• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Mars Express >> ASPERA-3
VOLUME 2: MARS EXPRESS ASPERA3 RDR ELS DATA View Errata Order Volume Toggle viewing into brief mode
MEX-M-ASPERA3-3-RDR-ELS-EXT2-V1.0 PDS 3      CERTIFIED
Start Time: 2007-10-01 21:23:50
Extension 2 calibrated data from the Electron Spectrometer (ELS) instrument of the Analyzer of Space Plasmas and Energetic Atoms experiment, 3rd edition (ASPERA-3), aboard the Mars Express spacecraft. The ASPERA-3 Principal Investigator is Dr. Rickard Lundin, Swedish Institute of Space Physics (IRF), Kiruna, Sweden. The primary source for ASPERA-3 data     more ...
Extension 2 calibrated data from the Electron Spectrometer (ELS) instrument of the Analyzer of Space Plasmas and Energetic Atoms experiment, 3rd edition (ASPERA-3), aboard the Mars Express spacecraft. The ASPERA-3 Principal Investigator is Dr. Rickard Lundin, Swedish Institute of Space Physics (IRF), Kiruna, Sweden. The primary source for ASPERA-3 data is the ESA Planetary Science Archive (PSA).    less ...
Citiation Information
Lundin, R., S. Barabash, D. Winningham, R. Frahm, MARS EXPRESS ASPERA-3 CAL RDR ELECTRON SPECTROMTR EXT2 V1.0, MEX-M-ASPERA3-3-RDR-ELS-EXT2-V1.0, ESA Planetary Science Archive (PSA), NASA Planetary Data System (PDS), 2005
Top/ DATA/ 2009/ 060_090MAR / click here to download folders and files
ELSSCIH20090611238DNFS01
Start Time: 2009-061T12:38:22.901 Stop Time: 2009-061T17:16:56.108
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090611932DNFS01
Start Time: 2009-061T19:32:14.275 Stop Time: 2009-062T00:10:47.326
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090650618DNFS01
Start Time: 2009-065T06:18:46.231 Stop Time: 2009-065T10:54:38.713
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090651312DNFS01
Start Time: 2009-065T13:12:37.191 Stop Time: 2009-065T17:48:29.424
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090652005DNFS01
Start Time: 2009-065T20:05:55.840 Stop Time: 2009-065T23:07:26.452
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090652311DNFS01
Start Time: 2009-065T23:11:39.579 Stop Time: 2009-066T00:42:06.886
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090660510DNFS01
Start Time: 2009-066T05:10:46.921 Stop Time: 2009-066T07:35:53.994
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090660954DNFS01
Start Time: 2009-066T09:54:24.533 Stop Time: 2009-066T14:29:12.712
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090661647DNFS01
Start Time: 2009-066T16:47:43.254 Stop Time: 2009-066T20:14:11.410
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090662109DNFS01
Start Time: 2009-066T21:09:45.270 Stop Time: 2009-066T21:23:02.711
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090670635DNFS01
Start Time: 2009-067T06:35:09.785 Stop Time: 2009-067T11:10:30.862
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090671539DNFS01
Start Time: 2009-067T15:39:02.910 Stop Time: 2009-067T18:04:09.951
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090672023DNFS01
Start Time: 2009-067T20:23:44.620 Stop Time: 2009-067T21:27:56.294
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090680318DNFS01
Start Time: 2009-068T03:18:38.485 Stop Time: 2009-068T06:16:53.848
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090680621DNFS01
Start Time: 2009-068T06:21:06.444 Stop Time: 2009-068T07:43:31.623
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090681728DNFS01
Start Time: 2009-068T17:28:53.694 Stop Time: 2009-068T21:39:02.609
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090690023DNFS01
Start Time: 2009-069T00:23:12.157 Stop Time: 2009-069T04:32:16.543
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090690716DNFS01
Start Time: 2009-069T07:16:58.125 Stop Time: 2009-069T09:53:01.106
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090690957DNFS01
Start Time: 2009-069T09:57:13.483 Stop Time: 2009-069T11:26:04.164
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090691554DNFS01
Start Time: 2009-069T15:54:49.100 Stop Time: 2009-069T18:19:56.516
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090692104DNFS01
Start Time: 2009-069T21:04:38.097 Stop Time: 2009-070T01:13:42.765
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090700358DNFS01
Start Time: 2009-070T03:58:56.436 Stop Time: 2009-070T08:06:56.796
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090701052DNFS01
Start Time: 2009-070T10:52:42.498 Stop Time: 2009-070T13:28:18.605
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090701332DNFS01
Start Time: 2009-070T13:32:30.575 Stop Time: 2009-070T15:00:50.067
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090701929DNFS01
Start Time: 2009-070T19:29:30.915 Stop Time: 2009-070T21:54:37.954
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090710040DNFS01
Start Time: 2009-071T00:40:23.661 Stop Time: 2009-071T03:07:39.423
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090710417DNFS01
Start Time: 2009-071T04:17:57.631 Stop Time: 2009-071T04:47:51.734
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090710734DNFS01
Start Time: 2009-071T07:34:41.564 Stop Time: 2009-071T08:05:07.979
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090711113DNFS01
Start Time: 2009-071T11:13:51.725 Stop Time: 2009-071T11:41:37.390
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090711428DNFS01
Start Time: 2009-071T14:28:27.222 Stop Time: 2009-071T17:03:40.645
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090711707DNFS01
Start Time: 2009-071T17:07:52.739 Stop Time: 2009-071T18:35:39.077
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090712304DNFS01
Start Time: 2009-071T23:04:10.905 Stop Time: 2009-072T01:29:17.980
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090720416DNFS01
Start Time: 2009-072T04:16:07.842 Stop Time: 2009-072T08:23:04.852
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090721109DNFS01
Start Time: 2009-072T11:09:54.744 Stop Time: 2009-072T15:16:18.349
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090721804DNFS01
Start Time: 2009-072T18:04:12.299 Stop Time: 2009-072T22:10:03.869
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090730238DNFS01
Start Time: 2009-073T02:38:49.047 Stop Time: 2009-073T05:03:56.089
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090730751DNFS01
Start Time: 2009-073T07:51:50.074 Stop Time: 2009-073T09:45:52.049
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090731026DNFS01
Start Time: 2009-073T10:26:25.592 Stop Time: 2009-073T11:57:41.369
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090731446DNFS01
Start Time: 2009-073T14:46:07.413 Stop Time: 2009-073T17:20:27.677
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090731724DNFS01
Start Time: 2009-073T17:24:40.053 Stop Time: 2009-073T18:51:22.362
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090732319DNFS01
Start Time: 2009-073T23:19:54.913 Stop Time: 2009-074T00:01:16.612
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090740624DNFS01
Start Time: 2009-074T06:24:55.605 Stop Time: 2009-074T08:38:15.927
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090741127DNFS01
Start Time: 2009-074T11:27:46.100 Stop Time: 2009-074T12:01:25.297
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090741446DNFS01
Start Time: 2009-074T14:46:34.504 Stop Time: 2009-074T15:32:01.394
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090741821DNFS01
Start Time: 2009-074T18:21:31.567 Stop Time: 2009-074T20:55:44.863
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090742059DNFS01
Start Time: 2009-074T20:59:56.489 Stop Time: 2009-074T22:25:34.263
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090750254DNFS01
Start Time: 2009-075T02:54:33.050 Stop Time: 2009-075T05:19:40.188
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090750809DNFS01
Start Time: 2009-075T08:09:42.454 Stop Time: 2009-075T12:13:25.557
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090751503DNFS01
Start Time: 2009-075T15:03:27.826 Stop Time: 2009-075T19:06:39.336
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090752157DNFS01
Start Time: 2009-075T21:57:13.606 Stop Time: 2009-076T02:00:24.681
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090760450DNFS01
Start Time: 2009-076T04:50:58.916 Stop Time: 2009-076T07:24:52.495
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090760729DNFS01
Start Time: 2009-076T07:29:05.152 Stop Time: 2009-076T08:54:10.865
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090761322DNFS01
Start Time: 2009-076T13:22:57.929 Stop Time: 2009-076T15:48:04.938
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090761839DNFS01
Start Time: 2009-076T18:39:11.270 Stop Time: 2009-076T22:41:49.620
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090770132DNFS01
Start Time: 2009-077T01:32:55.950 Stop Time: 2009-077T05:35:03.057
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090770827DNFS01
Start Time: 2009-077T08:27:13.514 Stop Time: 2009-077T11:00:16.780
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090771104DNFS01
Start Time: 2009-077T11:04:29.500 Stop Time: 2009-077T12:29:03.400
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090771657DNFS01
Start Time: 2009-077T16:57:38.926 Stop Time: 2009-077T19:22:46.000
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090772214DNFS01
Start Time: 2009-077T22:14:56.491 Stop Time: 2009-078T02:16:30.814
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090780508DNFS01
Start Time: 2009-078T05:08:41.270 Stop Time: 2009-078T09:09:43.467
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090781202DNFS01
Start Time: 2009-078T12:02:58.017 Stop Time: 2009-078T14:35:36.998
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090781439DNFS01
Start Time: 2009-078T14:39:49.499 Stop Time: 2009-078T16:03:50.992
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090782032DNFS01
Start Time: 2009-078T20:32:22.976 Stop Time: 2009-078T22:57:29.740
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090790150DNFS01
Start Time: 2009-079T01:50:44.319 Stop Time: 2009-079T05:51:14.422
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090790844DNFS01
Start Time: 2009-079T08:44:29.003 Stop Time: 2009-079T12:44:26.853
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090791538DNFS01
Start Time: 2009-079T15:38:45.560 Stop Time: 2009-079T18:10:51.979
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090791815DNFS01
Start Time: 2009-079T18:15:04.511 Stop Time: 2009-079T19:38:33.756
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090800007DNFS01
Start Time: 2009-080T00:07:01.939 Stop Time: 2009-080T02:32:08.760
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090800526DNFS01
Start Time: 2009-080T05:26:27.468 Stop Time: 2009-080T09:25:53.066
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090801220DNFS01
Start Time: 2009-080T12:20:11.774 Stop Time: 2009-080T16:19:36.748
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090801914DNFS01
Start Time: 2009-080T19:14:27.547 Stop Time: 2009-080T23:12:48.615
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090810208DNFS01
Start Time: 2009-081T02:08:11.506 Stop Time: 2009-081T02:24:09.761
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090810259DNFS01
Start Time: 2009-081T02:59:06.054 Stop Time: 2009-081T06:06:32.762
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090811035DNFS01
Start Time: 2009-081T10:35:21.035 Stop Time: 2009-081T13:00:27.798
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090811555DNFS01
Start Time: 2009-081T15:55:50.630 Stop Time: 2009-081T19:54:11.981
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090812250DNFS01
Start Time: 2009-081T22:50:06.910 Stop Time: 2009-082T02:47:23.722
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090820543DNFS01
Start Time: 2009-082T05:43:50.680 Stop Time: 2009-082T08:15:14.534
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090820819DNFS01
Start Time: 2009-082T08:19:26.628 Stop Time: 2009-082T09:41:19.401
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090821410DNFS01
Start Time: 2009-082T14:10:05.049 Stop Time: 2009-082T16:46:27.473
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090821931DNFS01
Start Time: 2009-082T19:31:41.150 Stop Time: 2009-082T23:28:58.284
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090830225DNFS01
Start Time: 2009-083T02:25:57.338 Stop Time: 2009-083T04:00:09.741
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090831146DNFS01
Start Time: 2009-083T11:46:46.616 Stop Time: 2009-083T13:16:09.956
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090831613DNFS01
Start Time: 2009-083T16:13:41.039 Stop Time: 2009-083T20:09:53.486
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090832307DNFS01
Start Time: 2009-083T23:07:24.570 Stop Time: 2009-084T03:03:36.858
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090840601DNFS01
Start Time: 2009-084T06:01:07.976 Stop Time: 2009-084T08:32:05.398
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090840836DNFS01
Start Time: 2009-084T08:36:17.523 Stop Time: 2009-084T09:57:06.233
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090841425DNFS01
Start Time: 2009-084T14:25:46.916 Stop Time: 2009-084T16:50:53.928
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090841949DNFS01
Start Time: 2009-084T19:49:29.139 Stop Time: 2009-084T23:44:37.273
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090850243DNFS01
Start Time: 2009-085T02:43:12.514 Stop Time: 2009-085T06:38:20.867
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090850936DNFS01
Start Time: 2009-085T09:36:56.105 Stop Time: 2009-085T11:06:19.384
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090851143DNFS01
Start Time: 2009-085T11:43:24.486 Stop Time: 2009-085T13:31:32.924
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090851800DNFS01
Start Time: 2009-085T18:00:26.898 Stop Time: 2009-085T20:25:34.192
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090852325DNFS01
Start Time: 2009-085T23:25:13.496 Stop Time: 2009-086T03:19:17.755
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090860618DNFS01
Start Time: 2009-086T06:18:57.122 Stop Time: 2009-086T10:13:00.850
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090861312DNFS01
Start Time: 2009-086T13:12:40.185 Stop Time: 2009-086T15:42:46.540
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090861546DNFS01
Start Time: 2009-086T15:46:58.510 Stop Time: 2009-086T17:06:10.814
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090862135DNFS01
Start Time: 2009-086T21:35:05.901 Stop Time: 2009-087T00:00:13.000
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090870300DNFS01
Start Time: 2009-087T03:00:56.494 Stop Time: 2009-087T06:53:56.314
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090870954DNFS01
Start Time: 2009-087T09:54:39.834 Stop Time: 2009-087T13:47:07.524
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090871816DNFS01
Start Time: 2009-087T18:16:10.030 Stop Time: 2009-087T20:41:17.106
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090872342DNFS01
Start Time: 2009-087T23:42:32.664 Stop Time: 2009-088T03:35:00.945
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090880636DNFS01
Start Time: 2009-088T06:36:16.429 Stop Time: 2009-088T10:28:45.096
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090881330DNFS01
Start Time: 2009-088T13:30:32.709 Stop Time: 2009-088T17:21:55.933
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090882150DNFS01
Start Time: 2009-088T21:50:54.047 Stop Time: 2009-089T00:27:16.466
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090890318DNFS01
Start Time: 2009-089T03:18:22.860 Stop Time: 2009-089T07:09:46.706
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090891012DNFS01
Start Time: 2009-089T10:12:06.382 Stop Time: 2009-089T14:02:57.606
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090891706DNFS01
Start Time: 2009-089T17:06:21.411 Stop Time: 2009-089T20:56:41.011
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090900125DNFS01
Start Time: 2009-090T01:25:38.921 Stop Time: 2009-090T03:50:45.904
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090900654DNFS01
Start Time: 2009-090T06:54:09.709 Stop Time: 2009-090T10:44:29.587
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090901347DNFS01
Start Time: 2009-090T13:47:53.392 Stop Time: 2009-090T17:38:12.052
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090902042DNFS01
Start Time: 2009-090T20:42:07.885 Stop Time: 2009-091T00:31:22.233
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090611238DNFS01
Start Time: 2009-061T12:38:24.776 Stop Time: 2009-061T17:16:58.202
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090611932DNFS01
Start Time: 2009-061T19:32:16.150 Stop Time: 2009-062T00:10:49.420
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090650618DNFS01
Start Time: 2009-065T06:18:48.106 Stop Time: 2009-065T10:54:40.807
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090651312DNFS01
Start Time: 2009-065T13:12:39.066 Stop Time: 2009-065T17:48:31.518
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090652005DNFS01
Start Time: 2009-065T20:05:57.715 Stop Time: 2009-065T23:07:28.546
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090652311DNFS01
Start Time: 2009-065T23:11:09.203 Stop Time: 2009-066T00:42:08.980
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090660510DNFS01
Start Time: 2009-066T05:10:48.796 Stop Time: 2009-066T07:35:56.087
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090660954DNFS01
Start Time: 2009-066T09:54:26.408 Stop Time: 2009-066T14:29:14.805
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090661647DNFS01
Start Time: 2009-066T16:47:45.129 Stop Time: 2009-066T20:14:13.503
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090662109DNFS01
Start Time: 2009-066T21:09:47.145 Stop Time: 2009-066T21:23:04.804
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090670635DNFS01
Start Time: 2009-067T06:35:11.660 Stop Time: 2009-067T11:10:32.956
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090671539DNFS01
Start Time: 2009-067T15:39:04.785 Stop Time: 2009-067T18:04:12.045
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090672023DNFS01
Start Time: 2009-067T20:23:46.495 Stop Time: 2009-067T21:27:58.388
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090680318DNFS01
Start Time: 2009-068T03:18:40.360 Stop Time: 2009-068T06:16:55.942
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090680620DNFS01
Start Time: 2009-068T06:20:36.068 Stop Time: 2009-068T07:43:33.717
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090681728DNFS01
Start Time: 2009-068T17:28:55.569 Stop Time: 2009-068T21:39:04.703
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090690023DNFS01
Start Time: 2009-069T00:23:14.032 Stop Time: 2009-069T04:32:18.636
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090690717DNFS01
Start Time: 2009-069T07:17:00.000 Stop Time: 2009-069T09:53:03.199
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090690956DNFS01
Start Time: 2009-069T09:56:43.076 Stop Time: 2009-069T11:26:06.257
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090691554DNFS01
Start Time: 2009-069T15:54:50.975 Stop Time: 2009-069T18:19:58.609
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090692104DNFS01
Start Time: 2009-069T21:04:39.972 Stop Time: 2009-070T01:13:44.858
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090700358DNFS01
Start Time: 2009-070T03:58:58.311 Stop Time: 2009-070T08:06:58.889
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090701052DNFS01
Start Time: 2009-070T10:52:44.373 Stop Time: 2009-070T13:28:20.699
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090701332DNFS01
Start Time: 2009-070T13:32:00.231 Stop Time: 2009-070T15:00:52.161
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090701929DNFS01
Start Time: 2009-070T19:29:32.790 Stop Time: 2009-070T21:54:40.048
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090710040DNFS01
Start Time: 2009-071T00:40:25.536 Stop Time: 2009-071T03:07:41.517
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090710417DNFS01
Start Time: 2009-071T04:17:59.506 Stop Time: 2009-071T04:47:53.828
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090710734DNFS01
Start Time: 2009-071T07:34:43.439 Stop Time: 2009-071T08:05:10.073
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090711113DNFS01
Start Time: 2009-071T11:13:53.600 Stop Time: 2009-071T11:41:39.484
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090711428DNFS01
Start Time: 2009-071T14:28:29.097 Stop Time: 2009-071T17:03:42.739
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090711707DNFS01
Start Time: 2009-071T17:07:22.365 Stop Time: 2009-071T18:35:41.171
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090712304DNFS01
Start Time: 2009-071T23:04:12.780 Stop Time: 2009-072T01:29:20.074
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090720416DNFS01
Start Time: 2009-072T04:16:09.717 Stop Time: 2009-072T08:23:06.946
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090721109DNFS01
Start Time: 2009-072T11:09:56.619 Stop Time: 2009-072T15:16:20.443
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090721804DNFS01
Start Time: 2009-072T18:04:14.174 Stop Time: 2009-072T22:10:05.963
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090730238DNFS01
Start Time: 2009-073T02:38:50.922 Stop Time: 2009-073T05:03:58.183
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090730751DNFS01
Start Time: 2009-073T07:51:51.949 Stop Time: 2009-073T09:45:54.143
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090731026DNFS01
Start Time: 2009-073T10:26:27.467 Stop Time: 2009-073T11:57:43.463
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090731446DNFS01
Start Time: 2009-073T14:46:09.288 Stop Time: 2009-073T17:20:29.771
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090731724DNFS01
Start Time: 2009-073T17:24:09.677 Stop Time: 2009-073T18:51:24.456
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090732319DNFS01
Start Time: 2009-073T23:19:56.788 Stop Time: 2009-074T00:01:18.706
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090740624DNFS01
Start Time: 2009-074T06:24:57.480 Stop Time: 2009-074T08:38:18.020
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090741127DNFS01
Start Time: 2009-074T11:27:47.975 Stop Time: 2009-074T12:01:27.390
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090741446DNFS01
Start Time: 2009-074T14:46:36.379 Stop Time: 2009-074T15:32:03.487
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090741821DNFS01
Start Time: 2009-074T18:21:33.442 Stop Time: 2009-074T20:55:46.956
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090742059DNFS01
Start Time: 2009-074T20:59:26.114 Stop Time: 2009-074T22:25:36.356
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090750254DNFS01
Start Time: 2009-075T02:54:34.925 Stop Time: 2009-075T05:19:42.281
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090750809DNFS01
Start Time: 2009-075T08:09:44.329 Stop Time: 2009-075T12:13:27.650
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090751503DNFS01
Start Time: 2009-075T15:03:29.701 Stop Time: 2009-075T19:06:41.430
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090752157DNFS01
Start Time: 2009-075T21:57:15.481 Stop Time: 2009-076T02:00:26.775
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090760451DNFS01
Start Time: 2009-076T04:51:00.791 Stop Time: 2009-076T07:24:54.589
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090760728DNFS01
Start Time: 2009-076T07:28:34.746 Stop Time: 2009-076T08:54:12.959
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090761322DNFS01
Start Time: 2009-076T13:22:59.804 Stop Time: 2009-076T15:48:07.032
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090761839DNFS01
Start Time: 2009-076T18:39:13.145 Stop Time: 2009-076T22:41:51.714
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090770132DNFS01
Start Time: 2009-077T01:32:57.825 Stop Time: 2009-077T05:35:05.151
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090770827DNFS01
Start Time: 2009-077T08:27:15.389 Stop Time: 2009-077T11:00:18.874
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090771103DNFS01
Start Time: 2009-077T11:03:59.124 Stop Time: 2009-077T12:29:05.494
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090771657DNFS01
Start Time: 2009-077T16:57:40.801 Stop Time: 2009-077T19:22:48.094
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090772214DNFS01
Start Time: 2009-077T22:14:58.366 Stop Time: 2009-078T02:16:32.908
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090780508DNFS01
Start Time: 2009-078T05:08:43.145 Stop Time: 2009-078T09:09:45.561
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090781202DNFS01
Start Time: 2009-078T12:02:59.892 Stop Time: 2009-078T14:35:39.092
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090781439DNFS01
Start Time: 2009-078T14:39:19.123 Stop Time: 2009-078T16:03:53.086
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090782032DNFS01
Start Time: 2009-078T20:32:24.851 Stop Time: 2009-078T22:57:31.834
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090790150DNFS01
Start Time: 2009-079T01:50:46.194 Stop Time: 2009-079T05:51:16.516
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090790844DNFS01
Start Time: 2009-079T08:44:30.878 Stop Time: 2009-079T12:44:28.947
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090791538DNFS01
Start Time: 2009-079T15:38:47.435 Stop Time: 2009-079T18:10:54.073
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090791814DNFS01
Start Time: 2009-079T18:14:34.136 Stop Time: 2009-079T19:38:35.850
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090800007DNFS01
Start Time: 2009-080T00:07:03.814 Stop Time: 2009-080T02:32:10.854
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090800526DNFS01
Start Time: 2009-080T05:26:29.343 Stop Time: 2009-080T09:25:55.160
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090801220DNFS01
Start Time: 2009-080T12:20:13.649 Stop Time: 2009-080T16:19:38.842
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090801914DNFS01
Start Time: 2009-080T19:14:29.422 Stop Time: 2009-080T23:12:50.709
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090810208DNFS01
Start Time: 2009-081T02:08:13.381 Stop Time: 2009-081T02:24:11.855
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090810259DNFS01
Start Time: 2009-081T02:59:07.929 Stop Time: 2009-081T06:06:34.856
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090811035DNFS01
Start Time: 2009-081T10:35:22.910 Stop Time: 2009-081T13:00:29.892
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090811555DNFS01
Start Time: 2009-081T15:55:52.505 Stop Time: 2009-081T19:54:14.075
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090812250DNFS01
Start Time: 2009-081T22:50:08.785 Stop Time: 2009-082T02:47:25.816
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090820543DNFS01
Start Time: 2009-082T05:43:52.555 Stop Time: 2009-082T08:15:16.628
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090820818DNFS01
Start Time: 2009-082T08:18:56.254 Stop Time: 2009-082T09:41:21.495
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090821410DNFS01
Start Time: 2009-082T14:10:06.924 Stop Time: 2009-082T16:46:29.567
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090821931DNFS01
Start Time: 2009-082T19:31:43.025 Stop Time: 2009-082T23:29:00.378
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090830225DNFS01
Start Time: 2009-083T02:25:59.213 Stop Time: 2009-083T04:00:11.835
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090831146DNFS01
Start Time: 2009-083T11:46:48.491 Stop Time: 2009-083T13:16:12.050
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090831613DNFS01
Start Time: 2009-083T16:13:42.914 Stop Time: 2009-083T20:09:55.580
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090832307DNFS01
Start Time: 2009-083T23:07:26.445 Stop Time: 2009-084T03:03:38.952
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090840601DNFS01
Start Time: 2009-084T06:01:09.851 Stop Time: 2009-084T08:32:07.492
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090840835DNFS01
Start Time: 2009-084T08:35:47.148 Stop Time: 2009-084T09:57:08.327
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090841425DNFS01
Start Time: 2009-084T14:25:48.791 Stop Time: 2009-084T16:50:56.022
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090841949DNFS01
Start Time: 2009-084T19:49:31.014 Stop Time: 2009-084T23:44:39.367
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090850243DNFS01
Start Time: 2009-085T02:43:14.389 Stop Time: 2009-085T06:38:22.961
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090850936DNFS01
Start Time: 2009-085T09:36:57.980 Stop Time: 2009-085T11:06:21.478
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090851143DNFS01
Start Time: 2009-085T11:43:26.361 Stop Time: 2009-085T13:31:35.018
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090851800DNFS01
Start Time: 2009-085T18:00:28.773 Stop Time: 2009-085T20:25:36.286
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090852325DNFS01
Start Time: 2009-085T23:25:15.371 Stop Time: 2009-086T03:19:19.849
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090860618DNFS01
Start Time: 2009-086T06:18:58.997 Stop Time: 2009-086T10:13:02.944
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090861312DNFS01
Start Time: 2009-086T13:12:42.060 Stop Time: 2009-086T15:42:48.634
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090861546DNFS01
Start Time: 2009-086T15:46:28.135 Stop Time: 2009-086T17:06:12.908
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090862135DNFS01
Start Time: 2009-086T21:35:07.776 Stop Time: 2009-087T00:00:15.094
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090870300DNFS01
Start Time: 2009-087T03:00:58.369 Stop Time: 2009-087T06:53:58.408
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090870954DNFS01
Start Time: 2009-087T09:54:41.709 Stop Time: 2009-087T13:47:09.618
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090871816DNFS01
Start Time: 2009-087T18:16:11.905 Stop Time: 2009-087T20:41:19.200
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090872342DNFS01
Start Time: 2009-087T23:42:34.539 Stop Time: 2009-088T03:35:03.039
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090880636DNFS01
Start Time: 2009-088T06:36:18.304 Stop Time: 2009-088T10:28:47.190
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090881330DNFS01
Start Time: 2009-088T13:30:34.584 Stop Time: 2009-088T17:21:58.027
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090882150DNFS01
Start Time: 2009-088T21:50:55.922 Stop Time: 2009-089T00:27:18.560
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090890318DNFS01
Start Time: 2009-089T03:18:24.735 Stop Time: 2009-089T07:09:48.800
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090891012DNFS01
Start Time: 2009-089T10:12:08.257 Stop Time: 2009-089T14:02:59.700
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090891706DNFS01
Start Time: 2009-089T17:06:23.286 Stop Time: 2009-089T20:56:43.105
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090900125DNFS01
Start Time: 2009-090T01:25:40.796 Stop Time: 2009-090T03:50:47.998
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090900654DNFS01
Start Time: 2009-090T06:54:11.584 Stop Time: 2009-090T10:44:31.681
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090901347DNFS01
Start Time: 2009-090T13:47:55.267 Stop Time: 2009-090T17:38:14.145
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090902042DNFS01
Start Time: 2009-090T20:42:09.760 Stop Time: 2009-091T00:31:24.326
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench