• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Cassini >> MIMI
CASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE View Errata Order Volume Toggle viewing into brief mode
CO-S-MIMI-4-LEMMS-CALIB-V1.0 PDS 3      CERTIFIED
Start Time: 2004-01-01 08:00:00 - Stop Time: 2017-09-16 10:00:00
This contains calibrated Saturn tour data collected by the LEMMS sensor of the MIMI instrument aboard the Cassini spacecraft for the Cassini mission.
This contains calibrated Saturn tour data collected by the LEMMS sensor of the MIMI instrument aboard the Cassini spacecraft for the Cassini mission.    less ...
Citiation Information
Author Vandegriff J., Kusterer M.B.
TitleCASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE
PublisherNASA Planetary Data System
Publication Year 2018
doi https://doi.org/10.17189/1519608
Top/ DATA/ LPHAAVG0_1MIN/ 2016 / click here to download folders and files
LPHAAVG0_1MIN_2016001_02
Start Time: 2016-001T00:00 Stop Time: 2016-002T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016002_02
Start Time: 2016-002T00:00 Stop Time: 2016-003T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016003_02
Start Time: 2016-003T00:00 Stop Time: 2016-004T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016004_02
Start Time: 2016-004T00:00 Stop Time: 2016-005T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016005_02
Start Time: 2016-005T00:00 Stop Time: 2016-006T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016006_02
Start Time: 2016-006T00:00 Stop Time: 2016-007T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016007_02
Start Time: 2016-007T00:00 Stop Time: 2016-008T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016008_02
Start Time: 2016-008T00:00 Stop Time: 2016-009T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016009_02
Start Time: 2016-009T00:00 Stop Time: 2016-010T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016010_02
Start Time: 2016-010T00:00 Stop Time: 2016-011T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016011_02
Start Time: 2016-011T00:00 Stop Time: 2016-012T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016012_02
Start Time: 2016-012T00:00 Stop Time: 2016-013T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016013_02
Start Time: 2016-013T00:00 Stop Time: 2016-014T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016014_02
Start Time: 2016-014T00:00 Stop Time: 2016-015T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016015_02
Start Time: 2016-015T00:00 Stop Time: 2016-016T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016016_02
Start Time: 2016-016T00:00 Stop Time: 2016-017T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016017_02
Start Time: 2016-017T00:00 Stop Time: 2016-018T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016018_02
Start Time: 2016-018T00:00 Stop Time: 2016-019T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016019_02
Start Time: 2016-019T00:00 Stop Time: 2016-020T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016020_02
Start Time: 2016-020T00:00 Stop Time: 2016-021T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016021_02
Start Time: 2016-021T00:00 Stop Time: 2016-022T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016022_02
Start Time: 2016-022T00:00 Stop Time: 2016-023T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016023_02
Start Time: 2016-023T00:00 Stop Time: 2016-024T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016024_02
Start Time: 2016-024T00:00 Stop Time: 2016-025T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016025_02
Start Time: 2016-025T00:00 Stop Time: 2016-026T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016026_02
Start Time: 2016-026T00:00 Stop Time: 2016-027T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016027_02
Start Time: 2016-027T00:00 Stop Time: 2016-028T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016028_02
Start Time: 2016-028T00:00 Stop Time: 2016-029T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016029_02
Start Time: 2016-029T00:00 Stop Time: 2016-030T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016030_02
Start Time: 2016-030T00:00 Stop Time: 2016-031T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016031_02
Start Time: 2016-031T00:00 Stop Time: 2016-032T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016032_02
Start Time: 2016-032T00:00 Stop Time: 2016-033T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016033_02
Start Time: 2016-033T00:00 Stop Time: 2016-034T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016034_02
Start Time: 2016-034T00:00 Stop Time: 2016-035T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016035_02
Start Time: 2016-035T00:00 Stop Time: 2016-036T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016036_02
Start Time: 2016-036T00:00 Stop Time: 2016-037T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016037_02
Start Time: 2016-037T00:00 Stop Time: 2016-038T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016038_02
Start Time: 2016-038T00:00 Stop Time: 2016-039T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016039_02
Start Time: 2016-039T00:00 Stop Time: 2016-040T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016040_02
Start Time: 2016-040T00:00 Stop Time: 2016-041T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016041_02
Start Time: 2016-041T00:00 Stop Time: 2016-042T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016042_02
Start Time: 2016-042T00:00 Stop Time: 2016-043T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016043_02
Start Time: 2016-043T00:00 Stop Time: 2016-044T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016044_02
Start Time: 2016-044T00:00 Stop Time: 2016-045T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016045_02
Start Time: 2016-045T00:00 Stop Time: 2016-046T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016046_02
Start Time: 2016-046T00:00 Stop Time: 2016-047T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016047_02
Start Time: 2016-047T00:00 Stop Time: 2016-048T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016048_02
Start Time: 2016-048T00:00 Stop Time: 2016-049T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016049_02
Start Time: 2016-049T00:00 Stop Time: 2016-050T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016050_02
Start Time: 2016-050T00:00 Stop Time: 2016-051T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016051_02
Start Time: 2016-051T00:00 Stop Time: 2016-052T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016052_02
Start Time: 2016-052T00:00 Stop Time: 2016-053T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016053_02
Start Time: 2016-053T00:00 Stop Time: 2016-054T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016054_02
Start Time: 2016-054T00:00 Stop Time: 2016-055T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016055_02
Start Time: 2016-055T00:00 Stop Time: 2016-056T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016056_02
Start Time: 2016-056T00:00 Stop Time: 2016-057T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016057_02
Start Time: 2016-057T00:00 Stop Time: 2016-058T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016058_02
Start Time: 2016-058T00:00 Stop Time: 2016-059T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016059_02
Start Time: 2016-059T00:00 Stop Time: 2016-060T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016060_02
Start Time: 2016-060T00:00 Stop Time: 2016-061T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016061_02
Start Time: 2016-061T00:00 Stop Time: 2016-062T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016062_02
Start Time: 2016-062T00:00 Stop Time: 2016-063T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016063_02
Start Time: 2016-063T00:00 Stop Time: 2016-064T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016064_02
Start Time: 2016-064T00:00 Stop Time: 2016-065T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016065_02
Start Time: 2016-065T00:00 Stop Time: 2016-066T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016066_02
Start Time: 2016-066T00:00 Stop Time: 2016-067T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016068_02
Start Time: 2016-068T00:00 Stop Time: 2016-069T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016069_02
Start Time: 2016-069T00:00 Stop Time: 2016-070T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016070_02
Start Time: 2016-070T00:00 Stop Time: 2016-071T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016071_02
Start Time: 2016-071T00:00 Stop Time: 2016-072T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016072_02
Start Time: 2016-072T00:00 Stop Time: 2016-073T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016073_02
Start Time: 2016-073T00:00 Stop Time: 2016-074T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016074_02
Start Time: 2016-074T00:00 Stop Time: 2016-075T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016075_02
Start Time: 2016-075T00:00 Stop Time: 2016-076T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016076_02
Start Time: 2016-076T00:00 Stop Time: 2016-077T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016077_02
Start Time: 2016-077T00:00 Stop Time: 2016-078T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016078_02
Start Time: 2016-078T00:00 Stop Time: 2016-079T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016079_02
Start Time: 2016-079T00:00 Stop Time: 2016-080T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016080_02
Start Time: 2016-080T00:00 Stop Time: 2016-081T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016081_02
Start Time: 2016-081T00:00 Stop Time: 2016-082T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016082_02
Start Time: 2016-082T00:00 Stop Time: 2016-083T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016083_02
Start Time: 2016-083T00:00 Stop Time: 2016-084T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016084_02
Start Time: 2016-084T00:00 Stop Time: 2016-085T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016085_02
Start Time: 2016-085T00:00 Stop Time: 2016-086T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016086_02
Start Time: 2016-086T00:00 Stop Time: 2016-087T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016087_02
Start Time: 2016-087T00:00 Stop Time: 2016-088T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016088_02
Start Time: 2016-088T00:00 Stop Time: 2016-089T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016089_02
Start Time: 2016-089T00:00 Stop Time: 2016-090T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016090_02
Start Time: 2016-090T00:00 Stop Time: 2016-091T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016091_02
Start Time: 2016-091T00:00 Stop Time: 2016-092T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016092_02
Start Time: 2016-092T00:00 Stop Time: 2016-093T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016093_02
Start Time: 2016-093T00:00 Stop Time: 2016-094T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016094_02
Start Time: 2016-094T00:00 Stop Time: 2016-095T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016095_02
Start Time: 2016-095T00:00 Stop Time: 2016-096T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016096_02
Start Time: 2016-096T00:00 Stop Time: 2016-097T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016097_02
Start Time: 2016-097T00:00 Stop Time: 2016-098T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016098_02
Start Time: 2016-098T00:00 Stop Time: 2016-099T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016099_02
Start Time: 2016-099T00:00 Stop Time: 2016-100T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016100_02
Start Time: 2016-100T00:00 Stop Time: 2016-101T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016101_02
Start Time: 2016-101T00:00 Stop Time: 2016-102T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016102_02
Start Time: 2016-102T00:00 Stop Time: 2016-103T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016103_02
Start Time: 2016-103T00:00 Stop Time: 2016-104T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016104_02
Start Time: 2016-104T00:00 Stop Time: 2016-105T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016105_02
Start Time: 2016-105T00:00 Stop Time: 2016-106T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016106_02
Start Time: 2016-106T00:00 Stop Time: 2016-107T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016107_02
Start Time: 2016-107T00:00 Stop Time: 2016-108T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016108_02
Start Time: 2016-108T00:00 Stop Time: 2016-109T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016109_02
Start Time: 2016-109T00:00 Stop Time: 2016-110T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016110_02
Start Time: 2016-110T00:00 Stop Time: 2016-111T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016111_02
Start Time: 2016-111T00:00 Stop Time: 2016-112T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016112_02
Start Time: 2016-112T00:00 Stop Time: 2016-113T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016113_02
Start Time: 2016-113T00:00 Stop Time: 2016-114T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016114_02
Start Time: 2016-114T00:00 Stop Time: 2016-115T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016115_02
Start Time: 2016-115T00:00 Stop Time: 2016-116T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016116_02
Start Time: 2016-116T00:00 Stop Time: 2016-117T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016117_02
Start Time: 2016-117T00:00 Stop Time: 2016-118T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016118_02
Start Time: 2016-118T00:00 Stop Time: 2016-119T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016119_02
Start Time: 2016-119T00:00 Stop Time: 2016-120T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016120_02
Start Time: 2016-120T00:00 Stop Time: 2016-121T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016121_02
Start Time: 2016-121T00:00 Stop Time: 2016-122T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016122_02
Start Time: 2016-122T00:00 Stop Time: 2016-123T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016123_02
Start Time: 2016-123T00:00 Stop Time: 2016-124T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016124_02
Start Time: 2016-124T00:00 Stop Time: 2016-125T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016125_02
Start Time: 2016-125T00:00 Stop Time: 2016-126T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016126_02
Start Time: 2016-126T00:00 Stop Time: 2016-127T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016127_02
Start Time: 2016-127T00:00 Stop Time: 2016-128T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016128_02
Start Time: 2016-128T00:00 Stop Time: 2016-129T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016129_02
Start Time: 2016-129T00:00 Stop Time: 2016-130T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016130_02
Start Time: 2016-130T00:00 Stop Time: 2016-131T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016131_02
Start Time: 2016-131T00:00 Stop Time: 2016-132T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016132_02
Start Time: 2016-132T00:00 Stop Time: 2016-133T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016133_02
Start Time: 2016-133T00:00 Stop Time: 2016-134T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016134_02
Start Time: 2016-134T00:00 Stop Time: 2016-135T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016135_02
Start Time: 2016-135T00:00 Stop Time: 2016-136T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016136_02
Start Time: 2016-136T00:00 Stop Time: 2016-137T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016137_02
Start Time: 2016-137T00:00 Stop Time: 2016-138T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016138_02
Start Time: 2016-138T00:00 Stop Time: 2016-139T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016139_02
Start Time: 2016-139T00:00 Stop Time: 2016-140T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016140_02
Start Time: 2016-140T00:00 Stop Time: 2016-141T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016141_02
Start Time: 2016-141T00:00 Stop Time: 2016-142T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016142_02
Start Time: 2016-142T00:00 Stop Time: 2016-143T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016143_02
Start Time: 2016-143T00:00 Stop Time: 2016-144T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016144_02
Start Time: 2016-144T00:00 Stop Time: 2016-145T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016150_02
Start Time: 2016-150T00:00 Stop Time: 2016-151T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016151_02
Start Time: 2016-151T00:00 Stop Time: 2016-152T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016152_02
Start Time: 2016-152T00:00 Stop Time: 2016-153T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016153_02
Start Time: 2016-153T00:00 Stop Time: 2016-154T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016154_02
Start Time: 2016-154T00:00 Stop Time: 2016-155T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016155_02
Start Time: 2016-155T00:00 Stop Time: 2016-156T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016156_02
Start Time: 2016-156T00:00 Stop Time: 2016-157T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016157_02
Start Time: 2016-157T00:00 Stop Time: 2016-158T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016158_02
Start Time: 2016-158T00:00 Stop Time: 2016-159T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016159_02
Start Time: 2016-159T00:00 Stop Time: 2016-160T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016160_02
Start Time: 2016-160T00:00 Stop Time: 2016-161T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016161_02
Start Time: 2016-161T00:00 Stop Time: 2016-162T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016162_02
Start Time: 2016-162T00:00 Stop Time: 2016-163T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016163_02
Start Time: 2016-163T00:00 Stop Time: 2016-164T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016164_02
Start Time: 2016-164T00:00 Stop Time: 2016-165T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016165_02
Start Time: 2016-165T00:00 Stop Time: 2016-166T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016166_02
Start Time: 2016-166T00:00 Stop Time: 2016-167T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016167_02
Start Time: 2016-167T00:00 Stop Time: 2016-168T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016168_02
Start Time: 2016-168T00:00 Stop Time: 2016-169T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016169_02
Start Time: 2016-169T00:00 Stop Time: 2016-170T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016170_02
Start Time: 2016-170T00:00 Stop Time: 2016-171T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016171_02
Start Time: 2016-171T00:00 Stop Time: 2016-172T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016172_02
Start Time: 2016-172T00:00 Stop Time: 2016-173T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016173_02
Start Time: 2016-173T00:00 Stop Time: 2016-174T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016174_02
Start Time: 2016-174T00:00 Stop Time: 2016-175T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016175_02
Start Time: 2016-175T00:00 Stop Time: 2016-176T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016176_02
Start Time: 2016-176T00:00 Stop Time: 2016-177T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016177_02
Start Time: 2016-177T00:00 Stop Time: 2016-178T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016178_02
Start Time: 2016-178T00:00 Stop Time: 2016-179T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016179_02
Start Time: 2016-179T00:00 Stop Time: 2016-180T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016180_02
Start Time: 2016-180T00:00 Stop Time: 2016-181T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016181_02
Start Time: 2016-181T00:00 Stop Time: 2016-182T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016182_02
Start Time: 2016-182T00:00 Stop Time: 2016-183T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016183_02
Start Time: 2016-183T00:00 Stop Time: 2016-184T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016184_02
Start Time: 2016-184T00:00 Stop Time: 2016-185T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016185_02
Start Time: 2016-185T00:00 Stop Time: 2016-186T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016186_02
Start Time: 2016-186T00:00 Stop Time: 2016-187T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016187_02
Start Time: 2016-187T00:00 Stop Time: 2016-188T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016188_02
Start Time: 2016-188T00:00 Stop Time: 2016-189T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016189_02
Start Time: 2016-189T00:00 Stop Time: 2016-190T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016190_02
Start Time: 2016-190T00:00 Stop Time: 2016-191T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016191_02
Start Time: 2016-191T00:00 Stop Time: 2016-192T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016192_02
Start Time: 2016-192T00:00 Stop Time: 2016-193T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016193_02
Start Time: 2016-193T00:00 Stop Time: 2016-194T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016194_02
Start Time: 2016-194T00:00 Stop Time: 2016-195T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016195_02
Start Time: 2016-195T00:00 Stop Time: 2016-196T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016196_02
Start Time: 2016-196T00:00 Stop Time: 2016-197T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016197_02
Start Time: 2016-197T00:00 Stop Time: 2016-198T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016198_02
Start Time: 2016-198T00:00 Stop Time: 2016-199T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016199_02
Start Time: 2016-199T00:00 Stop Time: 2016-200T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016200_02
Start Time: 2016-200T00:00 Stop Time: 2016-201T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016201_02
Start Time: 2016-201T00:00 Stop Time: 2016-202T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016202_02
Start Time: 2016-202T00:00 Stop Time: 2016-203T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016203_02
Start Time: 2016-203T00:00 Stop Time: 2016-204T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016204_02
Start Time: 2016-204T00:00 Stop Time: 2016-205T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016205_02
Start Time: 2016-205T00:00 Stop Time: 2016-206T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016206_02
Start Time: 2016-206T00:00 Stop Time: 2016-207T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016207_02
Start Time: 2016-207T00:00 Stop Time: 2016-208T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016208_02
Start Time: 2016-208T00:00 Stop Time: 2016-209T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016209_02
Start Time: 2016-209T00:00 Stop Time: 2016-210T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016210_02
Start Time: 2016-210T00:00 Stop Time: 2016-211T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016211_02
Start Time: 2016-211T00:00 Stop Time: 2016-212T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016212_02
Start Time: 2016-212T00:00 Stop Time: 2016-213T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016213_02
Start Time: 2016-213T00:00 Stop Time: 2016-214T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016214_02
Start Time: 2016-214T00:00 Stop Time: 2016-215T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016215_02
Start Time: 2016-215T00:00 Stop Time: 2016-216T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016216_02
Start Time: 2016-216T00:00 Stop Time: 2016-217T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016217_02
Start Time: 2016-217T00:00 Stop Time: 2016-218T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016218_02
Start Time: 2016-218T00:00 Stop Time: 2016-219T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016219_02
Start Time: 2016-219T00:00 Stop Time: 2016-220T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016220_02
Start Time: 2016-220T00:00 Stop Time: 2016-221T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016221_02
Start Time: 2016-221T00:00 Stop Time: 2016-222T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016222_02
Start Time: 2016-222T00:00 Stop Time: 2016-223T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016223_02
Start Time: 2016-223T00:00 Stop Time: 2016-224T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016224_02
Start Time: 2016-224T00:00 Stop Time: 2016-225T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016225_02
Start Time: 2016-225T00:00 Stop Time: 2016-226T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016226_02
Start Time: 2016-226T00:00 Stop Time: 2016-227T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016227_02
Start Time: 2016-227T00:00 Stop Time: 2016-228T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016228_02
Start Time: 2016-228T00:00 Stop Time: 2016-229T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016229_02
Start Time: 2016-229T00:00 Stop Time: 2016-230T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016230_02
Start Time: 2016-230T00:00 Stop Time: 2016-231T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016231_02
Start Time: 2016-231T00:00 Stop Time: 2016-232T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016232_02
Start Time: 2016-232T00:00 Stop Time: 2016-233T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016233_02
Start Time: 2016-233T00:00 Stop Time: 2016-234T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016234_02
Start Time: 2016-234T00:00 Stop Time: 2016-235T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016235_02
Start Time: 2016-235T00:00 Stop Time: 2016-236T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016236_02
Start Time: 2016-236T00:00 Stop Time: 2016-237T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016237_02
Start Time: 2016-237T00:00 Stop Time: 2016-238T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016238_02
Start Time: 2016-238T00:00 Stop Time: 2016-239T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016239_02
Start Time: 2016-239T00:00 Stop Time: 2016-240T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016240_02
Start Time: 2016-240T00:00 Stop Time: 2016-241T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016241_02
Start Time: 2016-241T00:00 Stop Time: 2016-242T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016242_02
Start Time: 2016-242T00:00 Stop Time: 2016-243T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016243_02
Start Time: 2016-243T00:00 Stop Time: 2016-244T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016244_02
Start Time: 2016-244T00:00 Stop Time: 2016-245T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016245_02
Start Time: 2016-245T00:00 Stop Time: 2016-246T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016246_02
Start Time: 2016-246T00:00 Stop Time: 2016-247T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016247_02
Start Time: 2016-247T00:00 Stop Time: 2016-248T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016248_02
Start Time: 2016-248T00:00 Stop Time: 2016-249T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016249_02
Start Time: 2016-249T00:00 Stop Time: 2016-250T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016250_02
Start Time: 2016-250T00:00 Stop Time: 2016-251T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016251_02
Start Time: 2016-251T00:00 Stop Time: 2016-252T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016252_02
Start Time: 2016-252T00:00 Stop Time: 2016-253T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016253_02
Start Time: 2016-253T00:00 Stop Time: 2016-254T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016254_02
Start Time: 2016-254T00:00 Stop Time: 2016-255T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016255_02
Start Time: 2016-255T00:00 Stop Time: 2016-256T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016256_02
Start Time: 2016-256T00:00 Stop Time: 2016-257T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016257_02
Start Time: 2016-257T00:00 Stop Time: 2016-258T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016258_02
Start Time: 2016-258T00:00 Stop Time: 2016-259T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016259_02
Start Time: 2016-259T00:00 Stop Time: 2016-260T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016260_02
Start Time: 2016-260T00:00 Stop Time: 2016-261T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016261_02
Start Time: 2016-261T00:00 Stop Time: 2016-262T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016262_02
Start Time: 2016-262T00:00 Stop Time: 2016-263T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016263_02
Start Time: 2016-263T00:00 Stop Time: 2016-264T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016264_02
Start Time: 2016-264T00:00 Stop Time: 2016-265T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016265_02
Start Time: 2016-265T00:00 Stop Time: 2016-266T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016266_02
Start Time: 2016-266T00:00 Stop Time: 2016-267T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016267_02
Start Time: 2016-267T00:00 Stop Time: 2016-268T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016268_02
Start Time: 2016-268T00:00 Stop Time: 2016-269T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016269_02
Start Time: 2016-269T00:00 Stop Time: 2016-270T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016270_02
Start Time: 2016-270T00:00 Stop Time: 2016-271T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016271_02
Start Time: 2016-271T00:00 Stop Time: 2016-272T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016272_02
Start Time: 2016-272T00:00 Stop Time: 2016-273T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016273_02
Start Time: 2016-273T00:00 Stop Time: 2016-274T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016274_02
Start Time: 2016-274T00:00 Stop Time: 2016-275T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016275_02
Start Time: 2016-275T00:00 Stop Time: 2016-276T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016276_02
Start Time: 2016-276T00:00 Stop Time: 2016-277T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016277_02
Start Time: 2016-277T00:00 Stop Time: 2016-278T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016278_02
Start Time: 2016-278T00:00 Stop Time: 2016-279T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016279_02
Start Time: 2016-279T00:00 Stop Time: 2016-280T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016280_02
Start Time: 2016-280T00:00 Stop Time: 2016-281T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016281_02
Start Time: 2016-281T00:00 Stop Time: 2016-282T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016282_02
Start Time: 2016-282T00:00 Stop Time: 2016-283T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016283_02
Start Time: 2016-283T00:00 Stop Time: 2016-284T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016284_02
Start Time: 2016-284T00:00 Stop Time: 2016-285T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016285_02
Start Time: 2016-285T00:00 Stop Time: 2016-286T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016286_02
Start Time: 2016-286T00:00 Stop Time: 2016-287T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016287_02
Start Time: 2016-287T00:00 Stop Time: 2016-288T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016288_02
Start Time: 2016-288T00:00 Stop Time: 2016-289T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016289_02
Start Time: 2016-289T00:00 Stop Time: 2016-290T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016290_02
Start Time: 2016-290T00:00 Stop Time: 2016-291T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016291_02
Start Time: 2016-291T00:00 Stop Time: 2016-292T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016292_02
Start Time: 2016-292T00:00 Stop Time: 2016-293T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016293_02
Start Time: 2016-293T00:00 Stop Time: 2016-294T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016294_02
Start Time: 2016-294T00:00 Stop Time: 2016-295T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016295_02
Start Time: 2016-295T00:00 Stop Time: 2016-296T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016296_02
Start Time: 2016-296T00:00 Stop Time: 2016-297T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016297_02
Start Time: 2016-297T00:00 Stop Time: 2016-298T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016298_02
Start Time: 2016-298T00:00 Stop Time: 2016-299T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016299_02
Start Time: 2016-299T00:00 Stop Time: 2016-300T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016300_02
Start Time: 2016-300T00:00 Stop Time: 2016-301T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016301_02
Start Time: 2016-301T00:00 Stop Time: 2016-302T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016302_02
Start Time: 2016-302T00:00 Stop Time: 2016-303T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016303_02
Start Time: 2016-303T00:00 Stop Time: 2016-304T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016304_02
Start Time: 2016-304T00:00 Stop Time: 2016-305T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016305_02
Start Time: 2016-305T00:00 Stop Time: 2016-306T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016306_02
Start Time: 2016-306T00:00 Stop Time: 2016-307T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016307_02
Start Time: 2016-307T00:00 Stop Time: 2016-308T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016308_02
Start Time: 2016-308T00:00 Stop Time: 2016-309T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016309_02
Start Time: 2016-309T00:00 Stop Time: 2016-310T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016310_02
Start Time: 2016-310T00:00 Stop Time: 2016-311T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016311_02
Start Time: 2016-311T00:00 Stop Time: 2016-312T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016312_02
Start Time: 2016-312T00:00 Stop Time: 2016-313T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016313_02
Start Time: 2016-313T00:00 Stop Time: 2016-314T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016314_02
Start Time: 2016-314T00:00 Stop Time: 2016-315T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016315_02
Start Time: 2016-315T00:00 Stop Time: 2016-316T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016316_02
Start Time: 2016-316T00:00 Stop Time: 2016-317T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016317_02
Start Time: 2016-317T00:00 Stop Time: 2016-318T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016318_02
Start Time: 2016-318T00:00 Stop Time: 2016-319T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016319_02
Start Time: 2016-319T00:00 Stop Time: 2016-320T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016320_02
Start Time: 2016-320T00:00 Stop Time: 2016-321T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016321_02
Start Time: 2016-321T00:00 Stop Time: 2016-322T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016322_02
Start Time: 2016-322T00:00 Stop Time: 2016-323T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016323_02
Start Time: 2016-323T00:00 Stop Time: 2016-324T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016324_02
Start Time: 2016-324T00:00 Stop Time: 2016-325T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016325_02
Start Time: 2016-325T00:00 Stop Time: 2016-326T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016326_02
Start Time: 2016-326T00:00 Stop Time: 2016-327T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016327_02
Start Time: 2016-327T00:00 Stop Time: 2016-328T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016328_02
Start Time: 2016-328T00:00 Stop Time: 2016-329T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016329_02
Start Time: 2016-329T00:00 Stop Time: 2016-330T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016330_02
Start Time: 2016-330T00:00 Stop Time: 2016-331T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016331_02
Start Time: 2016-331T00:00 Stop Time: 2016-332T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016332_02
Start Time: 2016-332T00:00 Stop Time: 2016-333T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016333_02
Start Time: 2016-333T00:00 Stop Time: 2016-334T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016334_02
Start Time: 2016-334T00:00 Stop Time: 2016-335T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016335_02
Start Time: 2016-335T00:00 Stop Time: 2016-336T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016336_02
Start Time: 2016-336T00:00 Stop Time: 2016-337T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016337_02
Start Time: 2016-337T00:00 Stop Time: 2016-338T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016338_02
Start Time: 2016-338T00:00 Stop Time: 2016-339T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016339_02
Start Time: 2016-339T00:00 Stop Time: 2016-340T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016340_02
Start Time: 2016-340T00:00 Stop Time: 2016-341T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016341_02
Start Time: 2016-341T00:00 Stop Time: 2016-342T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016342_02
Start Time: 2016-342T00:00 Stop Time: 2016-343T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016343_02
Start Time: 2016-343T00:00 Stop Time: 2016-344T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016344_02
Start Time: 2016-344T00:00 Stop Time: 2016-345T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016345_02
Start Time: 2016-345T00:00 Stop Time: 2016-346T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016346_02
Start Time: 2016-346T00:00 Stop Time: 2016-347T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016347_02
Start Time: 2016-347T00:00 Stop Time: 2016-348T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016348_02
Start Time: 2016-348T00:00 Stop Time: 2016-349T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016349_02
Start Time: 2016-349T00:00 Stop Time: 2016-350T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016350_02
Start Time: 2016-350T00:00 Stop Time: 2016-351T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016351_02
Start Time: 2016-351T00:00 Stop Time: 2016-352T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016352_02
Start Time: 2016-352T00:00 Stop Time: 2016-353T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016353_02
Start Time: 2016-353T00:00 Stop Time: 2016-354T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016354_02
Start Time: 2016-354T00:00 Stop Time: 2016-355T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016355_02
Start Time: 2016-355T00:00 Stop Time: 2016-356T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016356_02
Start Time: 2016-356T00:00 Stop Time: 2016-357T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016357_02
Start Time: 2016-357T00:00 Stop Time: 2016-358T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016358_02
Start Time: 2016-358T00:00 Stop Time: 2016-359T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016359_02
Start Time: 2016-359T00:00 Stop Time: 2016-360T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016360_02
Start Time: 2016-360T00:00 Stop Time: 2016-361T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016361_02
Start Time: 2016-361T00:00 Stop Time: 2016-362T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016362_02
Start Time: 2016-362T00:00 Stop Time: 2016-363T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016363_02
Start Time: 2016-363T00:00 Stop Time: 2016-364T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016364_02
Start Time: 2016-364T00:00 Stop Time: 2016-365T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016365_02
Start Time: 2016-365T00:00 Stop Time: 2016-366T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2016366_02
Start Time: 2016-366T00:00 Stop Time: 2017-001T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench