• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Mars Express >> ASPERA-3
VOLUME 2: MARS EXPRESS ASPERA3 RDR ELS DATA View Errata Order Volume Toggle viewing into brief mode
MEX-M-ASPERA3-3-RDR-ELS-EXT2-V1.0 PDS 3      CERTIFIED
Start Time: 2007-10-01 21:23:50
Extension 2 calibrated data from the Electron Spectrometer (ELS) instrument of the Analyzer of Space Plasmas and Energetic Atoms experiment, 3rd edition (ASPERA-3), aboard the Mars Express spacecraft. The ASPERA-3 Principal Investigator is Dr. Rickard Lundin, Swedish Institute of Space Physics (IRF), Kiruna, Sweden. The primary source for ASPERA-3 data     more ...
Extension 2 calibrated data from the Electron Spectrometer (ELS) instrument of the Analyzer of Space Plasmas and Energetic Atoms experiment, 3rd edition (ASPERA-3), aboard the Mars Express spacecraft. The ASPERA-3 Principal Investigator is Dr. Rickard Lundin, Swedish Institute of Space Physics (IRF), Kiruna, Sweden. The primary source for ASPERA-3 data is the ESA Planetary Science Archive (PSA).    less ...
Citiation Information
Lundin, R., S. Barabash, D. Winningham, R. Frahm, MARS EXPRESS ASPERA-3 CAL RDR ELECTRON SPECTROMTR EXT2 V1.0, MEX-M-ASPERA3-3-RDR-ELS-EXT2-V1.0, ESA Planetary Science Archive (PSA), NASA Planetary Data System (PDS), 2005
Top/ DATA/ 2009/ 152_181JUN / click here to download folders and files
ELSSCIH20091520217DNFS01
Start Time: 2009-152T02:17:08.647 Stop Time: 2009-152T03:22:41.288
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091520326DNFS01
Start Time: 2009-152T03:26:53.040 Stop Time: 2009-152T05:12:20.506
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091520935DNFS01
Start Time: 2009-152T09:35:38.014 Stop Time: 2009-152T12:06:06.559
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091521605DNFS01
Start Time: 2009-152T16:05:04.880 Stop Time: 2009-152T19:10:55.999
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091522258DNFS01
Start Time: 2009-152T22:58:41.005 Stop Time: 2009-153T01:53:16.527
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091530552DNFS01
Start Time: 2009-153T05:52:14.845 Stop Time: 2009-153T08:47:22.991
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091531310DNFS01
Start Time: 2009-153T13:10:23.886 Stop Time: 2009-153T15:40:52.460
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091531939DNFS01
Start Time: 2009-153T19:39:50.811 Stop Time: 2009-153T22:34:26.115
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091540233DNFS01
Start Time: 2009-154T02:33:56.562 Stop Time: 2009-154T03:38:35.864
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091540342DNFS01
Start Time: 2009-154T03:42:48.333 Stop Time: 2009-154T05:28:15.397
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091540951DNFS01
Start Time: 2009-154T09:51:27.885 Stop Time: 2009-154T12:21:56.646
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091541621DNFS01
Start Time: 2009-154T16:21:27.090 Stop Time: 2009-154T19:16:02.482
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091542315DNFS01
Start Time: 2009-154T23:15:32.893 Stop Time: 2009-155T02:09:35.721
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091550609DNFS01
Start Time: 2009-155T06:09:06.163 Stop Time: 2009-155T07:03:26.461
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091550707DNFS01
Start Time: 2009-155T07:07:38.774 Stop Time: 2009-155T08:26:18.515
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091551410DNFS01
Start Time: 2009-155T14:10:40.250 Stop Time: 2009-155T15:57:12.378
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091551956DNFS01
Start Time: 2009-155T19:56:42.702 Stop Time: 2009-155T22:50:45.534
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091560250DNFS01
Start Time: 2009-156T02:50:15.945 Stop Time: 2009-156T03:54:27.152
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091560358DNFS01
Start Time: 2009-156T03:58:39.372 Stop Time: 2009-156T05:44:39.343
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091561007DNFS01
Start Time: 2009-156T10:07:18.000 Stop Time: 2009-156T12:38:18.638
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091561637DNFS01
Start Time: 2009-156T16:37:48.991 Stop Time: 2009-156T19:31:51.914
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091562331DNFS01
Start Time: 2009-156T23:31:54.449 Stop Time: 2009-157T02:25:57.002
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091570625DNFS01
Start Time: 2009-157T06:25:27.325 Stop Time: 2009-157T07:29:16.751
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091570733DNFS01
Start Time: 2009-157T07:33:28.971 Stop Time: 2009-157T09:19:29.406
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091571342DNFS01
Start Time: 2009-157T13:42:04.894 Stop Time: 2009-157T16:13:37.253
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091572013DNFS01
Start Time: 2009-157T20:13:07.639 Stop Time: 2009-157T22:53:47.001
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091581220DNFS01
Start Time: 2009-158T12:20:36.577 Stop Time: 2009-158T12:32:45.768
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091582348DNFS01
Start Time: 2009-158T23:48:23.002 Stop Time: 2009-159T02:37:00.928
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091590654DNFS01
Start Time: 2009-159T06:54:48.378 Stop Time: 2009-159T07:45:08.726
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091590749DNFS01
Start Time: 2009-159T07:49:20.477 Stop Time: 2009-159T09:35:52.695
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091591357DNFS01
Start Time: 2009-159T13:57:58.894 Stop Time: 2009-159T16:29:31.907
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091592030DNFS01
Start Time: 2009-159T20:30:06.385 Stop Time: 2009-159T23:23:05.220
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091600323DNFS01
Start Time: 2009-160T03:23:39.727 Stop Time: 2009-160T06:17:10.997
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091601039DNFS01
Start Time: 2009-160T10:39:06.013 Stop Time: 2009-160T13:10:38.310
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091601711DNFS01
Start Time: 2009-160T17:11:12.814 Stop Time: 2009-160T20:04:43.300
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091610005DNFS01
Start Time: 2009-161T00:05:17.806 Stop Time: 2009-161T02:58:16.391
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091610658DNFS01
Start Time: 2009-161T06:58:50.901 Stop Time: 2009-161T08:00:54.760
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091610805DNFS01
Start Time: 2009-161T08:05:06.761 Stop Time: 2009-161T09:51:38.232
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091611413DNFS01
Start Time: 2009-161T14:13:46.066 Stop Time: 2009-161T16:45:51.017
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091612046DNFS01
Start Time: 2009-161T20:46:25.525 Stop Time: 2009-161T23:39:23.797
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091620340DNFS01
Start Time: 2009-162T03:40:30.368 Stop Time: 2009-162T04:42:07.886
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091620446DNFS01
Start Time: 2009-162T04:46:20.012 Stop Time: 2009-162T06:33:24.921
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091621054DNFS01
Start Time: 2009-162T10:54:50.895 Stop Time: 2009-162T13:26:56.343
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091621728DNFS01
Start Time: 2009-162T17:28:02.856 Stop Time: 2009-162T20:20:29.061
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091630021DNFS01
Start Time: 2009-163T00:21:35.567 Stop Time: 2009-163T03:14:34.371
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091630715DNFS01
Start Time: 2009-163T07:15:08.909 Stop Time: 2009-163T10:08:07.862
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091631409DNFS01
Start Time: 2009-163T14:09:14.402 Stop Time: 2009-163T15:10:28.794
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091631514DNFS01
Start Time: 2009-163T15:14:41.420 Stop Time: 2009-163T17:01:45.983
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091632123DNFS01
Start Time: 2009-163T21:23:18.002 Stop Time: 2009-163T23:55:55.392
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091640357DNFS01
Start Time: 2009-164T03:57:01.964 Stop Time: 2009-164T06:49:28.640
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091641110DNFS01
Start Time: 2009-164T11:10:40.886 Stop Time: 2009-164T13:43:18.397
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091641744DNFS01
Start Time: 2009-164T17:44:24.937 Stop Time: 2009-164T20:36:51.735
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091650037DNFS01
Start Time: 2009-165T00:37:58.303 Stop Time: 2009-165T03:30:25.104
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091650732DNFS01
Start Time: 2009-165T07:32:03.743 Stop Time: 2009-165T10:24:30.357
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091651425DNFS01
Start Time: 2009-165T14:25:36.953 Stop Time: 2009-165T15:26:24.126
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091651530DNFS01
Start Time: 2009-165T15:30:36.377 Stop Time: 2009-165T17:18:12.845
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091652139DNFS01
Start Time: 2009-165T21:39:12.877 Stop Time: 2009-166T00:11:49.579
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091660413DNFS01
Start Time: 2009-166T04:13:28.368 Stop Time: 2009-166T07:05:54.762
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091661107DNFS01
Start Time: 2009-166T11:07:01.272 Stop Time: 2009-166T13:59:27.917
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091661801DNFS01
Start Time: 2009-166T18:01:06.577 Stop Time: 2009-166T18:44:10.153
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091661848DNFS01
Start Time: 2009-166T18:48:22.717 Stop Time: 2009-166T20:53:08.661
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091671447DNFS01
Start Time: 2009-167T14:47:04.291 Stop Time: 2009-167T17:34:41.592
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091672136DNFS01
Start Time: 2009-167T21:36:20.188 Stop Time: 2009-168T00:28:14.803
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091680429DNFS01
Start Time: 2009-168T04:29:53.405 Stop Time: 2009-168T05:29:39.203
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091680533DNFS01
Start Time: 2009-168T05:33:51.361 Stop Time: 2009-168T07:22:00.140
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091681142DNFS01
Start Time: 2009-168T11:42:18.896 Stop Time: 2009-168T14:15:27.787
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091681817DNFS01
Start Time: 2009-168T18:17:38.453 Stop Time: 2009-168T21:09:32.408
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091690111DNFS01
Start Time: 2009-169T01:11:10.979 Stop Time: 2009-169T04:03:05.408
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091690805DNFS01
Start Time: 2009-169T08:05:16.075 Stop Time: 2009-169T08:46:26.400
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091690850DNFS01
Start Time: 2009-169T08:50:38.714 Stop Time: 2009-169T10:57:00.096
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091691517DNFS01
Start Time: 2009-169T15:17:12.882 Stop Time: 2009-169T17:50:53.897
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091692153DNFS01
Start Time: 2009-169T21:53:04.593 Stop Time: 2009-170T00:44:26.986
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091700446DNFS01
Start Time: 2009-170T04:46:37.682 Stop Time: 2009-170T07:37:59.827
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091701140DNFS01
Start Time: 2009-170T11:40:10.483 Stop Time: 2009-170T12:39:03.439
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091701243DNFS01
Start Time: 2009-170T12:43:15.877 Stop Time: 2009-170T14:31:56.006
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091701851DNFS01
Start Time: 2009-170T18:51:56.890 Stop Time: 2009-170T21:25:38.153
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091710127DNFS01
Start Time: 2009-171T01:27:48.881 Stop Time: 2009-171T04:19:11.496
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091710821DNFS01
Start Time: 2009-171T08:21:54.258 Stop Time: 2009-171T11:13:16.436
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091711515DNFS01
Start Time: 2009-171T15:15:27.135 Stop Time: 2009-171T18:06:49.216
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091712226DNFS01
Start Time: 2009-171T22:26:43.031 Stop Time: 2009-172T01:00:24.045
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091720503DNFS01
Start Time: 2009-172T05:03:06.835 Stop Time: 2009-172T07:54:29.576
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091721157DNFS01
Start Time: 2009-172T11:57:12.394 Stop Time: 2009-172T14:48:02.694
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091721850DNFS01
Start Time: 2009-172T18:50:45.485 Stop Time: 2009-172T21:42:08.127
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091730144DNFS01
Start Time: 2009-173T01:44:50.883 Stop Time: 2009-173T02:25:24.831
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091730229DNFS01
Start Time: 2009-173T02:29:37.426 Stop Time: 2009-173T04:35:27.027
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091730855DNFS01
Start Time: 2009-173T08:55:20.881 Stop Time: 2009-173T11:29:34.211
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091731532DNFS01
Start Time: 2009-173T15:32:17.031 Stop Time: 2009-173T18:23:07.114
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091732226DNFS01
Start Time: 2009-173T22:26:21.904 Stop Time: 2009-174T01:16:39.672
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091740519DNFS01
Start Time: 2009-174T05:19:54.497 Stop Time: 2009-174T08:10:45.049
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091741230DNFS01
Start Time: 2009-174T12:30:08.919 Stop Time: 2009-174T15:04:22.275
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091741907DNFS01
Start Time: 2009-174T19:07:37.128 Stop Time: 2009-174T21:58:27.489
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091750201DNFS01
Start Time: 2009-175T02:01:10.205 Stop Time: 2009-175T02:57:23.032
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091750301DNFS01
Start Time: 2009-175T03:01:35.345 Stop Time: 2009-175T04:51:52.628
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091750911DNFS01
Start Time: 2009-175T09:11:06.909 Stop Time: 2009-175T11:45:52.736
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091751548DNFS01
Start Time: 2009-175T15:48:35.557 Stop Time: 2009-175T18:39:26.455
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091752242DNFS01
Start Time: 2009-175T22:42:41.243 Stop Time: 2009-176T01:32:58.385
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091760536DNFS01
Start Time: 2009-176T05:36:13.208 Stop Time: 2009-176T06:33:05.566
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091760637DNFS01
Start Time: 2009-176T06:37:17.911 Stop Time: 2009-176T08:27:02.538
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091761245DNFS01
Start Time: 2009-176T12:45:58.025 Stop Time: 2009-176T15:20:44.008
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091761923DNFS01
Start Time: 2009-176T19:23:58.799 Stop Time: 2009-176T22:14:16.939
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091770218DNFS01
Start Time: 2009-177T02:18:03.856 Stop Time: 2009-177T05:07:49.496
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091770911DNFS01
Start Time: 2009-177T09:11:36.382 Stop Time: 2009-177T12:01:55.088
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091771620DNFS01
Start Time: 2009-177T16:20:31.895 Stop Time: 2009-177T18:55:17.067
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091772259DNFS01
Start Time: 2009-177T22:59:03.918 Stop Time: 2009-178T01:49:22.060
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091780553DNFS01
Start Time: 2009-178T05:53:08.939 Stop Time: 2009-178T08:42:54.458
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091781246DNFS01
Start Time: 2009-178T12:46:41.315 Stop Time: 2009-178T15:36:59.614
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091781955DNFS01
Start Time: 2009-178T19:55:22.912 Stop Time: 2009-178T22:30:40.679
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091790234DNFS01
Start Time: 2009-179T02:34:27.598 Stop Time: 2009-179T05:24:13.369
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091790928DNFS01
Start Time: 2009-179T09:28:00.194 Stop Time: 2009-179T10:11:39.894
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091791015DNFS01
Start Time: 2009-179T10:15:52.271 Stop Time: 2009-179T12:17:56.648
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091791636DNFS01
Start Time: 2009-179T16:36:27.020 Stop Time: 2009-179T19:23:00.131
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091792315DNFS01
Start Time: 2009-179T23:15:33.735 Stop Time: 2009-180T02:05:19.628
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091800609DNFS01
Start Time: 2009-180T06:09:06.545 Stop Time: 2009-180T08:59:24.537
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091801302DNFS01
Start Time: 2009-180T13:02:39.373 Stop Time: 2009-180T15:52:57.389
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091801956DNFS01
Start Time: 2009-180T19:56:12.117 Stop Time: 2009-180T20:52:04.573
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091802056DNFS01
Start Time: 2009-180T20:56:17.065 Stop Time: 2009-180T22:46:34.187
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091810304DNFS01
Start Time: 2009-181T03:04:55.036 Stop Time: 2009-181T05:40:44.489
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091810943DNFS01
Start Time: 2009-181T09:43:27.310 Stop Time: 2009-181T12:49:18.076
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091811637DNFS01
Start Time: 2009-181T16:37:03.050 Stop Time: 2009-181T19:28:24.850
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20091812330DNFS01
Start Time: 2009-181T23:30:35.574 Stop Time: 2009-182T00:26:56.433
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091520217DNFS01
Start Time: 2009-152T02:17:10.522 Stop Time: 2009-152T03:22:43.381
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091520326DNFS01
Start Time: 2009-152T03:26:22.665 Stop Time: 2009-152T05:12:22.599
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091520935DNFS01
Start Time: 2009-152T09:35:39.889 Stop Time: 2009-152T12:06:08.653
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091521605DNFS01
Start Time: 2009-152T16:05:06.755 Stop Time: 2009-152T19:10:58.093
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091522258DNFS01
Start Time: 2009-152T22:58:42.880 Stop Time: 2009-153T01:53:18.621
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091530552DNFS01
Start Time: 2009-153T05:52:16.720 Stop Time: 2009-153T08:47:25.085
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091531310DNFS01
Start Time: 2009-153T13:10:25.761 Stop Time: 2009-153T15:40:54.554
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091531939DNFS01
Start Time: 2009-153T19:39:52.686 Stop Time: 2009-153T22:34:28.209
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091540233DNFS01
Start Time: 2009-154T02:33:58.437 Stop Time: 2009-154T03:38:37.958
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091540342DNFS01
Start Time: 2009-154T03:42:17.958 Stop Time: 2009-154T05:28:17.490
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091540951DNFS01
Start Time: 2009-154T09:51:29.760 Stop Time: 2009-154T12:21:58.739
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091541621DNFS01
Start Time: 2009-154T16:21:28.965 Stop Time: 2009-154T19:16:04.576
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091542315DNFS01
Start Time: 2009-154T23:15:34.768 Stop Time: 2009-155T02:09:37.815
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091550609DNFS01
Start Time: 2009-155T06:09:08.038 Stop Time: 2009-155T07:03:28.555
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091550707DNFS01
Start Time: 2009-155T07:07:08.399 Stop Time: 2009-155T08:26:20.609
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091551410DNFS01
Start Time: 2009-155T14:10:42.125 Stop Time: 2009-155T15:57:14.472
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091551956DNFS01
Start Time: 2009-155T19:56:44.577 Stop Time: 2009-155T22:50:47.628
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091560250DNFS01
Start Time: 2009-156T02:50:17.820 Stop Time: 2009-156T03:54:29.246
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091560358DNFS01
Start Time: 2009-156T03:58:08.996 Stop Time: 2009-156T05:44:41.437
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091561007DNFS01
Start Time: 2009-156T10:07:19.875 Stop Time: 2009-156T12:38:20.732
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091561637DNFS01
Start Time: 2009-156T16:37:50.866 Stop Time: 2009-156T19:31:54.008
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091562331DNFS01
Start Time: 2009-156T23:31:56.324 Stop Time: 2009-157T02:25:59.096
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091570625DNFS01
Start Time: 2009-157T06:25:29.200 Stop Time: 2009-157T07:29:18.844
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091570732DNFS01
Start Time: 2009-157T07:32:58.627 Stop Time: 2009-157T09:19:31.499
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091571342DNFS01
Start Time: 2009-157T13:42:06.769 Stop Time: 2009-157T16:13:39.346
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091572013DNFS01
Start Time: 2009-157T20:13:09.514 Stop Time: 2009-157T22:53:49.094
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091581220DNFS01
Start Time: 2009-158T12:20:38.452 Stop Time: 2009-158T12:32:47.862
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091582348DNFS01
Start Time: 2009-158T23:48:24.877 Stop Time: 2009-159T02:37:03.022
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091590654DNFS01
Start Time: 2009-159T06:54:50.253 Stop Time: 2009-159T07:45:10.820
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091590748DNFS01
Start Time: 2009-159T07:48:50.133 Stop Time: 2009-159T09:35:54.789
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091591358DNFS01
Start Time: 2009-159T13:58:00.769 Stop Time: 2009-159T16:29:34.001
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091592030DNFS01
Start Time: 2009-159T20:30:08.260 Stop Time: 2009-159T23:23:07.314
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091600323DNFS01
Start Time: 2009-160T03:23:41.602 Stop Time: 2009-160T06:17:13.091
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091601039DNFS01
Start Time: 2009-160T10:39:07.888 Stop Time: 2009-160T13:10:40.403
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091601711DNFS01
Start Time: 2009-160T17:11:14.689 Stop Time: 2009-160T20:04:45.393
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091610005DNFS01
Start Time: 2009-161T00:05:19.681 Stop Time: 2009-161T02:58:18.485
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091610658DNFS01
Start Time: 2009-161T06:58:52.776 Stop Time: 2009-161T08:00:56.854
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091610804DNFS01
Start Time: 2009-161T08:04:36.136 Stop Time: 2009-161T09:51:40.326
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091611413DNFS01
Start Time: 2009-161T14:13:47.941 Stop Time: 2009-161T16:45:53.111
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091612046DNFS01
Start Time: 2009-161T20:46:27.400 Stop Time: 2009-161T23:39:25.891
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091620340DNFS01
Start Time: 2009-162T03:40:32.243 Stop Time: 2009-162T04:42:09.980
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091620445DNFS01
Start Time: 2009-162T04:45:49.637 Stop Time: 2009-162T06:33:27.015
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091621054DNFS01
Start Time: 2009-162T10:54:52.770 Stop Time: 2009-162T13:26:58.437
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091621728DNFS01
Start Time: 2009-162T17:28:04.731 Stop Time: 2009-162T20:20:31.155
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091630021DNFS01
Start Time: 2009-163T00:21:37.442 Stop Time: 2009-163T03:14:36.464
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091630715DNFS01
Start Time: 2009-163T07:15:10.784 Stop Time: 2009-163T10:08:09.955
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091631409DNFS01
Start Time: 2009-163T14:09:16.277 Stop Time: 2009-163T15:10:30.887
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091631514DNFS01
Start Time: 2009-163T15:14:11.045 Stop Time: 2009-163T17:01:48.076
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091632123DNFS01
Start Time: 2009-163T21:23:19.877 Stop Time: 2009-163T23:55:57.486
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091640357DNFS01
Start Time: 2009-164T03:57:03.839 Stop Time: 2009-164T06:49:30.734
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091641110DNFS01
Start Time: 2009-164T11:10:42.761 Stop Time: 2009-164T13:43:20.491
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091641744DNFS01
Start Time: 2009-164T17:44:26.812 Stop Time: 2009-164T20:36:53.829
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091650038DNFS01
Start Time: 2009-165T00:38:00.178 Stop Time: 2009-165T03:30:27.198
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091650732DNFS01
Start Time: 2009-165T07:32:05.618 Stop Time: 2009-165T10:24:32.451
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091651425DNFS01
Start Time: 2009-165T14:25:38.828 Stop Time: 2009-165T15:26:26.220
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091651530DNFS01
Start Time: 2009-165T15:30:06.033 Stop Time: 2009-165T17:18:14.939
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091652139DNFS01
Start Time: 2009-165T21:39:14.752 Stop Time: 2009-166T00:11:51.672
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091660413DNFS01
Start Time: 2009-166T04:13:30.243 Stop Time: 2009-166T07:05:56.855
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091661107DNFS01
Start Time: 2009-166T11:07:03.147 Stop Time: 2009-166T13:59:30.011
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091661801DNFS01
Start Time: 2009-166T18:01:08.452 Stop Time: 2009-166T18:44:12.247
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091661847DNFS01
Start Time: 2009-166T18:47:52.342 Stop Time: 2009-166T20:53:10.755
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091671447DNFS01
Start Time: 2009-167T14:47:06.166 Stop Time: 2009-167T17:34:43.686
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091672136DNFS01
Start Time: 2009-167T21:36:22.063 Stop Time: 2009-168T00:28:16.897
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091680429DNFS01
Start Time: 2009-168T04:29:55.280 Stop Time: 2009-168T05:29:41.297
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091680533DNFS01
Start Time: 2009-168T05:33:20.985 Stop Time: 2009-168T07:22:02.234
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091681142DNFS01
Start Time: 2009-168T11:42:20.771 Stop Time: 2009-168T14:15:29.881
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091681817DNFS01
Start Time: 2009-168T18:17:40.328 Stop Time: 2009-168T21:09:34.501
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091690111DNFS01
Start Time: 2009-169T01:11:12.854 Stop Time: 2009-169T04:03:07.501
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091690805DNFS01
Start Time: 2009-169T08:05:17.950 Stop Time: 2009-169T08:46:28.493
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091690850DNFS01
Start Time: 2009-169T08:50:08.370 Stop Time: 2009-169T10:57:02.190
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091691517DNFS01
Start Time: 2009-169T15:17:14.757 Stop Time: 2009-169T17:50:55.991
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091692153DNFS01
Start Time: 2009-169T21:53:06.468 Stop Time: 2009-170T00:44:29.080
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091700446DNFS01
Start Time: 2009-170T04:46:39.557 Stop Time: 2009-170T07:38:01.921
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091701140DNFS01
Start Time: 2009-170T11:40:12.358 Stop Time: 2009-170T12:39:05.533
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091701242DNFS01
Start Time: 2009-170T12:42:45.502 Stop Time: 2009-170T14:31:58.100
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091701851DNFS01
Start Time: 2009-170T18:51:58.765 Stop Time: 2009-170T21:25:40.247
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091710127DNFS01
Start Time: 2009-171T01:27:50.756 Stop Time: 2009-171T04:19:13.590
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091710821DNFS01
Start Time: 2009-171T08:21:56.133 Stop Time: 2009-171T11:13:18.530
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091711515DNFS01
Start Time: 2009-171T15:15:29.010 Stop Time: 2009-171T18:06:51.309
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091712226DNFS01
Start Time: 2009-171T22:26:44.906 Stop Time: 2009-172T01:00:26.138
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091720503DNFS01
Start Time: 2009-172T05:03:08.710 Stop Time: 2009-172T07:54:31.670
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091721157DNFS01
Start Time: 2009-172T11:57:14.269 Stop Time: 2009-172T14:48:04.788
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091721850DNFS01
Start Time: 2009-172T18:50:47.360 Stop Time: 2009-172T21:42:10.221
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091730144DNFS01
Start Time: 2009-173T01:44:52.758 Stop Time: 2009-173T02:25:26.925
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091730229DNFS01
Start Time: 2009-173T02:29:07.050 Stop Time: 2009-173T04:35:29.121
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091730855DNFS01
Start Time: 2009-173T08:55:22.756 Stop Time: 2009-173T11:29:36.305
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091731532DNFS01
Start Time: 2009-173T15:32:18.906 Stop Time: 2009-173T18:23:09.208
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091732226DNFS01
Start Time: 2009-173T22:26:23.779 Stop Time: 2009-174T01:16:41.766
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091740519DNFS01
Start Time: 2009-174T05:19:56.372 Stop Time: 2009-174T08:10:47.142
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091741230DNFS01
Start Time: 2009-174T12:30:10.794 Stop Time: 2009-174T15:04:24.368
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091741907DNFS01
Start Time: 2009-174T19:07:39.003 Stop Time: 2009-174T21:58:29.582
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091750201DNFS01
Start Time: 2009-175T02:01:12.080 Stop Time: 2009-175T02:57:25.126
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091750301DNFS01
Start Time: 2009-175T03:01:04.970 Stop Time: 2009-175T04:51:54.722
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091750911DNFS01
Start Time: 2009-175T09:11:08.784 Stop Time: 2009-175T11:45:54.830
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091751548DNFS01
Start Time: 2009-175T15:48:37.432 Stop Time: 2009-175T18:39:28.549
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091752242DNFS01
Start Time: 2009-175T22:42:43.118 Stop Time: 2009-176T01:33:00.479
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091760536DNFS01
Start Time: 2009-176T05:36:15.083 Stop Time: 2009-176T06:33:07.660
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091760636DNFS01
Start Time: 2009-176T06:36:47.536 Stop Time: 2009-176T08:27:04.632
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091761245DNFS01
Start Time: 2009-176T12:45:59.900 Stop Time: 2009-176T15:20:46.102
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091761924DNFS01
Start Time: 2009-176T19:24:00.674 Stop Time: 2009-176T22:14:19.033
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091770218DNFS01
Start Time: 2009-177T02:18:05.731 Stop Time: 2009-177T05:07:51.589
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091770911DNFS01
Start Time: 2009-177T09:11:38.257 Stop Time: 2009-177T12:01:57.181
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091771620DNFS01
Start Time: 2009-177T16:20:33.770 Stop Time: 2009-177T18:55:19.160
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091772259DNFS01
Start Time: 2009-177T22:59:05.793 Stop Time: 2009-178T01:49:24.154
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091780553DNFS01
Start Time: 2009-178T05:53:10.814 Stop Time: 2009-178T08:42:56.552
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091781246DNFS01
Start Time: 2009-178T12:46:43.190 Stop Time: 2009-178T15:37:01.708
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091781955DNFS01
Start Time: 2009-178T19:55:24.787 Stop Time: 2009-178T22:30:42.773
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091790234DNFS01
Start Time: 2009-179T02:34:29.473 Stop Time: 2009-179T05:24:15.463
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091790928DNFS01
Start Time: 2009-179T09:28:02.069 Stop Time: 2009-179T10:11:41.988
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091791015DNFS01
Start Time: 2009-179T10:15:21.895 Stop Time: 2009-179T12:17:58.742
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091791636DNFS01
Start Time: 2009-179T16:36:28.895 Stop Time: 2009-179T19:23:02.225
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091792315DNFS01
Start Time: 2009-179T23:15:35.610 Stop Time: 2009-180T02:05:21.721
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091800609DNFS01
Start Time: 2009-180T06:09:08.420 Stop Time: 2009-180T08:59:26.631
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091801302DNFS01
Start Time: 2009-180T13:02:41.248 Stop Time: 2009-180T15:52:59.483
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091801956DNFS01
Start Time: 2009-180T19:56:13.992 Stop Time: 2009-180T20:52:06.667
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091802055DNFS01
Start Time: 2009-180T20:55:46.690 Stop Time: 2009-180T22:46:36.281
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091810304DNFS01
Start Time: 2009-181T03:04:56.911 Stop Time: 2009-181T05:40:46.583
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091810943DNFS01
Start Time: 2009-181T09:43:29.185 Stop Time: 2009-181T12:49:20.170
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091811637DNFS01
Start Time: 2009-181T16:37:04.925 Stop Time: 2009-181T19:28:26.944
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20091812330DNFS01
Start Time: 2009-181T23:30:37.449 Stop Time: 2009-182T00:26:58.527
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench