201_01
Start Time: 2014-201T00:00:19.704 Stop Time: 2014-201T23:59:57.655
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014202_01
Start Time: 2014-202T00:00:20.155 Stop Time: 2014-202T23:59:58.105
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014203_01
Start Time: 2014-203T00:00:20.605 Stop Time: 2014-203T23:59:55.560
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014204_01
Start Time: 2014-204T00:00:11.571 Stop Time: 2014-204T23:59:52.011
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014205_01
Start Time: 2014-205T00:00:14.507 Stop Time: 2014-205T23:59:50.958
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014206_01
Start Time: 2014-206T00:00:13.457 Stop Time: 2014-206T23:59:51.408
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014207_01
Start Time: 2014-207T00:00:13.908 Stop Time: 2014-207T23:59:51.858
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014208_01
Start Time: 2014-208T00:00:14.358 Stop Time: 2014-208T23:59:51.309
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014209_01
Start Time: 2014-209T00:00:13.809 Stop Time: 2014-209T23:59:56.466
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014210_01
Start Time: 2014-210T00:00:12.509 Stop Time: 2014-210T23:59:53.713
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014211_01
Start Time: 2014-211T00:00:16.209 Stop Time: 2014-211T23:59:54.164
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014212_01
Start Time: 2014-212T00:00:16.660 Stop Time: 2014-212T23:59:54.614
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014213_01
Start Time: 2014-213T00:00:17.110 Stop Time: 2014-213T23:59:54.064
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014214_01
Start Time: 2014-214T00:00:16.560 Stop Time: 2014-214T23:59:54.515
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014215_01
Start Time: 2014-215T00:00:17.011 Stop Time: 2014-215T23:59:54.965
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014216_01
Start Time: 2014-216T00:00:17.461 Stop Time: 2014-216T23:59:54.416
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014217_01
Start Time: 2014-217T00:00:16.912 Stop Time: 2014-217T23:59:54.866
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014218_01
Start Time: 2014-218T00:00:17.362 Stop Time: 2014-218T23:59:55.316
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014219_01
Start Time: 2014-219T00:00:17.812 Stop Time: 2014-219T23:59:54.767
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014220_01
Start Time: 2014-220T00:00:17.263 Stop Time: 2014-220T23:59:55.217
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014221_01
Start Time: 2014-221T00:00:17.713 Stop Time: 2014-221T23:59:45.164
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014222_01
Start Time: 2014-222T00:00:07.664 Stop Time: 2014-222T23:59:44.614
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014223_01
Start Time: 2014-223T00:00:07.114 Stop Time: 2014-223T23:59:45.064
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014224_01
Start Time: 2014-224T00:00:07.564 Stop Time: 2014-224T23:59:46.265
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014225_01
Start Time: 2014-225T00:00:02.308 Stop Time: 2014-225T23:59:45.965
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014226_01
Start Time: 2014-226T00:00:08.469 Stop Time: 2014-226T23:59:46.416
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014227_01
Start Time: 2014-227T00:00:08.919 Stop Time: 2014-227T23:59:46.866
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014228_01
Start Time: 2014-228T00:00:09.370 Stop Time: 2014-228T23:59:55.816
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014229_01
Start Time: 2014-229T00:00:18.316 Stop Time: 2014-229T23:59:49.767
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014230_01
Start Time: 2014-230T00:00:12.267 Stop Time: 2014-230T23:59:50.217
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014231_01
Start Time: 2014-231T00:00:12.717 Stop Time: 2014-231T23:59:43.167
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014232_01
Start Time: 2014-232T00:00:05.667 Stop Time: 2014-232T23:59:35.622
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014233_01
Start Time: 2014-233T00:00:07.493 Stop Time: 2014-233T23:59:43.068
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014234_01
Start Time: 2014-234T00:00:05.568 Stop Time: 2014-234T23:59:38.394
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014235_01
Start Time: 2014-235T00:00:10.268 Stop Time: 2014-235T23:59:44.594
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014236_01
Start Time: 2014-236T00:00:15.973 Stop Time: 2014-236T23:59:54.294
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014237_01
Start Time: 2014-237T00:00:26.169 Stop Time: 2014-237T23:59:31.620
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014238_01
Start Time: 2014-238T00:00:03.495 Stop Time: 2014-238T23:59:44.324
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014239_01
Start Time: 2014-239T00:00:16.195 Stop Time: 2014-239T23:59:58.395
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014240_01
Start Time: 2014-240T00:00:29.774 Stop Time: 2014-240T23:59:39.096
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014241_01
Start Time: 2014-241T00:00:10.971 Stop Time: 2014-241T23:59:55.296
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014242_01
Start Time: 2014-242T00:00:27.675 Stop Time: 2014-242T23:59:36.997
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014243_01
Start Time: 2014-243T00:00:08.872 Stop Time: 2014-243T23:59:51.197
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014244_01
Start Time: 2014-244T00:00:23.576 Stop Time: 2014-244T23:59:50.897
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014245_01
Start Time: 2014-245T00:00:22.772 Stop Time: 2014-245T23:59:41.223
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014246_01
Start Time: 2014-246T00:00:13.098 Stop Time: 2014-246T23:59:54.798
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014247_01
Start Time: 2014-247T00:00:26.673 Stop Time: 2014-247T23:59:47.249
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014248_01
Start Time: 2014-248T00:00:19.123 Stop Time: 2014-248T23:59:45.574
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014249_01
Start Time: 2014-249T00:00:17.449 Stop Time: 2014-249T23:59:59.899
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014250_01
Start Time: 2014-250T00:00:32.278 Stop Time: 2014-250T23:59:43.729
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014251_01
Start Time: 2014-251T00:00:15.600 Stop Time: 2014-251T23:59:56.179
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014252_01
Start Time: 2014-252T00:00:28.050 Stop Time: 2014-252T23:59:44.631
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014253_01
Start Time: 2014-253T00:00:16.923 Stop Time: 2014-253T23:59:47.827
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014254_01
Start Time: 2014-254T00:00:19.702 Stop Time: 2014-254T23:00:12.753
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014255_01
Start Time: 2014-255T10:55:24.281 Stop Time: 2014-255T23:59:30.982
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014256_01
Start Time: 2014-256T00:00:02.853 Stop Time: 2014-256T23:59:34.202
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014257_01
Start Time: 2014-257T00:00:05.971 Stop Time: 2014-257T23:59:34.504
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014258_01
Start Time: 2014-258T00:00:06.882 Stop Time: 2014-258T23:59:33.337
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014259_01
Start Time: 2014-259T00:00:04.333 Stop Time: 2014-259T23:59:31.654
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014260_01
Start Time: 2014-260T00:00:03.529 Stop Time: 2014-260T23:59:46.980
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014261_01
Start Time: 2014-261T00:00:18.855 Stop Time: 2014-261T23:59:53.684
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014262_01
Start Time: 2014-262T00:00:16.180 Stop Time: 2014-262T23:59:45.631
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014263_01
Start Time: 2014-263T00:00:08.130 Stop Time: 2014-263T23:59:44.081
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014264_01
Start Time: 2014-264T00:00:06.581 Stop Time: 2014-264T23:59:43.531
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014265_01
Start Time: 2014-265T00:00:06.031 Stop Time: 2014-265T23:59:49.220
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014266_01
Start Time: 2014-266T00:00:05.364 Stop Time: 2014-266T23:59:57.432
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014267_01
Start Time: 2014-267T00:00:19.936 Stop Time: 2014-267T23:59:31.387
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014268_01
Start Time: 2014-268T00:00:03.625 Stop Time: 2014-268T23:59:33.606
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014269_01
Start Time: 2014-269T00:00:05.376 Stop Time: 2014-269T23:59:29.725
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014270_01
Start Time: 2014-270T00:00:01.447 Stop Time: 2014-270T23:59:39.738
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014271_01
Start Time: 2014-271T00:00:02.234 Stop Time: 2014-271T23:59:53.567
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014272_01
Start Time: 2014-272T00:00:09.188 Stop Time: 2014-272T23:59:40.135
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014273_01
Start Time: 2014-273T00:00:02.638 Stop Time: 2014-273T23:59:40.585
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014274_01
Start Time: 2014-274T00:00:03.089 Stop Time: 2014-274T23:59:35.672
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014275_01
Start Time: 2014-275T00:00:07.809 Stop Time: 2014-275T23:59:55.486
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014276_01
Start Time: 2014-276T00:00:17.989 Stop Time: 2014-276T23:59:45.737
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014277_01
Start Time: 2014-277T00:00:01.600 Stop Time: 2014-277T23:59:56.386
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014278_01
Start Time: 2014-278T00:00:18.890 Stop Time: 2014-278T23:59:56.837
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014279_01
Start Time: 2014-279T00:00:19.341 Stop Time: 2014-279T23:59:56.287
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014280_01
Start Time: 2014-280T00:00:18.791 Stop Time: 2014-280T23:59:56.738
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014281_01
Start Time: 2014-281T00:00:19.241 Stop Time: 2014-281T23:59:57.188
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014282_01
Start Time: 2014-282T00:00:19.692 Stop Time: 2014-282T23:59:56.639
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014283_01
Start Time: 2014-283T00:00:19.142 Stop Time: 2014-283T23:59:57.089
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014284_01
Start Time: 2014-284T00:00:19.593 Stop Time: 2014-284T23:59:57.539
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014285_01
Start Time: 2014-285T00:00:20.043 Stop Time: 2014-285T23:59:56.990
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014286_01
Start Time: 2014-286T00:00:19.494 Stop Time: 2014-286T23:59:54.440
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014287_01
Start Time: 2014-287T00:00:16.944 Stop Time: 2014-287T19:47:52.987
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014288_01
Start Time: 2014-288T11:24:17.133 Stop Time: 2014-288T23:59:45.341
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014289_01
Start Time: 2014-289T00:00:07.841 Stop Time: 2014-289T23:59:45.791
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014290_01
Start Time: 2014-290T00:00:08.291 Stop Time: 2014-290T23:59:38.242
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014291_01
Start Time: 2014-291T00:00:04.492 Stop Time: 2014-291T23:59:50.130
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014292_01
Start Time: 2014-292T00:00:06.067 Stop Time: 2014-292T23:59:53.647
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014293_01
Start Time: 2014-293T00:00:09.580 Stop Time: 2014-293T23:59:47.031
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014294_01
Start Time: 2014-294T00:00:03.019 Stop Time: 2014-294T23:59:46.231
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014295_01
Start Time: 2014-295T00:00:02.168 Stop Time: 2014-295T06:38:04.891
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014296_01
Start Time: 2014-296T01:31:58.963 Stop Time: 2014-296T23:59:43.444
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014297_01
Start Time: 2014-297T00:00:05.944 Stop Time: 2014-297T23:59:46.180
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014298_01
Start Time: 2014-298T00:00:02.274 Stop Time: 2014-298T23:59:55.908
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014299_01
Start Time: 2014-299T00:00:11.349 Stop Time: 2014-299T23:59:55.171
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014300_01
Start Time: 2014-300T00:00:08.295 Stop Time: 2014-300T23:59:34.996
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014301_01
Start Time: 2014-301T00:00:06.871 Stop Time: 2014-301T23:59:36.446
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014302_01
Start Time: 2014-302T00:00:08.321 Stop Time: 2014-302T00:25:38.312
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014303_01
Start Time: 2014-303T08:10:10.964 Stop Time: 2014-303T23:59:31.221
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014304_01
Start Time: 2014-304T00:00:03.600 Stop Time: 2014-304T23:59:44.797
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014305_01
Start Time: 2014-305T00:00:16.671 Stop Time: 2014-305T23:59:57.372
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014306_01
Start Time: 2014-306T00:00:29.247 Stop Time: 2014-306T06:25:38.975
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014307_01
Start Time: 2014-307T11:20:11.692 Stop Time: 2014-307T23:59:52.148
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014308_01
Start Time: 2014-308T00:00:24.023 Stop Time: 2014-308T23:59:47.598
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014309_01
Start Time: 2014-309T00:00:19.473 Stop Time: 2014-309T23:59:29.303
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014310_01
Start Time: 2014-310T00:00:01.174 Stop Time: 2014-310T23:59:48.499
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014311_01
Start Time: 2014-311T00:00:20.374 Stop Time: 2014-311T23:59:29.204
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014312_01
Start Time: 2014-312T00:00:01.074 Stop Time: 2014-312T23:59:40.654
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014313_01
Start Time: 2014-313T00:00:12.525 Stop Time: 2014-313T23:59:53.725
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014314_01
Start Time: 2014-314T00:00:26.104 Stop Time: 2014-314T23:59:43.555
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014315_01
Start Time: 2014-315T00:00:15.273 Stop Time: 2014-315T23:59:59.751
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014316_01
Start Time: 2014-316T00:00:31.626 Stop Time: 2014-316T23:59:45.924
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014317_01
Start Time: 2014-317T00:00:02.018 Stop Time: 2014-317T23:59:40.902
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014318_01
Start Time: 2014-318T00:00:03.402 Stop Time: 2014-318T23:59:41.353
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014319_01
Start Time: 2014-319T00:00:03.852 Stop Time: 2014-319T23:59:40.803
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014320_01
Start Time: 2014-320T00:00:03.303 Stop Time: 2014-320T23:59:41.253
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014321_01
Start Time: 2014-321T00:00:03.753 Stop Time: 2014-321T23:59:39.704
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014322_01
Start Time: 2014-322T00:00:02.204 Stop Time: 2014-322T23:59:41.154
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014323_01
Start Time: 2014-323T00:00:03.654 Stop Time: 2014-323T23:59:40.605
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014324_01
Start Time: 2014-324T00:00:03.105 Stop Time: 2014-324T23:59:41.055
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014325_01
Start Time: 2014-325T00:00:03.555 Stop Time: 2014-325T23:59:54.509
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014326_01
Start Time: 2014-326T00:00:17.005 Stop Time: 2014-326T23:59:49.456
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014327_01
Start Time: 2014-327T00:00:11.956 Stop Time: 2014-327T23:59:53.410
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014328_01
Start Time: 2014-328T00:00:09.269 Stop Time: 2014-328T23:59:45.357
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014329_01
Start Time: 2014-329T00:00:07.861 Stop Time: 2014-329T23:59:46.807
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014330_01
Start Time: 2014-330T00:00:09.311 Stop Time: 2014-330T23:59:42.758
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014331_01
Start Time: 2014-331T00:00:05.257 Stop Time: 2014-331T23:59:43.208
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014332_01
Start Time: 2014-332T00:00:05.708 Stop Time: 2014-332T23:59:37.662
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014333_01
Start Time: 2014-333T00:00:00.158 Stop Time: 2014-333T23:59:37.609
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014334_01
Start Time: 2014-334T00:00:00.113 Stop Time: 2014-334T23:59:54.563
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014335_01
Start Time: 2014-335T00:00:17.059 Stop Time: 2014-335T23:59:45.947
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014336_01
Start Time: 2014-336T00:00:01.935 Stop Time: 2014-336T23:59:55.464
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014337_01
Start Time: 2014-337T00:00:17.960 Stop Time: 2014-337T23:59:51.911
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014338_01
Start Time: 2014-338T00:00:14.410 Stop Time: 2014-338T23:59:36.861
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014339_01
Start Time: 2014-339T00:23:59.356 Stop Time: 2014-339T23:59:51.311
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014340_01
Start Time: 2014-340T00:00:13.811 Stop Time: 2014-340T23:59:41.266
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014341_01
Start Time: 2014-341T00:00:03.762 Stop Time: 2014-341T23:59:58.212
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014342_01
Start Time: 2014-342T00:00:20.716 Stop Time: 2014-342T23:59:59.167
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014343_01
Start Time: 2014-343T00:00:21.663 Stop Time: 2014-343T23:59:44.613
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014344_01
Start Time: 2014-344T00:00:07.113 Stop Time: 2014-344T23:59:52.564
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014345_01
Start Time: 2014-345T00:00:01.939 Stop Time: 2014-345T23:59:45.518
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014346_01
Start Time: 2014-346T00:00:08.014 Stop Time: 2014-346T23:59:44.968
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014347_01
Start Time: 2014-347T00:00:07.464 Stop Time: 2014-347T23:59:45.419
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014348_01
Start Time: 2014-348T00:00:07.915 Stop Time: 2014-348T23:59:58.268
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014349_01
Start Time: 2014-349T00:00:13.998 Stop Time: 2014-349T23:59:57.316
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014350_01
Start Time: 2014-350T00:00:19.816 Stop Time: 2014-350T23:59:57.766
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014351_01
Start Time: 2014-351T00:00:20.265 Stop Time: 2014-351T23:59:57.181
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014352_01
Start Time: 2014-352T00:00:19.681 Stop Time: 2014-352T23:59:57.630
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014353_01
Start Time: 2014-353T00:00:20.130 Stop Time: 2014-353T23:59:58.080
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014354_01
Start Time: 2014-354T00:00:20.580 Stop Time: 2014-354T23:59:57.529
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014355_01
Start Time: 2014-355T00:00:20.029 Stop Time: 2014-355T23:59:57.979
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014356_01
Start Time: 2014-356T00:00:20.479 Stop Time: 2014-356T23:59:58.428
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014357_01
Start Time: 2014-357T00:00:20.928 Stop Time: 2014-357T23:59:57.878
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014358_01
Start Time: 2014-358T00:00:20.378 Stop Time: 2014-358T23:59:58.327
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014359_01
Start Time: 2014-359T00:00:20.827 Stop Time: 2014-359T23:59:47.632
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014360_01
Start Time: 2014-360T00:00:18.781 Stop Time: 2014-360T23:59:28.008
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014361_01
Start Time: 2014-361T00:00:00.230 Stop Time: 2014-361T23:59:52.301
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014362_01
Start Time: 2014-362T00:00:24.679 Stop Time: 2014-362T23:59:42.129
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014363_01
Start Time: 2014-363T00:00:13.797 Stop Time: 2014-363T23:59:41.075
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014364_01
Start Time: 2014-364T00:00:03.579 Stop Time: 2014-364T23:59:40.028
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
LPHAFULL0_2014365_01
Start Time: 2014-365T00:00:02.524 Stop Time: 2014-365T23:59:46.200
The data columns contain full time
resolution of LEMMS PHA data. The fill value for data in this file is
-1.0E38. These data are background subtracted, and thus occasionally
there will be negative values when the count rate falls below the
background level. Also, the uncertainties are based on the counting
statistics, and thus because of the background subtraction, the
uncertainties can be larger than the data value. The background levels
change over time and each channel's background level as a function of
time in counts/sec is listed in the MIMI calibration file (described
in the MIMI Data User Guide, the SIS for this dataset, and also in SIS
for the uncalibrated MIMI data). There are three types of channels
included in these averages: the A channels, the E channels and the F1
channels. The A channels measure ions, mostly protons. The E and F1
channels measure electrons. The MIMI instrument paper describes these
channels, as does the MIMI Data User Guide. For the A channels, channel
indices 8 through 62 are present (energies of 26-758 keV). For the E
channels, indices 15 to 62 (20-410 keV), and for F1, 26 through 59
(206-1717 keV). Note that a subset of the available PHA channels are
typically used for science analysis, and only these channels are plotted
here. The dataset catalog file details the reasons for this.
Essentially, the efficiencies are unknown or uncertain for omitted channels.
Following the data are columns describing certain geometric parameters such
as the position of Cassini in the SZS and SZO frames. Also included are the
pitch angle of the LET.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench