• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Cassini >> MIMI
CASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE View Errata Order Volume Toggle viewing into brief mode
CO-S-MIMI-4-LEMMS-CALIB-V1.0 PDS 3      CERTIFIED
Start Time: 2004-01-01 08:00:00 - Stop Time: 2017-09-16 10:00:00
This contains calibrated Saturn tour data collected by the LEMMS sensor of the MIMI instrument aboard the Cassini spacecraft for the Cassini mission.
This contains calibrated Saturn tour data collected by the LEMMS sensor of the MIMI instrument aboard the Cassini spacecraft for the Cassini mission.    less ...
Citiation Information
Author Vandegriff J., Kusterer M.B.
TitleCASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE
PublisherNASA Planetary Data System
Publication Year 2018
doi https://doi.org/10.17189/1519608
Top/ DATA/ LACCFULL0/ 2016 / click here to download folders and files
LACCFULL0_2016001_01
Start Time: 2016-001T00:00:00.832 Stop Time: 2016-001T23:59:57.031
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016002_01
Start Time: 2016-002T00:00:00.781 Stop Time: 2016-002T23:59:56.625
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016003_01
Start Time: 2016-003T00:00:04.672 Stop Time: 2016-003T23:59:54.929
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016004_01
Start Time: 2016-004T00:00:00.554 Stop Time: 2016-004T23:59:54.753
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016005_01
Start Time: 2016-005T00:00:00.378 Stop Time: 2016-005T23:59:55.203
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016006_01
Start Time: 2016-006T00:00:00.828 Stop Time: 2016-006T23:59:55.777
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016007_01
Start Time: 2016-007T00:00:01.402 Stop Time: 2016-007T23:59:55.226
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016008_01
Start Time: 2016-008T00:00:00.851 Stop Time: 2016-008T23:59:56.179
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016009_01
Start Time: 2016-009T00:00:01.800 Stop Time: 2016-009T23:59:56.628
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016010_01
Start Time: 2016-010T00:00:04.608 Stop Time: 2016-010T23:59:54.015
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016011_01
Start Time: 2016-011T00:00:02.011 Stop Time: 2016-011T23:59:56.948
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016012_01
Start Time: 2016-012T00:00:04.905 Stop Time: 2016-012T23:59:56.722
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016013_01
Start Time: 2016-013T00:00:02.347 Stop Time: 2016-013T23:59:57.171
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016014_01
Start Time: 2016-014T00:00:00.921 Stop Time: 2016-014T23:59:55.745
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016015_01
Start Time: 2016-015T00:00:01.370 Stop Time: 2016-015T23:59:57.694
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016016_01
Start Time: 2016-016T00:00:03.323 Stop Time: 2016-016T23:59:52.624
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016017_01
Start Time: 2016-017T00:00:00.604 Stop Time: 2016-017T23:59:57.467
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016018_01
Start Time: 2016-018T00:00:03.092 Stop Time: 2016-018T23:59:56.041
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016019_01
Start Time: 2016-019T00:00:01.670 Stop Time: 2016-019T23:59:56.491
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016020_01
Start Time: 2016-020T00:00:02.119 Stop Time: 2016-020T23:59:52.994
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016021_01
Start Time: 2016-021T00:00:00.940 Stop Time: 2016-021T21:27:45.446
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016022_01
Start Time: 2016-022T01:37:24.979 Stop Time: 2016-022T23:59:55.403
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016023_01
Start Time: 2016-023T00:00:03.399 Stop Time: 2016-023T23:59:58.161
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016024_01
Start Time: 2016-024T00:00:03.786 Stop Time: 2016-024T23:59:58.735
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016025_01
Start Time: 2016-025T00:00:04.360 Stop Time: 2016-025T01:33:42.699
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016026_01
Start Time: 2016-026T01:12:35.786 Stop Time: 2016-026T23:59:56.852
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016027_01
Start Time: 2016-027T00:00:04.821 Stop Time: 2016-027T23:59:55.001
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016028_01
Start Time: 2016-028T00:00:03.020 Stop Time: 2016-028T23:59:56.032
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016029_01
Start Time: 2016-029T00:00:01.657 Stop Time: 2016-029T23:59:57.606
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016030_01
Start Time: 2016-030T00:00:01.356 Stop Time: 2016-030T23:59:57.180
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016031_01
Start Time: 2016-031T00:00:02.805 Stop Time: 2016-031T23:59:55.754
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016032_01
Start Time: 2016-032T00:00:00.442 Stop Time: 2016-032T23:59:56.203
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016033_01
Start Time: 2016-033T00:00:01.828 Stop Time: 2016-033T23:59:55.528
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016034_01
Start Time: 2016-034T00:00:01.152 Stop Time: 2016-034T23:59:55.602
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016035_01
Start Time: 2016-035T00:00:01.227 Stop Time: 2016-035T19:31:20.521
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016036_01
Start Time: 2016-036T00:19:29.297 Stop Time: 2016-036T23:59:58.633
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016037_01
Start Time: 2016-037T00:00:06.707 Stop Time: 2016-037T23:59:54.949
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016038_01
Start Time: 2016-038T00:00:00.574 Stop Time: 2016-038T23:59:56.614
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016039_01
Start Time: 2016-039T00:00:04.313 Stop Time: 2016-039T23:59:57.745
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016040_01
Start Time: 2016-040T00:00:03.370 Stop Time: 2016-040T23:59:58.182
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016041_01
Start Time: 2016-041T00:00:03.807 Stop Time: 2016-041T23:59:58.618
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016042_01
Start Time: 2016-042T00:00:04.243 Stop Time: 2016-042T23:59:58.054
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016043_01
Start Time: 2016-043T00:00:03.679 Stop Time: 2016-043T23:59:58.491
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016044_01
Start Time: 2016-044T00:00:04.116 Stop Time: 2016-044T23:59:57.927
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016045_01
Start Time: 2016-045T00:00:03.552 Stop Time: 2016-045T23:59:58.363
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016046_01
Start Time: 2016-046T00:00:02.113 Stop Time: 2016-046T23:59:59.800
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016047_01
Start Time: 2016-047T00:00:03.550 Stop Time: 2016-047T23:59:59.299
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016048_01
Start Time: 2016-048T00:00:02.111 Stop Time: 2016-048T23:59:54.235
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016049_01
Start Time: 2016-049T00:00:02.204 Stop Time: 2016-049T23:59:54.113
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016050_01
Start Time: 2016-050T00:00:02.077 Stop Time: 2016-050T23:59:58.670
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016051_01
Start Time: 2016-051T00:00:04.295 Stop Time: 2016-051T23:59:57.356
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016052_01
Start Time: 2016-052T00:00:02.981 Stop Time: 2016-052T23:59:57.793
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016053_01
Start Time: 2016-053T00:00:03.418 Stop Time: 2016-053T23:59:57.858
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016054_01
Start Time: 2016-054T00:00:03.479 Stop Time: 2016-054T23:59:58.294
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016055_01
Start Time: 2016-055T00:00:03.915 Stop Time: 2016-055T23:59:57.477
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016056_01
Start Time: 2016-056T00:00:03.102 Stop Time: 2016-056T23:59:56.913
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016057_01
Start Time: 2016-057T00:00:02.538 Stop Time: 2016-057T23:59:57.224
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016058_01
Start Time: 2016-058T00:00:02.849 Stop Time: 2016-058T23:59:57.911
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016059_01
Start Time: 2016-059T00:00:03.536 Stop Time: 2016-059T23:59:54.472
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016060_01
Start Time: 2016-060T00:00:00.097 Stop Time: 2016-060T23:59:54.908
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016061_01
Start Time: 2016-061T00:00:00.533 Stop Time: 2016-061T23:59:59.970
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016062_01
Start Time: 2016-062T00:00:05.595 Stop Time: 2016-062T23:59:54.781
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016063_01
Start Time: 2016-063T00:00:00.406 Stop Time: 2016-063T23:59:59.842
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016064_01
Start Time: 2016-064T00:00:05.467 Stop Time: 2016-064T23:59:54.654
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016065_01
Start Time: 2016-065T00:00:00.279 Stop Time: 2016-065T23:59:58.465
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016066_01
Start Time: 2016-066T00:00:04.090 Stop Time: 2016-066T10:00:43.230
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016068_01
Start Time: 2016-068T12:00:50.684 Stop Time: 2016-068T23:59:58.774
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016069_01
Start Time: 2016-069T00:00:04.399 Stop Time: 2016-069T23:59:57.334
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016070_01
Start Time: 2016-070T00:00:01.084 Stop Time: 2016-070T23:59:57.020
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016071_01
Start Time: 2016-071T00:00:00.770 Stop Time: 2016-071T23:59:54.832
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016072_01
Start Time: 2016-072T00:00:01.394 Stop Time: 2016-072T23:59:59.147
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016073_01
Start Time: 2016-073T00:00:05.706 Stop Time: 2016-073T23:59:54.454
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016074_01
Start Time: 2016-074T00:00:02.423 Stop Time: 2016-074T23:59:52.578
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016075_01
Start Time: 2016-075T00:00:00.547 Stop Time: 2016-075T23:59:54.456
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016076_01
Start Time: 2016-076T00:00:02.421 Stop Time: 2016-076T23:59:59.545
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016077_01
Start Time: 2016-077T00:00:07.513 Stop Time: 2016-077T23:59:52.856
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016078_01
Start Time: 2016-078T00:00:00.329 Stop Time: 2016-078T23:59:57.449
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016079_01
Start Time: 2016-079T00:00:05.417 Stop Time: 2016-079T23:59:55.572
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016080_01
Start Time: 2016-080T00:00:01.197 Stop Time: 2016-080T23:59:56.009
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016081_01
Start Time: 2016-081T00:00:01.634 Stop Time: 2016-081T23:59:55.789
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016082_01
Start Time: 2016-082T00:00:03.757 Stop Time: 2016-082T23:59:53.413
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016083_01
Start Time: 2016-083T00:00:01.381 Stop Time: 2016-083T23:59:58.724
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016084_01
Start Time: 2016-084T00:00:06.692 Stop Time: 2016-084T23:59:57.129
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016085_01
Start Time: 2016-085T00:00:05.098 Stop Time: 2016-085T23:59:52.409
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016086_01
Start Time: 2016-086T00:00:00.378 Stop Time: 2016-086T23:59:56.126
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016087_01
Start Time: 2016-087T00:00:01.751 Stop Time: 2016-087T23:59:56.563
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016088_01
Start Time: 2016-088T00:00:02.188 Stop Time: 2016-088T23:59:59.499
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016089_01
Start Time: 2016-089T00:00:05.124 Stop Time: 2016-089T23:59:54.810
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016090_01
Start Time: 2016-090T00:00:00.435 Stop Time: 2016-090T23:59:57.715
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016091_01
Start Time: 2016-091T00:00:05.684 Stop Time: 2016-091T23:59:56.683
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016092_01
Start Time: 2016-092T00:00:02.308 Stop Time: 2016-092T23:59:57.119
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016093_01
Start Time: 2016-093T00:00:02.744 Stop Time: 2016-093T23:59:57.556
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016094_01
Start Time: 2016-094T00:00:03.181 Stop Time: 2016-094T23:59:57.992
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016095_01
Start Time: 2016-095T00:00:03.617 Stop Time: 2016-095T23:59:54.678
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016096_01
Start Time: 2016-096T00:00:00.303 Stop Time: 2016-096T23:59:59.740
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016097_01
Start Time: 2016-097T00:00:05.364 Stop Time: 2016-097T23:59:56.426
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016098_01
Start Time: 2016-098T00:00:02.055 Stop Time: 2016-098T23:59:54.987
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016099_01
Start Time: 2016-099T00:00:00.612 Stop Time: 2016-099T23:59:55.423
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016100_01
Start Time: 2016-100T00:00:01.048 Stop Time: 2016-100T23:59:55.860
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016101_01
Start Time: 2016-101T00:00:01.485 Stop Time: 2016-101T23:59:56.046
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016102_01
Start Time: 2016-102T00:00:01.671 Stop Time: 2016-102T23:59:56.482
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016103_01
Start Time: 2016-103T00:00:02.107 Stop Time: 2016-103T23:59:55.294
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016104_01
Start Time: 2016-104T00:00:00.919 Stop Time: 2016-104T23:59:55.730
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016105_01
Start Time: 2016-105T00:00:01.355 Stop Time: 2016-105T23:59:59.291
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016106_01
Start Time: 2016-106T00:00:04.916 Stop Time: 2016-106T23:59:58.728
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016107_01
Start Time: 2016-107T00:00:04.353 Stop Time: 2016-107T23:59:57.789
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016108_01
Start Time: 2016-108T00:00:03.414 Stop Time: 2016-108T23:59:57.225
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016109_01
Start Time: 2016-109T00:00:02.850 Stop Time: 2016-109T23:59:53.876
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016110_01
Start Time: 2016-110T00:00:01.845 Stop Time: 2016-110T23:59:58.323
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016111_01
Start Time: 2016-111T00:00:03.948 Stop Time: 2016-111T23:59:57.644
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016112_01
Start Time: 2016-112T00:00:03.269 Stop Time: 2016-112T23:59:57.716
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016113_01
Start Time: 2016-113T00:00:03.341 Stop Time: 2016-113T23:59:59.662
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016114_01
Start Time: 2016-114T00:00:07.631 Stop Time: 2016-114T23:59:58.608
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016115_01
Start Time: 2016-115T00:00:04.233 Stop Time: 2016-115T23:59:59.055
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016116_01
Start Time: 2016-116T00:00:04.680 Stop Time: 2016-116T23:59:59.501
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016117_01
Start Time: 2016-117T00:00:05.126 Stop Time: 2016-117T23:59:58.948
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016118_01
Start Time: 2016-118T00:00:04.573 Stop Time: 2016-118T23:59:59.394
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016119_01
Start Time: 2016-119T00:00:05.019 Stop Time: 2016-119T23:59:58.841
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016120_01
Start Time: 2016-120T00:00:04.466 Stop Time: 2016-120T23:59:59.288
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016121_01
Start Time: 2016-121T00:00:04.913 Stop Time: 2016-121T23:59:59.734
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016122_01
Start Time: 2016-122T00:00:05.359 Stop Time: 2016-122T23:59:54.556
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016123_01
Start Time: 2016-123T00:00:00.181 Stop Time: 2016-123T23:59:59.627
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016124_01
Start Time: 2016-124T00:00:05.252 Stop Time: 2016-124T23:59:54.449
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016125_01
Start Time: 2016-125T00:00:00.074 Stop Time: 2016-125T23:59:57.395
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016126_01
Start Time: 2016-126T00:00:01.145 Stop Time: 2016-126T23:59:57.342
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016127_01
Start Time: 2016-127T00:00:02.967 Stop Time: 2016-127T23:59:57.788
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016128_01
Start Time: 2016-128T00:00:03.413 Stop Time: 2016-128T23:59:57.610
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016129_01
Start Time: 2016-129T00:00:03.235 Stop Time: 2016-129T23:59:55.306
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016130_01
Start Time: 2016-130T00:00:00.931 Stop Time: 2016-130T23:59:55.752
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016131_01
Start Time: 2016-131T00:00:01.377 Stop Time: 2016-131T23:59:54.699
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016132_01
Start Time: 2016-132T00:00:00.324 Stop Time: 2016-132T23:59:59.770
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016133_01
Start Time: 2016-133T00:00:05.395 Stop Time: 2016-133T23:59:54.342
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016134_01
Start Time: 2016-134T00:23:59.961 Stop Time: 2016-134T23:59:53.788
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016135_01
Start Time: 2016-135T00:23:59.408 Stop Time: 2016-135T23:59:54.235
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016136_01
Start Time: 2016-136T00:23:59.854 Stop Time: 2016-136T23:59:53.681
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016137_01
Start Time: 2016-137T00:23:59.301 Stop Time: 2016-137T23:59:59.225
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016138_01
Start Time: 2016-138T00:00:07.178 Stop Time: 2016-138T23:59:54.289
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016139_01
Start Time: 2016-139T00:00:02.207 Stop Time: 2016-139T23:59:56.895
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016140_01
Start Time: 2016-140T00:00:02.520 Stop Time: 2016-140T23:59:57.342
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016141_01
Start Time: 2016-141T00:00:02.967 Stop Time: 2016-141T23:59:57.788
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016142_01
Start Time: 2016-142T00:00:03.413 Stop Time: 2016-142T23:59:57.235
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016143_01
Start Time: 2016-143T00:00:02.860 Stop Time: 2016-143T23:59:57.681
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016144_01
Start Time: 2016-144T00:00:03.306 Stop Time: 2016-144T01:58:54.760
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016150_01
Start Time: 2016-150T22:33:09.593 Stop Time: 2016-150T23:59:55.162
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016151_01
Start Time: 2016-151T00:00:03.220 Stop Time: 2016-151T23:59:53.838
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016152_01
Start Time: 2016-152T00:00:01.756 Stop Time: 2016-152T23:59:54.406
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016153_01
Start Time: 2016-153T00:00:02.402 Stop Time: 2016-153T23:59:56.270
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016154_01
Start Time: 2016-154T00:00:01.895 Stop Time: 2016-154T23:59:59.342
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016155_01
Start Time: 2016-155T00:00:04.967 Stop Time: 2016-155T23:59:55.792
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016156_01
Start Time: 2016-156T00:00:01.413 Stop Time: 2016-156T23:59:58.360
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016157_01
Start Time: 2016-157T00:00:03.985 Stop Time: 2016-157T23:59:56.931
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016158_01
Start Time: 2016-158T00:00:00.685 Stop Time: 2016-158T23:59:53.389
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016159_01
Start Time: 2016-159T00:00:01.475 Stop Time: 2016-159T23:59:56.074
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016160_01
Start Time: 2016-160T00:00:00.761 Stop Time: 2016-160T23:59:55.583
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016161_01
Start Time: 2016-161T00:00:00.270 Stop Time: 2016-161T23:59:56.342
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016162_01
Start Time: 2016-162T00:00:01.967 Stop Time: 2016-162T23:59:56.917
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016163_01
Start Time: 2016-163T00:00:02.538 Stop Time: 2016-163T23:59:58.860
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016164_01
Start Time: 2016-164T00:00:04.485 Stop Time: 2016-164T23:59:58.181
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016165_01
Start Time: 2016-165T00:00:03.806 Stop Time: 2016-165T23:59:58.627
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016166_01
Start Time: 2016-166T00:00:04.252 Stop Time: 2016-166T23:59:54.574
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016167_01
Start Time: 2016-167T00:00:00.199 Stop Time: 2016-167T23:59:55.020
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016168_01
Start Time: 2016-168T00:00:00.645 Stop Time: 2016-168T23:59:55.718
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016169_01
Start Time: 2016-169T00:00:01.343 Stop Time: 2016-169T23:59:56.164
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016170_01
Start Time: 2016-170T00:00:01.789 Stop Time: 2016-170T23:59:56.611
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016171_01
Start Time: 2016-171T00:00:02.236 Stop Time: 2016-171T23:59:56.057
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016172_01
Start Time: 2016-172T00:00:01.682 Stop Time: 2016-172T23:59:56.503
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016173_01
Start Time: 2016-173T00:00:02.128 Stop Time: 2016-173T23:59:55.950
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016174_01
Start Time: 2016-174T00:00:01.575 Stop Time: 2016-174T23:59:56.396
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016175_01
Start Time: 2016-175T00:00:02.021 Stop Time: 2016-175T23:59:56.843
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016176_01
Start Time: 2016-176T00:00:02.468 Stop Time: 2016-176T23:59:56.289
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016177_01
Start Time: 2016-177T00:00:01.914 Stop Time: 2016-177T23:59:56.736
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016178_01
Start Time: 2016-178T00:00:02.360 Stop Time: 2016-178T23:59:57.270
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016179_01
Start Time: 2016-179T00:00:02.895 Stop Time: 2016-179T23:59:55.093
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016180_01
Start Time: 2016-180T00:00:00.718 Stop Time: 2016-180T23:59:58.166
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016181_01
Start Time: 2016-181T00:00:03.791 Stop Time: 2016-181T23:59:51.872
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016182_01
Start Time: 2016-182T00:00:00.001 Stop Time: 2016-182T23:59:56.809
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016183_01
Start Time: 2016-183T00:00:04.793 Stop Time: 2016-183T23:59:59.886
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016184_01
Start Time: 2016-184T00:00:03.636 Stop Time: 2016-184T23:59:57.084
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016185_01
Start Time: 2016-185T00:00:02.709 Stop Time: 2016-185T23:59:57.533
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016186_01
Start Time: 2016-186T00:00:03.157 Stop Time: 2016-186T23:59:56.981
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016187_01
Start Time: 2016-187T00:00:02.606 Stop Time: 2016-187T23:59:57.804
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016188_01
Start Time: 2016-188T00:00:03.429 Stop Time: 2016-188T23:59:56.252
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016189_01
Start Time: 2016-189T00:00:01.877 Stop Time: 2016-189T23:59:56.325
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016190_01
Start Time: 2016-190T00:00:01.950 Stop Time: 2016-190T23:59:58.399
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016191_01
Start Time: 2016-191T00:00:04.024 Stop Time: 2016-191T23:59:58.847
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016192_01
Start Time: 2016-192T00:00:04.472 Stop Time: 2016-192T23:59:58.295
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016193_01
Start Time: 2016-193T00:00:03.920 Stop Time: 2016-193T23:59:58.743
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016194_01
Start Time: 2016-194T00:00:04.368 Stop Time: 2016-194T23:59:59.192
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016195_01
Start Time: 2016-195T00:00:04.816 Stop Time: 2016-195T23:59:58.640
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016196_01
Start Time: 2016-196T00:00:04.265 Stop Time: 2016-196T23:59:59.088
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016197_01
Start Time: 2016-197T00:00:04.713 Stop Time: 2016-197T23:59:59.536
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016198_01
Start Time: 2016-198T00:00:05.161 Stop Time: 2016-198T23:59:58.984
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016199_01
Start Time: 2016-199T00:00:04.609 Stop Time: 2016-199T23:59:59.558
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016200_01
Start Time: 2016-200T00:00:05.183 Stop Time: 2016-200T23:59:56.756
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016201_01
Start Time: 2016-201T00:00:02.381 Stop Time: 2016-201T23:59:55.118
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016202_01
Start Time: 2016-202T00:00:03.192 Stop Time: 2016-202T23:59:56.652
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016203_01
Start Time: 2016-203T00:00:02.277 Stop Time: 2016-203T23:59:59.101
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016204_01
Start Time: 2016-204T00:00:04.725 Stop Time: 2016-204T23:59:55.050
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016205_01
Start Time: 2016-205T00:00:00.675 Stop Time: 2016-205T23:59:57.873
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016206_01
Start Time: 2016-206T00:00:05.842 Stop Time: 2016-206T23:59:56.946
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016207_01
Start Time: 2016-207T00:00:02.571 Stop Time: 2016-207T23:59:57.394
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016208_01
Start Time: 2016-208T00:00:03.019 Stop Time: 2016-208T23:59:59.718
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016209_01
Start Time: 2016-209T00:00:05.343 Stop Time: 2016-209T23:59:55.416
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016210_01
Start Time: 2016-210T00:00:01.041 Stop Time: 2016-210T23:59:56.989
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016211_01
Start Time: 2016-211T00:00:02.614 Stop Time: 2016-211T23:59:56.312
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016212_01
Start Time: 2016-212T00:00:01.941 Stop Time: 2016-212T23:59:56.229
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016213_01
Start Time: 2016-213T00:00:04.292 Stop Time: 2016-213T23:59:56.334
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016214_01
Start Time: 2016-214T00:00:01.959 Stop Time: 2016-214T23:59:56.907
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016215_01
Start Time: 2016-215T00:00:02.532 Stop Time: 2016-215T23:59:58.480
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016216_01
Start Time: 2016-216T00:00:04.105 Stop Time: 2016-216T23:59:58.053
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016217_01
Start Time: 2016-217T00:00:03.678 Stop Time: 2016-217T23:59:58.002
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016218_01
Start Time: 2016-218T00:00:03.627 Stop Time: 2016-218T23:59:55.200
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016219_01
Start Time: 2016-219T00:00:00.825 Stop Time: 2016-219T23:59:55.523
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016220_01
Start Time: 2016-220T00:00:01.148 Stop Time: 2016-220T23:59:59.221
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016221_01
Start Time: 2016-221T00:00:02.971 Stop Time: 2016-221T23:59:58.295
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016222_01
Start Time: 2016-222T00:00:03.920 Stop Time: 2016-222T23:59:54.868
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016223_01
Start Time: 2016-223T00:00:00.493 Stop Time: 2016-223T23:59:55.320
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016224_01
Start Time: 2016-224T00:00:00.941 Stop Time: 2016-224T23:59:57.639
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016225_01
Start Time: 2016-225T00:00:03.264 Stop Time: 2016-225T23:59:57.088
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016226_01
Start Time: 2016-226T00:00:02.712 Stop Time: 2016-226T23:59:54.411
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016227_01
Start Time: 2016-227T00:00:00.036 Stop Time: 2016-227T23:59:57.984
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016228_01
Start Time: 2016-228T00:00:03.609 Stop Time: 2016-228T23:59:57.561
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016229_01
Start Time: 2016-229T00:00:03.182 Stop Time: 2016-229T23:59:59.505
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016230_01
Start Time: 2016-230T00:00:05.130 Stop Time: 2016-230T23:59:58.829
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016231_01
Start Time: 2016-231T00:00:04.458 Stop Time: 2016-231T23:59:57.277
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016232_01
Start Time: 2016-232T00:00:02.902 Stop Time: 2016-232T23:59:59.600
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016233_01
Start Time: 2016-233T00:00:03.350 Stop Time: 2016-233T23:59:56.298
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016234_01
Start Time: 2016-234T00:00:00.048 Stop Time: 2016-234T23:59:58.622
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016235_01
Start Time: 2016-235T00:00:04.250 Stop Time: 2016-235T23:59:58.070
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016236_01
Start Time: 2016-236T00:00:03.699 Stop Time: 2016-236T23:59:56.268
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016237_01
Start Time: 2016-237T00:00:01.893 Stop Time: 2016-237T23:59:56.716
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016238_01
Start Time: 2016-238T00:00:02.341 Stop Time: 2016-238T23:59:58.790
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016239_01
Start Time: 2016-239T00:00:04.414 Stop Time: 2016-239T23:59:58.238
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016240_01
Start Time: 2016-240T00:00:03.863 Stop Time: 2016-240T23:59:59.436
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016241_01
Start Time: 2016-241T00:00:05.061 Stop Time: 2016-241T23:59:59.884
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016242_01
Start Time: 2016-242T00:00:05.509 Stop Time: 2016-242T23:59:55.836
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016243_01
Start Time: 2016-243T00:00:01.457 Stop Time: 2016-243T23:59:56.285
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016244_01
Start Time: 2016-244T00:00:01.906 Stop Time: 2016-244T23:59:56.733
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016245_01
Start Time: 2016-245T00:00:00.479 Stop Time: 2016-245T23:59:57.927
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016246_01
Start Time: 2016-246T00:00:01.677 Stop Time: 2016-246T23:59:59.875
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016247_01
Start Time: 2016-247T00:00:03.629 Stop Time: 2016-247T23:59:58.449
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016248_01
Start Time: 2016-248T00:00:04.077 Stop Time: 2016-248T23:59:56.178
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016249_01
Start Time: 2016-249T00:00:04.147 Stop Time: 2016-249T09:51:12.827
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016250_01
Start Time: 2016-250T01:43:21.934 Stop Time: 2016-250T23:59:59.422
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016251_01
Start Time: 2016-251T00:00:07.387 Stop Time: 2016-251T23:59:56.554
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016252_01
Start Time: 2016-252T00:00:04.523 Stop Time: 2016-252T23:59:54.059
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016253_01
Start Time: 2016-253T00:00:02.028 Stop Time: 2016-253T23:59:59.163
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016254_01
Start Time: 2016-254T00:00:07.636 Stop Time: 2016-254T23:59:58.203
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016255_01
Start Time: 2016-255T00:00:03.828 Stop Time: 2016-255T23:59:58.400
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016256_01
Start Time: 2016-256T00:00:04.025 Stop Time: 2016-256T23:59:58.847
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016257_01
Start Time: 2016-257T00:00:04.472 Stop Time: 2016-257T23:59:59.294
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016258_01
Start Time: 2016-258T00:00:04.919 Stop Time: 2016-258T23:59:59.616
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016259_01
Start Time: 2016-259T00:00:03.366 Stop Time: 2016-259T23:59:58.188
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016260_01
Start Time: 2016-260T00:00:03.813 Stop Time: 2016-260T23:59:55.763
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016261_01
Start Time: 2016-261T00:00:01.385 Stop Time: 2016-261T23:59:58.956
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016262_01
Start Time: 2016-262T00:00:04.581 Stop Time: 2016-262T23:59:56.528
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016263_01
Start Time: 2016-263T00:00:02.153 Stop Time: 2016-263T23:59:55.104
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016264_01
Start Time: 2016-264T00:00:00.725 Stop Time: 2016-264T23:59:54.551
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016265_01
Start Time: 2016-265T00:00:00.172 Stop Time: 2016-265T23:59:58.119
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016266_01
Start Time: 2016-266T00:00:03.744 Stop Time: 2016-266T23:59:53.378
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016267_01
Start Time: 2016-267T00:00:01.347 Stop Time: 2016-267T23:59:58.481
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016268_01
Start Time: 2016-268T00:00:06.450 Stop Time: 2016-268T23:59:53.772
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016269_01
Start Time: 2016-269T00:00:00.338 Stop Time: 2016-269T23:59:52.437
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016270_01
Start Time: 2016-270T00:00:00.406 Stop Time: 2016-270T23:59:57.853
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016271_01
Start Time: 2016-271T00:00:03.478 Stop Time: 2016-271T23:59:58.300
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016272_01
Start Time: 2016-272T00:00:03.925 Stop Time: 2016-272T23:59:57.747
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016273_01
Start Time: 2016-273T00:00:03.372 Stop Time: 2016-273T23:59:59.193
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016274_01
Start Time: 2016-274T00:00:04.818 Stop Time: 2016-274T23:59:54.890
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016275_01
Start Time: 2016-275T00:00:00.515 Stop Time: 2016-275T23:59:55.466
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016276_01
Start Time: 2016-276T00:00:01.087 Stop Time: 2016-276T23:59:55.409
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016277_01
Start Time: 2016-277T00:00:01.034 Stop Time: 2016-277T23:59:55.856
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016278_01
Start Time: 2016-278T00:00:01.481 Stop Time: 2016-278T23:59:55.053
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016279_01
Start Time: 2016-279T00:00:00.678 Stop Time: 2016-279T23:59:57.125
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016280_01
Start Time: 2016-280T00:00:02.750 Stop Time: 2016-280T23:59:58.446
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016281_01
Start Time: 2016-281T00:00:02.196 Stop Time: 2016-281T23:59:59.893
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016282_01
Start Time: 2016-282T00:00:05.518 Stop Time: 2016-282T23:59:57.594
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016283_01
Start Time: 2016-283T00:00:03.215 Stop Time: 2016-283T23:59:59.041
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016284_01
Start Time: 2016-284T00:00:07.045 Stop Time: 2016-284T23:59:54.609
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016285_01
Start Time: 2016-285T00:00:00.234 Stop Time: 2016-285T23:59:56.306
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016286_01
Start Time: 2016-286T00:00:01.935 Stop Time: 2016-286T23:59:54.753
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016287_01
Start Time: 2016-287T00:00:01.315 Stop Time: 2016-287T23:59:59.074
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016288_01
Start Time: 2016-288T00:00:05.637 Stop Time: 2016-288T23:59:56.646
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016289_01
Start Time: 2016-289T00:00:03.209 Stop Time: 2016-289T23:59:57.824
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016290_01
Start Time: 2016-290T00:00:05.843 Stop Time: 2016-290T23:59:59.759
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016291_01
Start Time: 2016-291T00:00:07.727 Stop Time: 2016-291T23:59:56.424
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016292_01
Start Time: 2016-292T00:00:04.393 Stop Time: 2016-292T23:59:53.063
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016293_01
Start Time: 2016-293T00:00:01.027 Stop Time: 2016-293T23:59:59.162
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016294_01
Start Time: 2016-294T00:00:07.130 Stop Time: 2016-294T23:59:56.796
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016295_01
Start Time: 2016-295T00:00:04.765 Stop Time: 2016-295T23:59:53.930
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016296_01
Start Time: 2016-296T00:00:01.403 Stop Time: 2016-296T23:59:53.409
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016297_01
Start Time: 2016-297T00:00:01.377 Stop Time: 2016-297T23:59:58.594
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016298_01
Start Time: 2016-298T00:00:06.523 Stop Time: 2016-298T23:59:59.865
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016299_01
Start Time: 2016-299T00:00:07.888 Stop Time: 2016-299T23:59:58.812
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016300_01
Start Time: 2016-300T00:00:04.437 Stop Time: 2016-300T23:59:57.508
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016301_01
Start Time: 2016-301T00:00:03.133 Stop Time: 2016-301T23:59:56.955
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016302_01
Start Time: 2016-302T00:00:04.924 Stop Time: 2016-302T23:59:55.613
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016303_01
Start Time: 2016-303T00:00:03.633 Stop Time: 2016-303T23:59:55.537
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016304_01
Start Time: 2016-304T00:00:03.505 Stop Time: 2016-304T23:59:57.045
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016305_01
Start Time: 2016-305T00:00:02.670 Stop Time: 2016-305T23:59:55.367
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016306_01
Start Time: 2016-306T00:00:00.992 Stop Time: 2016-306T23:59:55.239
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016307_01
Start Time: 2016-307T00:00:03.235 Stop Time: 2016-307T23:59:57.386
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016308_01
Start Time: 2016-308T00:00:03.010 Stop Time: 2016-308T23:59:58.063
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016309_01
Start Time: 2016-309T00:00:06.043 Stop Time: 2016-309T23:59:58.904
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016310_01
Start Time: 2016-310T00:00:02.654 Stop Time: 2016-310T23:59:59.824
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016311_01
Start Time: 2016-311T00:00:07.753 Stop Time: 2016-311T23:59:57.298
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016312_01
Start Time: 2016-312T00:00:02.923 Stop Time: 2016-312T23:59:57.999
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016313_01
Start Time: 2016-313T00:00:03.620 Stop Time: 2016-313T23:59:58.817
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016314_01
Start Time: 2016-314T00:00:04.446 Stop Time: 2016-314T23:59:58.724
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016315_01
Start Time: 2016-315T00:00:06.705 Stop Time: 2016-315T23:59:52.878
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016316_01
Start Time: 2016-316T00:00:00.824 Stop Time: 2016-316T23:59:57.532
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016317_01
Start Time: 2016-317T00:00:01.282 Stop Time: 2016-317T23:59:53.370
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016318_01
Start Time: 2016-318T00:00:01.276 Stop Time: 2016-318T23:59:59.864
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016319_01
Start Time: 2016-319T00:00:02.680 Stop Time: 2016-319T23:59:57.033
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016320_01
Start Time: 2016-320T00:00:05.013 Stop Time: 2016-320T23:59:55.011
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016321_01
Start Time: 2016-321T00:00:03.046 Stop Time: 2016-321T23:59:58.356
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016322_01
Start Time: 2016-322T00:00:06.274 Stop Time: 2016-322T23:59:59.713
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016323_01
Start Time: 2016-323T00:00:05.338 Stop Time: 2016-323T23:59:59.160
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016324_01
Start Time: 2016-324T00:00:04.785 Stop Time: 2016-324T23:59:56.857
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016325_01
Start Time: 2016-325T00:00:00.607 Stop Time: 2016-325T23:59:57.304
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016326_01
Start Time: 2016-326T00:00:01.054 Stop Time: 2016-326T23:59:57.075
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016327_01
Start Time: 2016-327T00:00:05.032 Stop Time: 2016-327T23:59:57.702
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016328_01
Start Time: 2016-328T00:00:03.323 Stop Time: 2016-328T23:59:58.149
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016329_01
Start Time: 2016-329T00:00:03.770 Stop Time: 2016-329T23:59:57.595
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016330_01
Start Time: 2016-330T00:00:03.217 Stop Time: 2016-330T23:59:59.913
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016331_01
Start Time: 2016-331T00:00:05.538 Stop Time: 2016-331T23:59:54.735
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016332_01
Start Time: 2016-332T00:00:00.360 Stop Time: 2016-332T23:59:58.936
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016333_01
Start Time: 2016-333T00:00:06.877 Stop Time: 2016-333T23:59:56.223
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016334_01
Start Time: 2016-334T00:00:04.192 Stop Time: 2016-334T23:59:59.076
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016335_01
Start Time: 2016-335T00:00:02.826 Stop Time: 2016-335T23:59:53.226
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016336_01
Start Time: 2016-336T00:00:00.277 Stop Time: 2016-336T23:59:53.235
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016337_01
Start Time: 2016-337T00:00:01.310 Stop Time: 2016-337T23:59:58.917
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016338_01
Start Time: 2016-338T00:00:04.542 Stop Time: 2016-338T23:59:59.363
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016339_01
Start Time: 2016-339T00:00:04.988 Stop Time: 2016-339T23:59:52.709
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016340_01
Start Time: 2016-340T00:00:00.666 Stop Time: 2016-340T23:59:57.882
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016341_01
Start Time: 2016-341T00:00:03.511 Stop Time: 2016-341T23:59:54.579
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016342_01
Start Time: 2016-342T00:00:00.204 Stop Time: 2016-342T23:59:55.026
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016343_01
Start Time: 2016-343T00:00:00.651 Stop Time: 2016-343T23:59:54.473
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016344_01
Start Time: 2016-344T00:00:00.098 Stop Time: 2016-344T23:59:54.920
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016345_01
Start Time: 2016-345T00:00:00.545 Stop Time: 2016-345T23:59:53.343
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016346_01
Start Time: 2016-346T00:00:01.284 Stop Time: 2016-346T23:59:59.563
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016347_01
Start Time: 2016-347T00:00:05.192 Stop Time: 2016-347T23:59:54.385
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016348_01
Start Time: 2016-348T00:00:00.010 Stop Time: 2016-348T23:59:51.789
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016349_01
Start Time: 2016-349T00:00:00.086 Stop Time: 2016-349T23:59:56.279
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016350_01
Start Time: 2016-350T00:00:01.904 Stop Time: 2016-350T23:59:56.726
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016351_01
Start Time: 2016-351T00:00:02.351 Stop Time: 2016-351T23:59:56.172
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016352_01
Start Time: 2016-352T00:00:01.797 Stop Time: 2016-352T23:59:56.619
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016353_01
Start Time: 2016-353T00:00:02.244 Stop Time: 2016-353T23:59:55.191
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016354_01
Start Time: 2016-354T00:00:00.816 Stop Time: 2016-354T23:59:59.387
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016355_01
Start Time: 2016-355T00:00:05.012 Stop Time: 2016-355T23:59:59.834
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016356_01
Start Time: 2016-356T00:00:05.459 Stop Time: 2016-356T23:59:59.406
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016357_01
Start Time: 2016-357T00:00:05.031 Stop Time: 2016-357T23:59:58.853
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016358_01
Start Time: 2016-358T00:00:04.478 Stop Time: 2016-358T23:59:58.425
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016359_01
Start Time: 2016-359T00:00:04.050 Stop Time: 2016-359T23:59:57.872
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016360_01
Start Time: 2016-360T00:00:03.497 Stop Time: 2016-360T23:59:58.319
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016361_01
Start Time: 2016-361T00:00:03.006 Stop Time: 2016-361T23:59:57.891
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016362_01
Start Time: 2016-362T00:00:01.641 Stop Time: 2016-362T23:59:56.462
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016363_01
Start Time: 2016-363T00:00:02.087 Stop Time: 2016-363T23:59:56.909
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016364_01
Start Time: 2016-364T00:00:02.534 Stop Time: 2016-364T23:59:57.356
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016365_01
Start Time: 2016-365T00:00:02.981 Stop Time: 2016-365T23:59:57.803
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
LACCFULL0_2016366_01
Start Time: 2016-366T00:00:03.428 Stop Time: 2016-366T23:59:57.250
The data columns contain full time
resolution of LEMMS accumulator rates data. The fill value for data in
this file is -1.0E38. These data are background subtracted, and thus
occasionally there will be negative values when the count rate falls
below the background level. Also, the uncertainties are based on the
counting statistics, and thus because of the background subtraction,
the uncertainties can be larger than the data value. The background
levels change over time and each channel's background level as a
function of time in counts/sec is listed in the MIMI calibration file (
described in the MIMI Data User Guide, the SIS for this dataset, and
also in SIS for the uncalibrated MIMI data). The channels A0 through
A8 are measured by the low energy end of LEMMS (the Low Energy
Telescope, or LET), and for protons these channels have an energy
range of 27 to 4000 keV. The P1 through P9 channels capture protons as
measured by the LEMMS High Energy Telescope (HET) and have an energy
range of 1 to 60 MeV. Channels C0 through C7 measure electrons, and
have an energy of 20 to 900 keV. The E0 through E4 channels are also
electrons covering the 150 to 3000 keV range. Also included are the
active priority channels respective to the datas time interval, and
The MIMI instrument paper describes these channels, as does the MIMI
Data User Guide. Following the data are columns describing certain
geometric parameters such as the position of Cassini in the SZS and
SZO frames. Also included are the pitch angle of the LET and HET.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench