• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Cassini >> MIMI
CASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE View Errata Order Volume Toggle viewing into brief mode
CO-S-MIMI-4-LEMMS-CALIB-V1.0 PDS 3      CERTIFIED
Start Time: 2004-01-01 08:00:00 - Stop Time: 2017-09-16 10:00:00
This contains calibrated Saturn tour data collected by the LEMMS sensor of the MIMI instrument aboard the Cassini spacecraft for the Cassini mission.
This contains calibrated Saturn tour data collected by the LEMMS sensor of the MIMI instrument aboard the Cassini spacecraft for the Cassini mission.    less ...
Citiation Information
Author Vandegriff J., Kusterer M.B.
TitleCASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE
PublisherNASA Planetary Data System
Publication Year 2018
doi https://doi.org/10.17189/1519608
Top/ DATA/ LPHAAVG0_1HR/ 2006 / click here to download folders and files
LPHAAVG0_1HR_2006001_01
Start Time: 2006-001T00:00 Stop Time: 2006-002T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006002_01
Start Time: 2006-002T00:00 Stop Time: 2006-003T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006003_01
Start Time: 2006-003T00:00 Stop Time: 2006-004T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006004_01
Start Time: 2006-004T00:00 Stop Time: 2006-005T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006005_01
Start Time: 2006-005T00:00 Stop Time: 2006-006T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006006_01
Start Time: 2006-006T00:00 Stop Time: 2006-007T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006007_01
Start Time: 2006-007T00:00 Stop Time: 2006-008T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006008_01
Start Time: 2006-008T00:00 Stop Time: 2006-009T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006009_01
Start Time: 2006-009T00:00 Stop Time: 2006-010T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006010_01
Start Time: 2006-010T00:00 Stop Time: 2006-011T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006011_01
Start Time: 2006-011T00:00 Stop Time: 2006-012T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006012_01
Start Time: 2006-012T00:00 Stop Time: 2006-013T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006013_01
Start Time: 2006-013T00:00 Stop Time: 2006-014T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006014_01
Start Time: 2006-014T00:00 Stop Time: 2006-015T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006015_01
Start Time: 2006-015T00:00 Stop Time: 2006-016T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006016_01
Start Time: 2006-016T00:00 Stop Time: 2006-017T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006017_01
Start Time: 2006-017T00:00 Stop Time: 2006-018T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006018_01
Start Time: 2006-018T00:00 Stop Time: 2006-019T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006019_01
Start Time: 2006-019T00:00 Stop Time: 2006-020T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006020_01
Start Time: 2006-020T00:00 Stop Time: 2006-021T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006021_01
Start Time: 2006-021T00:00 Stop Time: 2006-022T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006022_01
Start Time: 2006-022T00:00 Stop Time: 2006-023T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006023_01
Start Time: 2006-023T00:00 Stop Time: 2006-024T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006024_01
Start Time: 2006-024T00:00 Stop Time: 2006-025T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006025_01
Start Time: 2006-025T00:00 Stop Time: 2006-026T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006026_01
Start Time: 2006-026T00:00 Stop Time: 2006-027T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006027_01
Start Time: 2006-027T00:00 Stop Time: 2006-028T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006028_01
Start Time: 2006-028T00:00 Stop Time: 2006-029T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006029_01
Start Time: 2006-029T00:00 Stop Time: 2006-030T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006030_01
Start Time: 2006-030T00:00 Stop Time: 2006-031T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006031_01
Start Time: 2006-031T00:00 Stop Time: 2006-032T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006032_01
Start Time: 2006-032T00:00 Stop Time: 2006-033T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006033_01
Start Time: 2006-033T00:00 Stop Time: 2006-034T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006034_01
Start Time: 2006-034T00:00 Stop Time: 2006-035T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006035_01
Start Time: 2006-035T00:00 Stop Time: 2006-036T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006036_01
Start Time: 2006-036T00:00 Stop Time: 2006-037T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006037_01
Start Time: 2006-037T00:00 Stop Time: 2006-038T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006038_01
Start Time: 2006-038T00:00 Stop Time: 2006-039T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006039_01
Start Time: 2006-039T00:00 Stop Time: 2006-040T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006040_01
Start Time: 2006-040T00:00 Stop Time: 2006-041T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006041_01
Start Time: 2006-041T00:00 Stop Time: 2006-042T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006042_01
Start Time: 2006-042T00:00 Stop Time: 2006-043T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006043_01
Start Time: 2006-043T00:00 Stop Time: 2006-044T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006044_01
Start Time: 2006-044T00:00 Stop Time: 2006-045T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006045_01
Start Time: 2006-045T00:00 Stop Time: 2006-046T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006046_01
Start Time: 2006-046T00:00 Stop Time: 2006-047T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006047_01
Start Time: 2006-047T00:00 Stop Time: 2006-048T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006048_01
Start Time: 2006-048T00:00 Stop Time: 2006-049T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006049_01
Start Time: 2006-049T00:00 Stop Time: 2006-050T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006050_01
Start Time: 2006-050T00:00 Stop Time: 2006-051T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006051_01
Start Time: 2006-051T00:00 Stop Time: 2006-052T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006052_01
Start Time: 2006-052T00:00 Stop Time: 2006-053T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006053_01
Start Time: 2006-053T00:00 Stop Time: 2006-054T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006054_01
Start Time: 2006-054T00:00 Stop Time: 2006-055T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006055_01
Start Time: 2006-055T00:00 Stop Time: 2006-056T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006056_01
Start Time: 2006-056T00:00 Stop Time: 2006-057T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006057_01
Start Time: 2006-057T00:00 Stop Time: 2006-058T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006058_01
Start Time: 2006-058T00:00 Stop Time: 2006-059T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006059_01
Start Time: 2006-059T00:00 Stop Time: 2006-060T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006060_01
Start Time: 2006-060T00:00 Stop Time: 2006-061T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006061_01
Start Time: 2006-061T00:00 Stop Time: 2006-062T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006062_01
Start Time: 2006-062T00:00 Stop Time: 2006-063T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006063_01
Start Time: 2006-063T00:00 Stop Time: 2006-064T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006064_01
Start Time: 2006-064T00:00 Stop Time: 2006-065T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006065_01
Start Time: 2006-065T00:00 Stop Time: 2006-066T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006066_01
Start Time: 2006-066T00:00 Stop Time: 2006-067T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006067_01
Start Time: 2006-067T00:00 Stop Time: 2006-068T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006068_01
Start Time: 2006-068T00:00 Stop Time: 2006-069T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006069_01
Start Time: 2006-069T00:00 Stop Time: 2006-070T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006070_01
Start Time: 2006-070T00:00 Stop Time: 2006-071T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006071_01
Start Time: 2006-071T00:00 Stop Time: 2006-072T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006072_01
Start Time: 2006-072T00:00 Stop Time: 2006-073T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006073_01
Start Time: 2006-073T00:00 Stop Time: 2006-074T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006074_01
Start Time: 2006-074T00:00 Stop Time: 2006-075T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006075_01
Start Time: 2006-075T00:00 Stop Time: 2006-076T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006076_01
Start Time: 2006-076T00:00 Stop Time: 2006-077T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006077_01
Start Time: 2006-077T00:00 Stop Time: 2006-078T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006078_01
Start Time: 2006-078T00:00 Stop Time: 2006-079T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006079_01
Start Time: 2006-079T00:00 Stop Time: 2006-080T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006080_01
Start Time: 2006-080T00:00 Stop Time: 2006-081T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006081_01
Start Time: 2006-081T00:00 Stop Time: 2006-082T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006082_01
Start Time: 2006-082T00:00 Stop Time: 2006-083T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006083_01
Start Time: 2006-083T00:00 Stop Time: 2006-084T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006084_01
Start Time: 2006-084T00:00 Stop Time: 2006-085T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006085_01
Start Time: 2006-085T00:00 Stop Time: 2006-086T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006086_01
Start Time: 2006-086T00:00 Stop Time: 2006-087T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006087_01
Start Time: 2006-087T00:00 Stop Time: 2006-088T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006088_01
Start Time: 2006-088T00:00 Stop Time: 2006-089T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006089_01
Start Time: 2006-089T00:00 Stop Time: 2006-090T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006090_01
Start Time: 2006-090T00:00 Stop Time: 2006-091T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006091_01
Start Time: 2006-091T00:00 Stop Time: 2006-092T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006092_01
Start Time: 2006-092T00:00 Stop Time: 2006-093T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006093_01
Start Time: 2006-093T00:00 Stop Time: 2006-094T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006094_01
Start Time: 2006-094T00:00 Stop Time: 2006-095T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006095_01
Start Time: 2006-095T00:00 Stop Time: 2006-096T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006096_01
Start Time: 2006-096T00:00 Stop Time: 2006-097T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006097_01
Start Time: 2006-097T00:00 Stop Time: 2006-098T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006098_01
Start Time: 2006-098T00:00 Stop Time: 2006-099T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006099_01
Start Time: 2006-099T00:00 Stop Time: 2006-100T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006100_01
Start Time: 2006-100T00:00 Stop Time: 2006-101T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006101_01
Start Time: 2006-101T00:00 Stop Time: 2006-102T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006102_01
Start Time: 2006-102T00:00 Stop Time: 2006-103T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006103_01
Start Time: 2006-103T00:00 Stop Time: 2006-104T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006104_01
Start Time: 2006-104T00:00 Stop Time: 2006-105T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006105_01
Start Time: 2006-105T00:00 Stop Time: 2006-106T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006106_01
Start Time: 2006-106T00:00 Stop Time: 2006-107T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006107_01
Start Time: 2006-107T00:00 Stop Time: 2006-108T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006108_01
Start Time: 2006-108T00:00 Stop Time: 2006-109T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006109_01
Start Time: 2006-109T00:00 Stop Time: 2006-110T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006110_01
Start Time: 2006-110T00:00 Stop Time: 2006-111T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006111_01
Start Time: 2006-111T00:00 Stop Time: 2006-112T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006112_01
Start Time: 2006-112T00:00 Stop Time: 2006-113T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006113_01
Start Time: 2006-113T00:00 Stop Time: 2006-114T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006114_01
Start Time: 2006-114T00:00 Stop Time: 2006-115T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006115_01
Start Time: 2006-115T00:00 Stop Time: 2006-116T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006116_01
Start Time: 2006-116T00:00 Stop Time: 2006-117T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006117_01
Start Time: 2006-117T00:00 Stop Time: 2006-118T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006118_01
Start Time: 2006-118T00:00 Stop Time: 2006-119T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006119_01
Start Time: 2006-119T00:00 Stop Time: 2006-120T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006120_01
Start Time: 2006-120T00:00 Stop Time: 2006-121T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006121_01
Start Time: 2006-121T00:00 Stop Time: 2006-122T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006122_01
Start Time: 2006-122T00:00 Stop Time: 2006-123T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006123_01
Start Time: 2006-123T00:00 Stop Time: 2006-124T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006124_01
Start Time: 2006-124T00:00 Stop Time: 2006-125T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006125_01
Start Time: 2006-125T00:00 Stop Time: 2006-126T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006126_01
Start Time: 2006-126T00:00 Stop Time: 2006-127T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006127_01
Start Time: 2006-127T00:00 Stop Time: 2006-128T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006128_01
Start Time: 2006-128T00:00 Stop Time: 2006-129T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006129_01
Start Time: 2006-129T00:00 Stop Time: 2006-130T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006130_01
Start Time: 2006-130T00:00 Stop Time: 2006-131T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006131_01
Start Time: 2006-131T00:00 Stop Time: 2006-132T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006132_01
Start Time: 2006-132T00:00 Stop Time: 2006-133T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006133_01
Start Time: 2006-133T00:00 Stop Time: 2006-134T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006134_01
Start Time: 2006-134T00:00 Stop Time: 2006-135T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006135_01
Start Time: 2006-135T00:00 Stop Time: 2006-136T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006136_01
Start Time: 2006-136T00:00 Stop Time: 2006-137T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006137_01
Start Time: 2006-137T00:00 Stop Time: 2006-138T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006138_01
Start Time: 2006-138T00:00 Stop Time: 2006-139T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006139_01
Start Time: 2006-139T00:00 Stop Time: 2006-140T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006140_01
Start Time: 2006-140T00:00 Stop Time: 2006-141T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006141_01
Start Time: 2006-141T00:00 Stop Time: 2006-142T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006142_01
Start Time: 2006-142T00:00 Stop Time: 2006-143T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006143_01
Start Time: 2006-143T00:00 Stop Time: 2006-144T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006144_01
Start Time: 2006-144T00:00 Stop Time: 2006-145T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006145_01
Start Time: 2006-145T00:00 Stop Time: 2006-146T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006146_01
Start Time: 2006-146T00:00 Stop Time: 2006-147T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006147_01
Start Time: 2006-147T00:00 Stop Time: 2006-148T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006148_01
Start Time: 2006-148T00:00 Stop Time: 2006-149T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006149_01
Start Time: 2006-149T00:00 Stop Time: 2006-150T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006150_01
Start Time: 2006-150T00:00 Stop Time: 2006-151T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006151_01
Start Time: 2006-151T00:00 Stop Time: 2006-152T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006152_01
Start Time: 2006-152T00:00 Stop Time: 2006-153T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006153_01
Start Time: 2006-153T00:00 Stop Time: 2006-154T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006154_01
Start Time: 2006-154T00:00 Stop Time: 2006-155T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006155_01
Start Time: 2006-155T00:00 Stop Time: 2006-156T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006156_01
Start Time: 2006-156T00:00 Stop Time: 2006-157T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006157_01
Start Time: 2006-157T00:00 Stop Time: 2006-158T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006158_01
Start Time: 2006-158T00:00 Stop Time: 2006-159T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006159_01
Start Time: 2006-159T00:00 Stop Time: 2006-160T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006161_01
Start Time: 2006-161T00:00 Stop Time: 2006-162T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006162_01
Start Time: 2006-162T00:00 Stop Time: 2006-163T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006163_01
Start Time: 2006-163T00:00 Stop Time: 2006-164T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006164_01
Start Time: 2006-164T00:00 Stop Time: 2006-165T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006165_01
Start Time: 2006-165T00:00 Stop Time: 2006-166T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006166_01
Start Time: 2006-166T00:00 Stop Time: 2006-167T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006167_01
Start Time: 2006-167T00:00 Stop Time: 2006-168T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006168_01
Start Time: 2006-168T00:00 Stop Time: 2006-169T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006169_01
Start Time: 2006-169T00:00 Stop Time: 2006-170T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006170_01
Start Time: 2006-170T00:00 Stop Time: 2006-171T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006171_01
Start Time: 2006-171T00:00 Stop Time: 2006-172T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006172_01
Start Time: 2006-172T00:00 Stop Time: 2006-173T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006173_01
Start Time: 2006-173T00:00 Stop Time: 2006-174T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006174_01
Start Time: 2006-174T00:00 Stop Time: 2006-175T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006175_01
Start Time: 2006-175T00:00 Stop Time: 2006-176T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006176_01
Start Time: 2006-176T00:00 Stop Time: 2006-177T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006177_01
Start Time: 2006-177T00:00 Stop Time: 2006-178T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006178_01
Start Time: 2006-178T00:00 Stop Time: 2006-179T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006179_01
Start Time: 2006-179T00:00 Stop Time: 2006-180T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006180_01
Start Time: 2006-180T00:00 Stop Time: 2006-181T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006181_01
Start Time: 2006-181T00:00 Stop Time: 2006-182T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006182_01
Start Time: 2006-182T00:00 Stop Time: 2006-183T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006183_01
Start Time: 2006-183T00:00 Stop Time: 2006-184T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006184_01
Start Time: 2006-184T00:00 Stop Time: 2006-185T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006185_01
Start Time: 2006-185T00:00 Stop Time: 2006-186T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006186_01
Start Time: 2006-186T00:00 Stop Time: 2006-187T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006187_01
Start Time: 2006-187T00:00 Stop Time: 2006-188T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006188_01
Start Time: 2006-188T00:00 Stop Time: 2006-189T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006189_01
Start Time: 2006-189T00:00 Stop Time: 2006-190T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006190_01
Start Time: 2006-190T00:00 Stop Time: 2006-191T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006191_01
Start Time: 2006-191T00:00 Stop Time: 2006-192T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006192_01
Start Time: 2006-192T00:00 Stop Time: 2006-193T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006193_01
Start Time: 2006-193T00:00 Stop Time: 2006-194T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006194_01
Start Time: 2006-194T00:00 Stop Time: 2006-195T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006195_01
Start Time: 2006-195T00:00 Stop Time: 2006-196T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006196_01
Start Time: 2006-196T00:00 Stop Time: 2006-197T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006197_01
Start Time: 2006-197T00:00 Stop Time: 2006-198T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006198_01
Start Time: 2006-198T00:00 Stop Time: 2006-199T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006199_01
Start Time: 2006-199T00:00 Stop Time: 2006-200T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006200_01
Start Time: 2006-200T00:00 Stop Time: 2006-201T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006201_01
Start Time: 2006-201T00:00 Stop Time: 2006-202T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006202_01
Start Time: 2006-202T00:00 Stop Time: 2006-203T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006203_01
Start Time: 2006-203T00:00 Stop Time: 2006-204T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006204_01
Start Time: 2006-204T00:00 Stop Time: 2006-205T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006205_01
Start Time: 2006-205T00:00 Stop Time: 2006-206T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006206_01
Start Time: 2006-206T00:00 Stop Time: 2006-207T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006207_01
Start Time: 2006-207T00:00 Stop Time: 2006-208T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006208_01
Start Time: 2006-208T00:00 Stop Time: 2006-209T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006209_01
Start Time: 2006-209T00:00 Stop Time: 2006-210T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006210_01
Start Time: 2006-210T00:00 Stop Time: 2006-211T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006211_01
Start Time: 2006-211T00:00 Stop Time: 2006-212T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006212_01
Start Time: 2006-212T00:00 Stop Time: 2006-213T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006213_01
Start Time: 2006-213T00:00 Stop Time: 2006-214T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006214_01
Start Time: 2006-214T00:00 Stop Time: 2006-215T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006215_01
Start Time: 2006-215T00:00 Stop Time: 2006-216T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006216_01
Start Time: 2006-216T00:00 Stop Time: 2006-217T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006217_01
Start Time: 2006-217T00:00 Stop Time: 2006-218T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006218_01
Start Time: 2006-218T00:00 Stop Time: 2006-219T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006219_01
Start Time: 2006-219T00:00 Stop Time: 2006-220T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006220_01
Start Time: 2006-220T00:00 Stop Time: 2006-221T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006221_01
Start Time: 2006-221T00:00 Stop Time: 2006-222T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006222_01
Start Time: 2006-222T00:00 Stop Time: 2006-223T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006223_01
Start Time: 2006-223T00:00 Stop Time: 2006-224T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006224_01
Start Time: 2006-224T00:00 Stop Time: 2006-225T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006225_01
Start Time: 2006-225T00:00 Stop Time: 2006-226T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006226_01
Start Time: 2006-226T00:00 Stop Time: 2006-227T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006227_01
Start Time: 2006-227T00:00 Stop Time: 2006-228T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006228_01
Start Time: 2006-228T00:00 Stop Time: 2006-229T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006229_01
Start Time: 2006-229T00:00 Stop Time: 2006-230T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006230_01
Start Time: 2006-230T00:00 Stop Time: 2006-231T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006231_01
Start Time: 2006-231T00:00 Stop Time: 2006-232T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006232_01
Start Time: 2006-232T00:00 Stop Time: 2006-233T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006233_01
Start Time: 2006-233T00:00 Stop Time: 2006-234T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006234_01
Start Time: 2006-234T00:00 Stop Time: 2006-235T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006235_01
Start Time: 2006-235T00:00 Stop Time: 2006-236T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006236_01
Start Time: 2006-236T00:00 Stop Time: 2006-237T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006237_01
Start Time: 2006-237T00:00 Stop Time: 2006-238T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006238_01
Start Time: 2006-238T00:00 Stop Time: 2006-239T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006239_01
Start Time: 2006-239T00:00 Stop Time: 2006-240T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006240_01
Start Time: 2006-240T00:00 Stop Time: 2006-241T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006241_01
Start Time: 2006-241T00:00 Stop Time: 2006-242T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006242_01
Start Time: 2006-242T00:00 Stop Time: 2006-243T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006243_01
Start Time: 2006-243T00:00 Stop Time: 2006-244T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006244_01
Start Time: 2006-244T00:00 Stop Time: 2006-245T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006245_01
Start Time: 2006-245T00:00 Stop Time: 2006-246T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006246_01
Start Time: 2006-246T00:00 Stop Time: 2006-247T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006247_01
Start Time: 2006-247T00:00 Stop Time: 2006-248T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006248_01
Start Time: 2006-248T00:00 Stop Time: 2006-249T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006249_01
Start Time: 2006-249T00:00 Stop Time: 2006-250T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006250_01
Start Time: 2006-250T00:00 Stop Time: 2006-251T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006251_01
Start Time: 2006-251T00:00 Stop Time: 2006-252T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006252_01
Start Time: 2006-252T00:00 Stop Time: 2006-253T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006253_01
Start Time: 2006-253T00:00 Stop Time: 2006-254T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006254_01
Start Time: 2006-254T00:00 Stop Time: 2006-255T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006255_01
Start Time: 2006-255T00:00 Stop Time: 2006-256T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006256_01
Start Time: 2006-256T00:00 Stop Time: 2006-257T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006257_01
Start Time: 2006-257T00:00 Stop Time: 2006-258T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006258_01
Start Time: 2006-258T00:00 Stop Time: 2006-259T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006259_01
Start Time: 2006-259T00:00 Stop Time: 2006-260T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006260_01
Start Time: 2006-260T00:00 Stop Time: 2006-261T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006261_01
Start Time: 2006-261T00:00 Stop Time: 2006-262T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006262_01
Start Time: 2006-262T00:00 Stop Time: 2006-263T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006263_01
Start Time: 2006-263T00:00 Stop Time: 2006-264T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006264_01
Start Time: 2006-264T00:00 Stop Time: 2006-265T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006265_01
Start Time: 2006-265T00:00 Stop Time: 2006-266T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006266_01
Start Time: 2006-266T00:00 Stop Time: 2006-267T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006267_01
Start Time: 2006-267T00:00 Stop Time: 2006-268T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006268_01
Start Time: 2006-268T00:00 Stop Time: 2006-269T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006269_01
Start Time: 2006-269T00:00 Stop Time: 2006-270T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006270_01
Start Time: 2006-270T00:00 Stop Time: 2006-271T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006271_01
Start Time: 2006-271T00:00 Stop Time: 2006-272T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006272_01
Start Time: 2006-272T00:00 Stop Time: 2006-273T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006273_01
Start Time: 2006-273T00:00 Stop Time: 2006-274T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006274_01
Start Time: 2006-274T00:00 Stop Time: 2006-275T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006275_01
Start Time: 2006-275T00:00 Stop Time: 2006-276T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006276_01
Start Time: 2006-276T00:00 Stop Time: 2006-277T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006277_01
Start Time: 2006-277T00:00 Stop Time: 2006-278T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006278_01
Start Time: 2006-278T00:00 Stop Time: 2006-279T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006279_01
Start Time: 2006-279T00:00 Stop Time: 2006-280T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006280_01
Start Time: 2006-280T00:00 Stop Time: 2006-281T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006281_01
Start Time: 2006-281T00:00 Stop Time: 2006-282T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006282_01
Start Time: 2006-282T00:00 Stop Time: 2006-283T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006283_01
Start Time: 2006-283T00:00 Stop Time: 2006-284T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006284_01
Start Time: 2006-284T00:00 Stop Time: 2006-285T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006285_01
Start Time: 2006-285T00:00 Stop Time: 2006-286T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006286_01
Start Time: 2006-286T00:00 Stop Time: 2006-287T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006287_01
Start Time: 2006-287T00:00 Stop Time: 2006-288T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006288_01
Start Time: 2006-288T00:00 Stop Time: 2006-289T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006289_01
Start Time: 2006-289T00:00 Stop Time: 2006-290T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006290_01
Start Time: 2006-290T00:00 Stop Time: 2006-291T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006291_01
Start Time: 2006-291T00:00 Stop Time: 2006-292T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006292_01
Start Time: 2006-292T00:00 Stop Time: 2006-293T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006293_01
Start Time: 2006-293T00:00 Stop Time: 2006-294T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006294_01
Start Time: 2006-294T00:00 Stop Time: 2006-295T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006295_01
Start Time: 2006-295T00:00 Stop Time: 2006-296T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006296_01
Start Time: 2006-296T00:00 Stop Time: 2006-297T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006297_01
Start Time: 2006-297T00:00 Stop Time: 2006-298T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006298_01
Start Time: 2006-298T00:00 Stop Time: 2006-299T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006299_01
Start Time: 2006-299T00:00 Stop Time: 2006-300T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006300_01
Start Time: 2006-300T00:00 Stop Time: 2006-301T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006301_01
Start Time: 2006-301T00:00 Stop Time: 2006-302T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006302_01
Start Time: 2006-302T00:00 Stop Time: 2006-303T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006303_01
Start Time: 2006-303T00:00 Stop Time: 2006-304T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006304_01
Start Time: 2006-304T00:00 Stop Time: 2006-305T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006305_01
Start Time: 2006-305T00:00 Stop Time: 2006-306T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006306_01
Start Time: 2006-306T00:00 Stop Time: 2006-307T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006307_01
Start Time: 2006-307T00:00 Stop Time: 2006-308T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006308_01
Start Time: 2006-308T00:00 Stop Time: 2006-309T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006309_01
Start Time: 2006-309T00:00 Stop Time: 2006-310T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006310_01
Start Time: 2006-310T00:00 Stop Time: 2006-311T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006311_01
Start Time: 2006-311T00:00 Stop Time: 2006-312T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006312_01
Start Time: 2006-312T00:00 Stop Time: 2006-313T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006313_01
Start Time: 2006-313T00:00 Stop Time: 2006-314T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006314_01
Start Time: 2006-314T00:00 Stop Time: 2006-315T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006315_01
Start Time: 2006-315T00:00 Stop Time: 2006-316T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006316_01
Start Time: 2006-316T00:00 Stop Time: 2006-317T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006317_01
Start Time: 2006-317T00:00 Stop Time: 2006-318T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006318_01
Start Time: 2006-318T00:00 Stop Time: 2006-319T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006319_01
Start Time: 2006-319T00:00 Stop Time: 2006-320T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006320_01
Start Time: 2006-320T00:00 Stop Time: 2006-321T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006321_01
Start Time: 2006-321T00:00 Stop Time: 2006-322T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006322_01
Start Time: 2006-322T00:00 Stop Time: 2006-323T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006323_01
Start Time: 2006-323T00:00 Stop Time: 2006-324T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006324_01
Start Time: 2006-324T00:00 Stop Time: 2006-325T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006325_01
Start Time: 2006-325T00:00 Stop Time: 2006-326T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006326_01
Start Time: 2006-326T00:00 Stop Time: 2006-327T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006327_01
Start Time: 2006-327T00:00 Stop Time: 2006-328T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006328_01
Start Time: 2006-328T00:00 Stop Time: 2006-329T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006329_01
Start Time: 2006-329T00:00 Stop Time: 2006-330T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006330_01
Start Time: 2006-330T00:00 Stop Time: 2006-331T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006331_01
Start Time: 2006-331T00:00 Stop Time: 2006-332T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006332_01
Start Time: 2006-332T00:00 Stop Time: 2006-333T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006333_01
Start Time: 2006-333T00:00 Stop Time: 2006-334T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006334_01
Start Time: 2006-334T00:00 Stop Time: 2006-335T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006335_01
Start Time: 2006-335T00:00 Stop Time: 2006-336T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006336_01
Start Time: 2006-336T00:00 Stop Time: 2006-337T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006337_01
Start Time: 2006-337T00:00 Stop Time: 2006-338T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006338_01
Start Time: 2006-338T00:00 Stop Time: 2006-339T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006339_01
Start Time: 2006-339T00:00 Stop Time: 2006-340T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006340_01
Start Time: 2006-340T00:00 Stop Time: 2006-341T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006341_01
Start Time: 2006-341T00:00 Stop Time: 2006-342T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006342_01
Start Time: 2006-342T00:00 Stop Time: 2006-343T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006343_01
Start Time: 2006-343T00:00 Stop Time: 2006-344T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006344_01
Start Time: 2006-344T00:00 Stop Time: 2006-345T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006345_01
Start Time: 2006-345T00:00 Stop Time: 2006-346T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006346_01
Start Time: 2006-346T00:00 Stop Time: 2006-347T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006347_01
Start Time: 2006-347T00:00 Stop Time: 2006-348T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006348_01
Start Time: 2006-348T00:00 Stop Time: 2006-349T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006349_01
Start Time: 2006-349T00:00 Stop Time: 2006-350T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006350_01
Start Time: 2006-350T00:00 Stop Time: 2006-351T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006351_01
Start Time: 2006-351T00:00 Stop Time: 2006-352T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006352_01
Start Time: 2006-352T00:00 Stop Time: 2006-353T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006353_01
Start Time: 2006-353T00:00 Stop Time: 2006-354T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006354_01
Start Time: 2006-354T00:00 Stop Time: 2006-355T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006355_01
Start Time: 2006-355T00:00 Stop Time: 2006-356T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006356_01
Start Time: 2006-356T00:00 Stop Time: 2006-357T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006357_01
Start Time: 2006-357T00:00 Stop Time: 2006-358T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006358_01
Start Time: 2006-358T00:00 Stop Time: 2006-359T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006359_01
Start Time: 2006-359T00:00 Stop Time: 2006-360T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006360_01
Start Time: 2006-360T00:00 Stop Time: 2006-361T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006361_01
Start Time: 2006-361T00:00 Stop Time: 2006-362T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006362_01
Start Time: 2006-362T00:00 Stop Time: 2006-363T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006363_01
Start Time: 2006-363T00:00 Stop Time: 2006-364T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006364_01
Start Time: 2006-364T00:00 Stop Time: 2006-365T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1HR_2006365_01
Start Time: 2006-365T00:00 Stop Time: 2007-001T00:00
The data columns contain 1 hour averages of
LEMMS PHA data. The data are averaged by first defining fixed one hour
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench