• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Cassini >> MIMI
CASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE View Errata Order Volume Toggle viewing into brief mode
CO-S-MIMI-4-LEMMS-CALIB-V1.0 PDS 3      CERTIFIED
Start Time: 2004-01-01 08:00:00 - Stop Time: 2017-09-16 10:00:00
This contains calibrated Saturn tour data collected by the LEMMS sensor of the MIMI instrument aboard the Cassini spacecraft for the Cassini mission.
This contains calibrated Saturn tour data collected by the LEMMS sensor of the MIMI instrument aboard the Cassini spacecraft for the Cassini mission.    less ...
Citiation Information
Author Vandegriff J., Kusterer M.B.
TitleCASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE
PublisherNASA Planetary Data System
Publication Year 2018
doi https://doi.org/10.17189/1519608
Top/ DATA/ LPHAAVG0_1MIN/ 2013 / click here to download folders and files
LPHAAVG0_1MIN_2013001_02
Start Time: 2013-001T00:00 Stop Time: 2013-002T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013002_02
Start Time: 2013-002T00:00 Stop Time: 2013-003T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013003_02
Start Time: 2013-003T00:00 Stop Time: 2013-004T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013004_02
Start Time: 2013-004T00:00 Stop Time: 2013-005T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013005_02
Start Time: 2013-005T00:00 Stop Time: 2013-006T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013006_02
Start Time: 2013-006T00:00 Stop Time: 2013-007T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013007_02
Start Time: 2013-007T00:00 Stop Time: 2013-008T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013008_02
Start Time: 2013-008T00:00 Stop Time: 2013-009T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013009_02
Start Time: 2013-009T00:00 Stop Time: 2013-010T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013010_02
Start Time: 2013-010T00:00 Stop Time: 2013-011T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013011_02
Start Time: 2013-011T00:00 Stop Time: 2013-012T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013012_02
Start Time: 2013-012T00:00 Stop Time: 2013-013T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013013_02
Start Time: 2013-013T00:00 Stop Time: 2013-014T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013014_02
Start Time: 2013-014T00:00 Stop Time: 2013-015T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013015_02
Start Time: 2013-015T00:00 Stop Time: 2013-016T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013016_02
Start Time: 2013-016T00:00 Stop Time: 2013-017T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013017_02
Start Time: 2013-017T00:00 Stop Time: 2013-018T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013018_02
Start Time: 2013-018T00:00 Stop Time: 2013-019T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013019_02
Start Time: 2013-019T00:00 Stop Time: 2013-020T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013020_02
Start Time: 2013-020T00:00 Stop Time: 2013-021T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013021_02
Start Time: 2013-021T00:00 Stop Time: 2013-022T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013022_02
Start Time: 2013-022T00:00 Stop Time: 2013-023T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013023_02
Start Time: 2013-023T00:00 Stop Time: 2013-024T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013024_02
Start Time: 2013-024T00:00 Stop Time: 2013-025T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013025_02
Start Time: 2013-025T00:00 Stop Time: 2013-026T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013026_02
Start Time: 2013-026T00:00 Stop Time: 2013-027T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013027_02
Start Time: 2013-027T00:00 Stop Time: 2013-028T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013028_02
Start Time: 2013-028T00:00 Stop Time: 2013-029T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013029_02
Start Time: 2013-029T00:00 Stop Time: 2013-030T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013030_02
Start Time: 2013-030T00:00 Stop Time: 2013-031T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013031_02
Start Time: 2013-031T00:00 Stop Time: 2013-032T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013032_02
Start Time: 2013-032T00:00 Stop Time: 2013-033T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013033_02
Start Time: 2013-033T00:00 Stop Time: 2013-034T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013034_02
Start Time: 2013-034T00:00 Stop Time: 2013-035T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013035_02
Start Time: 2013-035T00:00 Stop Time: 2013-036T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013036_02
Start Time: 2013-036T00:00 Stop Time: 2013-037T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013037_02
Start Time: 2013-037T00:00 Stop Time: 2013-038T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013038_02
Start Time: 2013-038T00:00 Stop Time: 2013-039T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013039_02
Start Time: 2013-039T00:00 Stop Time: 2013-040T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013040_02
Start Time: 2013-040T00:00 Stop Time: 2013-041T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013041_02
Start Time: 2013-041T00:00 Stop Time: 2013-042T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013042_02
Start Time: 2013-042T00:00 Stop Time: 2013-043T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013043_02
Start Time: 2013-043T00:00 Stop Time: 2013-044T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013044_02
Start Time: 2013-044T00:00 Stop Time: 2013-045T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013045_02
Start Time: 2013-045T00:00 Stop Time: 2013-046T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013046_02
Start Time: 2013-046T00:00 Stop Time: 2013-047T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013047_02
Start Time: 2013-047T00:00 Stop Time: 2013-048T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013048_02
Start Time: 2013-048T00:00 Stop Time: 2013-049T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013049_02
Start Time: 2013-049T00:00 Stop Time: 2013-050T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013050_02
Start Time: 2013-050T00:00 Stop Time: 2013-051T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013051_02
Start Time: 2013-051T00:00 Stop Time: 2013-052T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013052_02
Start Time: 2013-052T00:00 Stop Time: 2013-053T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013053_02
Start Time: 2013-053T00:00 Stop Time: 2013-054T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013054_02
Start Time: 2013-054T00:00 Stop Time: 2013-055T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013055_02
Start Time: 2013-055T00:00 Stop Time: 2013-056T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013056_02
Start Time: 2013-056T00:00 Stop Time: 2013-057T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013057_02
Start Time: 2013-057T00:00 Stop Time: 2013-058T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013058_02
Start Time: 2013-058T00:00 Stop Time: 2013-059T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013059_02
Start Time: 2013-059T00:00 Stop Time: 2013-060T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013060_02
Start Time: 2013-060T00:00 Stop Time: 2013-061T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013061_02
Start Time: 2013-061T00:00 Stop Time: 2013-062T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013062_02
Start Time: 2013-062T00:00 Stop Time: 2013-063T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013063_02
Start Time: 2013-063T00:00 Stop Time: 2013-064T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013064_02
Start Time: 2013-064T00:00 Stop Time: 2013-065T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013065_02
Start Time: 2013-065T00:00 Stop Time: 2013-066T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013066_02
Start Time: 2013-066T00:00 Stop Time: 2013-067T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013067_02
Start Time: 2013-067T00:00 Stop Time: 2013-068T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013068_02
Start Time: 2013-068T00:00 Stop Time: 2013-069T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013069_02
Start Time: 2013-069T00:00 Stop Time: 2013-070T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013070_02
Start Time: 2013-070T00:00 Stop Time: 2013-071T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013071_02
Start Time: 2013-071T00:00 Stop Time: 2013-072T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013072_02
Start Time: 2013-072T00:00 Stop Time: 2013-073T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013073_02
Start Time: 2013-073T00:00 Stop Time: 2013-074T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013074_02
Start Time: 2013-074T00:00 Stop Time: 2013-075T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013075_02
Start Time: 2013-075T00:00 Stop Time: 2013-076T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013076_02
Start Time: 2013-076T00:00 Stop Time: 2013-077T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013077_02
Start Time: 2013-077T00:00 Stop Time: 2013-078T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013078_02
Start Time: 2013-078T00:00 Stop Time: 2013-079T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013079_02
Start Time: 2013-079T00:00 Stop Time: 2013-080T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013080_02
Start Time: 2013-080T00:00 Stop Time: 2013-081T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013081_02
Start Time: 2013-081T00:00 Stop Time: 2013-082T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013082_02
Start Time: 2013-082T00:00 Stop Time: 2013-083T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013083_02
Start Time: 2013-083T00:00 Stop Time: 2013-084T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013084_02
Start Time: 2013-084T00:00 Stop Time: 2013-085T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013085_02
Start Time: 2013-085T00:00 Stop Time: 2013-086T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013086_02
Start Time: 2013-086T00:00 Stop Time: 2013-087T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013087_02
Start Time: 2013-087T00:00 Stop Time: 2013-088T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013088_02
Start Time: 2013-088T00:00 Stop Time: 2013-089T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013089_02
Start Time: 2013-089T00:00 Stop Time: 2013-090T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013090_02
Start Time: 2013-090T00:00 Stop Time: 2013-091T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013091_02
Start Time: 2013-091T00:00 Stop Time: 2013-092T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013092_02
Start Time: 2013-092T00:00 Stop Time: 2013-093T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013093_02
Start Time: 2013-093T00:00 Stop Time: 2013-094T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013094_02
Start Time: 2013-094T00:00 Stop Time: 2013-095T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013095_02
Start Time: 2013-095T00:00 Stop Time: 2013-096T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013096_02
Start Time: 2013-096T00:00 Stop Time: 2013-097T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013097_02
Start Time: 2013-097T00:00 Stop Time: 2013-098T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013098_02
Start Time: 2013-098T00:00 Stop Time: 2013-099T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013099_02
Start Time: 2013-099T00:00 Stop Time: 2013-100T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013100_02
Start Time: 2013-100T00:00 Stop Time: 2013-101T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013101_02
Start Time: 2013-101T00:00 Stop Time: 2013-102T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013102_02
Start Time: 2013-102T00:00 Stop Time: 2013-103T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013103_02
Start Time: 2013-103T00:00 Stop Time: 2013-104T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013104_02
Start Time: 2013-104T00:00 Stop Time: 2013-105T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013105_02
Start Time: 2013-105T00:00 Stop Time: 2013-106T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013106_02
Start Time: 2013-106T00:00 Stop Time: 2013-107T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013107_02
Start Time: 2013-107T00:00 Stop Time: 2013-108T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013108_02
Start Time: 2013-108T00:00 Stop Time: 2013-109T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013109_02
Start Time: 2013-109T00:00 Stop Time: 2013-110T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013110_02
Start Time: 2013-110T00:00 Stop Time: 2013-111T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013111_02
Start Time: 2013-111T00:00 Stop Time: 2013-112T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013112_02
Start Time: 2013-112T00:00 Stop Time: 2013-113T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013113_02
Start Time: 2013-113T00:00 Stop Time: 2013-114T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013114_02
Start Time: 2013-114T00:00 Stop Time: 2013-115T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013115_02
Start Time: 2013-115T00:00 Stop Time: 2013-116T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013116_02
Start Time: 2013-116T00:00 Stop Time: 2013-117T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013117_02
Start Time: 2013-117T00:00 Stop Time: 2013-118T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013118_02
Start Time: 2013-118T00:00 Stop Time: 2013-119T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013119_02
Start Time: 2013-119T00:00 Stop Time: 2013-120T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013120_02
Start Time: 2013-120T00:00 Stop Time: 2013-121T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013121_02
Start Time: 2013-121T00:00 Stop Time: 2013-122T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013122_02
Start Time: 2013-122T00:00 Stop Time: 2013-123T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013123_02
Start Time: 2013-123T00:00 Stop Time: 2013-124T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013124_02
Start Time: 2013-124T00:00 Stop Time: 2013-125T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013125_02
Start Time: 2013-125T00:00 Stop Time: 2013-126T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013126_02
Start Time: 2013-126T00:00 Stop Time: 2013-127T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013127_02
Start Time: 2013-127T00:00 Stop Time: 2013-128T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013128_02
Start Time: 2013-128T00:00 Stop Time: 2013-129T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013129_02
Start Time: 2013-129T00:00 Stop Time: 2013-130T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013130_02
Start Time: 2013-130T00:00 Stop Time: 2013-131T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013131_02
Start Time: 2013-131T00:00 Stop Time: 2013-132T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013132_02
Start Time: 2013-132T00:00 Stop Time: 2013-133T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013133_02
Start Time: 2013-133T00:00 Stop Time: 2013-134T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013134_02
Start Time: 2013-134T00:00 Stop Time: 2013-135T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013135_02
Start Time: 2013-135T00:00 Stop Time: 2013-136T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013136_02
Start Time: 2013-136T00:00 Stop Time: 2013-137T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013137_02
Start Time: 2013-137T00:00 Stop Time: 2013-138T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013138_02
Start Time: 2013-138T00:00 Stop Time: 2013-139T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013139_02
Start Time: 2013-139T00:00 Stop Time: 2013-140T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013140_02
Start Time: 2013-140T00:00 Stop Time: 2013-141T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013141_02
Start Time: 2013-141T00:00 Stop Time: 2013-142T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013142_02
Start Time: 2013-142T00:00 Stop Time: 2013-143T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013143_02
Start Time: 2013-143T00:00 Stop Time: 2013-144T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013144_02
Start Time: 2013-144T00:00 Stop Time: 2013-145T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013145_02
Start Time: 2013-145T00:00 Stop Time: 2013-146T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013146_02
Start Time: 2013-146T00:00 Stop Time: 2013-147T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013147_02
Start Time: 2013-147T00:00 Stop Time: 2013-148T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013148_02
Start Time: 2013-148T00:00 Stop Time: 2013-149T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013149_02
Start Time: 2013-149T00:00 Stop Time: 2013-150T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013150_02
Start Time: 2013-150T00:00 Stop Time: 2013-151T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013151_02
Start Time: 2013-151T00:00 Stop Time: 2013-152T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013152_02
Start Time: 2013-152T00:00 Stop Time: 2013-153T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013153_02
Start Time: 2013-153T00:00 Stop Time: 2013-154T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013154_02
Start Time: 2013-154T00:00 Stop Time: 2013-155T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013155_02
Start Time: 2013-155T00:00 Stop Time: 2013-156T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013156_02
Start Time: 2013-156T00:00 Stop Time: 2013-157T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013157_02
Start Time: 2013-157T00:00 Stop Time: 2013-158T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013158_02
Start Time: 2013-158T00:00 Stop Time: 2013-159T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013159_02
Start Time: 2013-159T00:00 Stop Time: 2013-160T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013160_02
Start Time: 2013-160T00:00 Stop Time: 2013-161T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013161_02
Start Time: 2013-161T00:00 Stop Time: 2013-162T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013162_02
Start Time: 2013-162T00:00 Stop Time: 2013-163T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013163_02
Start Time: 2013-163T00:00 Stop Time: 2013-164T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013164_02
Start Time: 2013-164T00:00 Stop Time: 2013-165T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013165_02
Start Time: 2013-165T00:00 Stop Time: 2013-166T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013166_02
Start Time: 2013-166T00:00 Stop Time: 2013-167T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013167_02
Start Time: 2013-167T00:00 Stop Time: 2013-168T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013168_02
Start Time: 2013-168T00:00 Stop Time: 2013-169T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013169_02
Start Time: 2013-169T00:00 Stop Time: 2013-170T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013170_02
Start Time: 2013-170T00:00 Stop Time: 2013-171T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013171_02
Start Time: 2013-171T00:00 Stop Time: 2013-172T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013172_02
Start Time: 2013-172T00:00 Stop Time: 2013-173T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013173_02
Start Time: 2013-173T00:00 Stop Time: 2013-174T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013174_02
Start Time: 2013-174T00:00 Stop Time: 2013-175T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013175_02
Start Time: 2013-175T00:00 Stop Time: 2013-176T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013176_02
Start Time: 2013-176T00:00 Stop Time: 2013-177T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013177_02
Start Time: 2013-177T00:00 Stop Time: 2013-178T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013178_02
Start Time: 2013-178T00:00 Stop Time: 2013-179T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013179_02
Start Time: 2013-179T00:00 Stop Time: 2013-180T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013180_02
Start Time: 2013-180T00:00 Stop Time: 2013-181T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013181_02
Start Time: 2013-181T00:00 Stop Time: 2013-182T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013182_02
Start Time: 2013-182T00:00 Stop Time: 2013-183T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013183_02
Start Time: 2013-183T00:00 Stop Time: 2013-184T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013184_02
Start Time: 2013-184T00:00 Stop Time: 2013-185T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013185_02
Start Time: 2013-185T00:00 Stop Time: 2013-186T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013186_02
Start Time: 2013-186T00:00 Stop Time: 2013-187T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013187_02
Start Time: 2013-187T00:00 Stop Time: 2013-188T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013188_02
Start Time: 2013-188T00:00 Stop Time: 2013-189T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013189_02
Start Time: 2013-189T00:00 Stop Time: 2013-190T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013190_02
Start Time: 2013-190T00:00 Stop Time: 2013-191T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013191_02
Start Time: 2013-191T00:00 Stop Time: 2013-192T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013192_02
Start Time: 2013-192T00:00 Stop Time: 2013-193T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013193_02
Start Time: 2013-193T00:00 Stop Time: 2013-194T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013194_02
Start Time: 2013-194T00:00 Stop Time: 2013-195T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013195_02
Start Time: 2013-195T00:00 Stop Time: 2013-196T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013196_02
Start Time: 2013-196T00:00 Stop Time: 2013-197T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013197_02
Start Time: 2013-197T00:00 Stop Time: 2013-198T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013198_02
Start Time: 2013-198T00:00 Stop Time: 2013-199T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013199_02
Start Time: 2013-199T00:00 Stop Time: 2013-200T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013200_02
Start Time: 2013-200T00:00 Stop Time: 2013-201T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013201_02
Start Time: 2013-201T00:00 Stop Time: 2013-202T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013202_02
Start Time: 2013-202T00:00 Stop Time: 2013-203T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013203_02
Start Time: 2013-203T00:00 Stop Time: 2013-204T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013204_02
Start Time: 2013-204T00:00 Stop Time: 2013-205T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013205_02
Start Time: 2013-205T00:00 Stop Time: 2013-206T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013206_02
Start Time: 2013-206T00:00 Stop Time: 2013-207T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013207_02
Start Time: 2013-207T00:00 Stop Time: 2013-208T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013208_02
Start Time: 2013-208T00:00 Stop Time: 2013-209T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013209_02
Start Time: 2013-209T00:00 Stop Time: 2013-210T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013210_02
Start Time: 2013-210T00:00 Stop Time: 2013-211T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013211_02
Start Time: 2013-211T00:00 Stop Time: 2013-212T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013212_02
Start Time: 2013-212T00:00 Stop Time: 2013-213T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013213_02
Start Time: 2013-213T00:00 Stop Time: 2013-214T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013214_02
Start Time: 2013-214T00:00 Stop Time: 2013-215T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013215_02
Start Time: 2013-215T00:00 Stop Time: 2013-216T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013216_02
Start Time: 2013-216T00:00 Stop Time: 2013-217T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013217_02
Start Time: 2013-217T00:00 Stop Time: 2013-218T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013218_02
Start Time: 2013-218T00:00 Stop Time: 2013-219T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013219_02
Start Time: 2013-219T00:00 Stop Time: 2013-220T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013220_02
Start Time: 2013-220T00:00 Stop Time: 2013-221T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013221_02
Start Time: 2013-221T00:00 Stop Time: 2013-222T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013222_02
Start Time: 2013-222T00:00 Stop Time: 2013-223T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013223_02
Start Time: 2013-223T00:00 Stop Time: 2013-224T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013224_02
Start Time: 2013-224T00:00 Stop Time: 2013-225T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013225_02
Start Time: 2013-225T00:00 Stop Time: 2013-226T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013226_02
Start Time: 2013-226T00:00 Stop Time: 2013-227T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013227_02
Start Time: 2013-227T00:00 Stop Time: 2013-228T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013228_02
Start Time: 2013-228T00:00 Stop Time: 2013-229T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013229_02
Start Time: 2013-229T00:00 Stop Time: 2013-230T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013230_02
Start Time: 2013-230T00:00 Stop Time: 2013-231T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013231_02
Start Time: 2013-231T00:00 Stop Time: 2013-232T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013232_02
Start Time: 2013-232T00:00 Stop Time: 2013-233T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013233_02
Start Time: 2013-233T00:00 Stop Time: 2013-234T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013234_02
Start Time: 2013-234T00:00 Stop Time: 2013-235T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013235_02
Start Time: 2013-235T00:00 Stop Time: 2013-236T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013236_02
Start Time: 2013-236T00:00 Stop Time: 2013-237T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013237_02
Start Time: 2013-237T00:00 Stop Time: 2013-238T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013238_02
Start Time: 2013-238T00:00 Stop Time: 2013-239T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013239_02
Start Time: 2013-239T00:00 Stop Time: 2013-240T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013240_02
Start Time: 2013-240T00:00 Stop Time: 2013-241T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013241_02
Start Time: 2013-241T00:00 Stop Time: 2013-242T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013242_02
Start Time: 2013-242T00:00 Stop Time: 2013-243T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013243_02
Start Time: 2013-243T00:00 Stop Time: 2013-244T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013244_02
Start Time: 2013-244T00:00 Stop Time: 2013-245T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013245_02
Start Time: 2013-245T00:00 Stop Time: 2013-246T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013246_02
Start Time: 2013-246T00:00 Stop Time: 2013-247T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013247_02
Start Time: 2013-247T00:00 Stop Time: 2013-248T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013248_02
Start Time: 2013-248T00:00 Stop Time: 2013-249T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013249_02
Start Time: 2013-249T00:00 Stop Time: 2013-250T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013250_02
Start Time: 2013-250T00:00 Stop Time: 2013-251T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013251_02
Start Time: 2013-251T00:00 Stop Time: 2013-252T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013252_02
Start Time: 2013-252T00:00 Stop Time: 2013-253T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013253_02
Start Time: 2013-253T00:00 Stop Time: 2013-254T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013254_02
Start Time: 2013-254T00:00 Stop Time: 2013-255T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013255_02
Start Time: 2013-255T00:00 Stop Time: 2013-256T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013256_02
Start Time: 2013-256T00:00 Stop Time: 2013-257T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013257_02
Start Time: 2013-257T00:00 Stop Time: 2013-258T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013258_02
Start Time: 2013-258T00:00 Stop Time: 2013-259T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013259_02
Start Time: 2013-259T00:00 Stop Time: 2013-260T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013260_02
Start Time: 2013-260T00:00 Stop Time: 2013-261T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013261_02
Start Time: 2013-261T00:00 Stop Time: 2013-262T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013262_02
Start Time: 2013-262T00:00 Stop Time: 2013-263T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013263_02
Start Time: 2013-263T00:00 Stop Time: 2013-264T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013264_02
Start Time: 2013-264T00:00 Stop Time: 2013-265T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013265_02
Start Time: 2013-265T00:00 Stop Time: 2013-266T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013266_02
Start Time: 2013-266T00:00 Stop Time: 2013-267T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013267_02
Start Time: 2013-267T00:00 Stop Time: 2013-268T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013268_02
Start Time: 2013-268T00:00 Stop Time: 2013-269T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013269_02
Start Time: 2013-269T00:00 Stop Time: 2013-270T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013270_02
Start Time: 2013-270T00:00 Stop Time: 2013-271T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013271_02
Start Time: 2013-271T00:00 Stop Time: 2013-272T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013272_02
Start Time: 2013-272T00:00 Stop Time: 2013-273T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013273_02
Start Time: 2013-273T00:00 Stop Time: 2013-274T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013274_02
Start Time: 2013-274T00:00 Stop Time: 2013-275T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013275_02
Start Time: 2013-275T00:00 Stop Time: 2013-276T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013276_02
Start Time: 2013-276T00:00 Stop Time: 2013-277T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013277_02
Start Time: 2013-277T00:00 Stop Time: 2013-278T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013278_02
Start Time: 2013-278T00:00 Stop Time: 2013-279T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013279_02
Start Time: 2013-279T00:00 Stop Time: 2013-280T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013280_02
Start Time: 2013-280T00:00 Stop Time: 2013-281T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013281_02
Start Time: 2013-281T00:00 Stop Time: 2013-282T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013282_02
Start Time: 2013-282T00:00 Stop Time: 2013-283T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013283_02
Start Time: 2013-283T00:00 Stop Time: 2013-284T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013284_02
Start Time: 2013-284T00:00 Stop Time: 2013-285T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013285_02
Start Time: 2013-285T00:00 Stop Time: 2013-286T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013286_02
Start Time: 2013-286T00:00 Stop Time: 2013-287T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013287_02
Start Time: 2013-287T00:00 Stop Time: 2013-288T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013288_02
Start Time: 2013-288T00:00 Stop Time: 2013-289T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013289_02
Start Time: 2013-289T00:00 Stop Time: 2013-290T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013290_02
Start Time: 2013-290T00:00 Stop Time: 2013-291T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013291_02
Start Time: 2013-291T00:00 Stop Time: 2013-292T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013292_02
Start Time: 2013-292T00:00 Stop Time: 2013-293T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013293_02
Start Time: 2013-293T00:00 Stop Time: 2013-294T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013294_02
Start Time: 2013-294T00:00 Stop Time: 2013-295T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013295_02
Start Time: 2013-295T00:00 Stop Time: 2013-296T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013296_02
Start Time: 2013-296T00:00 Stop Time: 2013-297T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013297_02
Start Time: 2013-297T00:00 Stop Time: 2013-298T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013298_02
Start Time: 2013-298T00:00 Stop Time: 2013-299T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013299_02
Start Time: 2013-299T00:00 Stop Time: 2013-300T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013300_02
Start Time: 2013-300T00:00 Stop Time: 2013-301T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013301_02
Start Time: 2013-301T00:00 Stop Time: 2013-302T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013302_02
Start Time: 2013-302T00:00 Stop Time: 2013-303T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013303_02
Start Time: 2013-303T00:00 Stop Time: 2013-304T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013304_02
Start Time: 2013-304T00:00 Stop Time: 2013-305T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013305_02
Start Time: 2013-305T00:00 Stop Time: 2013-306T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013306_02
Start Time: 2013-306T00:00 Stop Time: 2013-307T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013307_02
Start Time: 2013-307T00:00 Stop Time: 2013-308T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013308_02
Start Time: 2013-308T00:00 Stop Time: 2013-309T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013309_02
Start Time: 2013-309T00:00 Stop Time: 2013-310T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013310_02
Start Time: 2013-310T00:00 Stop Time: 2013-311T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013311_02
Start Time: 2013-311T00:00 Stop Time: 2013-312T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013312_02
Start Time: 2013-312T00:00 Stop Time: 2013-313T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013313_02
Start Time: 2013-313T00:00 Stop Time: 2013-314T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013314_02
Start Time: 2013-314T00:00 Stop Time: 2013-315T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013315_02
Start Time: 2013-315T00:00 Stop Time: 2013-316T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013316_02
Start Time: 2013-316T00:00 Stop Time: 2013-317T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013317_02
Start Time: 2013-317T00:00 Stop Time: 2013-318T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013318_02
Start Time: 2013-318T00:00 Stop Time: 2013-319T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013319_02
Start Time: 2013-319T00:00 Stop Time: 2013-320T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013320_02
Start Time: 2013-320T00:00 Stop Time: 2013-321T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013321_02
Start Time: 2013-321T00:00 Stop Time: 2013-322T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013322_02
Start Time: 2013-322T00:00 Stop Time: 2013-323T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013323_02
Start Time: 2013-323T00:00 Stop Time: 2013-324T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013324_02
Start Time: 2013-324T00:00 Stop Time: 2013-325T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013325_02
Start Time: 2013-325T00:00 Stop Time: 2013-326T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013326_02
Start Time: 2013-326T00:00 Stop Time: 2013-327T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013327_02
Start Time: 2013-327T00:00 Stop Time: 2013-328T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013328_02
Start Time: 2013-328T00:00 Stop Time: 2013-329T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013329_02
Start Time: 2013-329T00:00 Stop Time: 2013-330T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013330_02
Start Time: 2013-330T00:00 Stop Time: 2013-331T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013331_02
Start Time: 2013-331T00:00 Stop Time: 2013-332T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013332_02
Start Time: 2013-332T00:00 Stop Time: 2013-333T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013333_02
Start Time: 2013-333T00:00 Stop Time: 2013-334T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013334_02
Start Time: 2013-334T00:00 Stop Time: 2013-335T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013335_02
Start Time: 2013-335T00:00 Stop Time: 2013-336T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013336_02
Start Time: 2013-336T00:00 Stop Time: 2013-337T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013337_02
Start Time: 2013-337T00:00 Stop Time: 2013-338T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013338_02
Start Time: 2013-338T00:00 Stop Time: 2013-339T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013339_02
Start Time: 2013-339T00:00 Stop Time: 2013-340T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013340_02
Start Time: 2013-340T00:00 Stop Time: 2013-341T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013341_02
Start Time: 2013-341T00:00 Stop Time: 2013-342T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013342_02
Start Time: 2013-342T00:00 Stop Time: 2013-343T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013343_02
Start Time: 2013-343T00:00 Stop Time: 2013-344T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013344_02
Start Time: 2013-344T00:00 Stop Time: 2013-345T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013345_02
Start Time: 2013-345T00:00 Stop Time: 2013-346T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013346_02
Start Time: 2013-346T00:00 Stop Time: 2013-347T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013347_02
Start Time: 2013-347T00:00 Stop Time: 2013-348T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013348_02
Start Time: 2013-348T00:00 Stop Time: 2013-349T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013349_02
Start Time: 2013-349T00:00 Stop Time: 2013-350T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013350_02
Start Time: 2013-350T00:00 Stop Time: 2013-351T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013351_02
Start Time: 2013-351T00:00 Stop Time: 2013-352T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013352_02
Start Time: 2013-352T00:00 Stop Time: 2013-353T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013353_02
Start Time: 2013-353T00:00 Stop Time: 2013-354T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013354_02
Start Time: 2013-354T00:00 Stop Time: 2013-355T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013355_02
Start Time: 2013-355T00:00 Stop Time: 2013-356T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013356_02
Start Time: 2013-356T00:00 Stop Time: 2013-357T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013357_02
Start Time: 2013-357T00:00 Stop Time: 2013-358T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013358_02
Start Time: 2013-358T00:00 Stop Time: 2013-359T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013359_02
Start Time: 2013-359T00:00 Stop Time: 2013-360T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013360_02
Start Time: 2013-360T00:00 Stop Time: 2013-361T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013361_02
Start Time: 2013-361T00:00 Stop Time: 2013-362T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013362_02
Start Time: 2013-362T00:00 Stop Time: 2013-363T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013363_02
Start Time: 2013-363T00:00 Stop Time: 2013-364T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013364_02
Start Time: 2013-364T00:00 Stop Time: 2013-365T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2013365_02
Start Time: 2013-365T00:00 Stop Time: 2014-001T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench