• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Mars Express >> ASPERA-3
VOLUME 2: MARS EXPRESS ASPERA3 RDR ELS DATA View Errata Order Volume Toggle viewing into brief mode
MEX-M-ASPERA3-3-RDR-ELS-EXT2-V1.0 PDS 3      CERTIFIED
Start Time: 2007-10-01 21:23:50
Extension 2 calibrated data from the Electron Spectrometer (ELS) instrument of the Analyzer of Space Plasmas and Energetic Atoms experiment, 3rd edition (ASPERA-3), aboard the Mars Express spacecraft. The ASPERA-3 Principal Investigator is Dr. Rickard Lundin, Swedish Institute of Space Physics (IRF), Kiruna, Sweden. The primary source for ASPERA-3 data     more ...
Extension 2 calibrated data from the Electron Spectrometer (ELS) instrument of the Analyzer of Space Plasmas and Energetic Atoms experiment, 3rd edition (ASPERA-3), aboard the Mars Express spacecraft. The ASPERA-3 Principal Investigator is Dr. Rickard Lundin, Swedish Institute of Space Physics (IRF), Kiruna, Sweden. The primary source for ASPERA-3 data is the ESA Planetary Science Archive (PSA).    less ...
Citiation Information
Lundin, R., S. Barabash, D. Winningham, R. Frahm, MARS EXPRESS ASPERA-3 CAL RDR ELECTRON SPECTROMTR EXT2 V1.0, MEX-M-ASPERA3-3-RDR-ELS-EXT2-V1.0, ESA Planetary Science Archive (PSA), NASA Planetary Data System (PDS), 2005
Top/ DATA/ 2009/ 032_059FEB / click here to download folders and files
ELSSCIH20090320449DNFS01
Start Time: 2009-032T04:49:51.285 Stop Time: 2009-032T05:34:41.831
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090320601DNFS01
Start Time: 2009-032T06:01:11.432 Stop Time: 2009-032T10:13:24.662
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090321143DNFS01
Start Time: 2009-032T11:43:17.471 Stop Time: 2009-032T12:21:46.390
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090321503DNFS01
Start Time: 2009-032T15:03:42.408 Stop Time: 2009-032T17:06:51.255
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090321836DNFS01
Start Time: 2009-032T18:36:44.064 Stop Time: 2009-032T20:01:02.090
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090322005DNFS01
Start Time: 2009-032T20:05:13.372 Stop Time: 2009-033T00:00:22.097
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090331518DNFS01
Start Time: 2009-033T15:18:08.317 Stop Time: 2009-033T21:12:46.698
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090341159DNFS01
Start Time: 2009-034T11:59:08.248 Stop Time: 2009-034T17:22:41.404
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090341852DNFS01
Start Time: 2009-034T18:52:34.272 Stop Time: 2009-035T00:35:57.780
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090351533DNFS01
Start Time: 2009-035T15:33:44.248 Stop Time: 2009-035T16:57:40.273
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090351701DNFS01
Start Time: 2009-035T17:01:52.774 Stop Time: 2009-035T20:57:01.532
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090361214DNFS01
Start Time: 2009-036T12:14:46.416 Stop Time: 2009-036T17:38:20.232
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090361908DNFS01
Start Time: 2009-036T19:08:13.070 Stop Time: 2009-037T00:31:47.066
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090370201DNFS01
Start Time: 2009-037T02:01:39.904 Stop Time: 2009-037T03:25:53.587
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090370330DNFS01
Start Time: 2009-037T03:30:05.495 Stop Time: 2009-037T07:25:14.120
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090372242DNFS01
Start Time: 2009-037T22:42:34.375 Stop Time: 2009-038T04:06:39.565
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090380536DNFS01
Start Time: 2009-038T05:36:32.403 Stop Time: 2009-038T11:00:05.408
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090381229DNFS01
Start Time: 2009-038T12:29:58.185 Stop Time: 2009-038T17:54:11.017
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090381758DNFS01
Start Time: 2009-038T17:58:22.518 Stop Time: 2009-038T18:13:48.836
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090390911DNFS01
Start Time: 2009-039T09:11:22.403 Stop Time: 2009-039T14:34:55.928
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090391604DNFS01
Start Time: 2009-039T16:04:48.736 Stop Time: 2009-039T17:28:53.167
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090391733DNFS01
Start Time: 2009-039T17:33:04.949 Stop Time: 2009-039T21:28:13.927
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090400147DNFS01
Start Time: 2009-040T01:47:09.068 Stop Time: 2009-040T04:12:15.766
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090400612DNFS01
Start Time: 2009-040T06:12:04.116 Stop Time: 2009-040T11:05:37.236
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090401305DNFS01
Start Time: 2009-040T13:05:57.583 Stop Time: 2009-040T16:24:54.729
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090401629DNFS01
Start Time: 2009-040T16:29:07.043 Stop Time: 2009-040T17:59:34.532
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090402228DNFS01
Start Time: 2009-040T22:28:09.062 Stop Time: 2009-041T00:53:15.980
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090410253DNFS01
Start Time: 2009-041T02:53:36.392 Stop Time: 2009-041T07:46:37.125
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090410947DNFS01
Start Time: 2009-041T09:47:29.568 Stop Time: 2009-041T14:40:30.185
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090411640DNFS01
Start Time: 2009-041T16:40:50.594 Stop Time: 2009-041T19:59:30.216
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090412003DNFS01
Start Time: 2009-041T20:03:42.560 Stop Time: 2009-041T21:34:10.681
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090420202DNFS01
Start Time: 2009-042T02:02:46.058 Stop Time: 2009-042T04:27:53.007
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090420629DNFS01
Start Time: 2009-042T06:29:17.479 Stop Time: 2009-042T11:21:13.841
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090421322DNFS01
Start Time: 2009-042T13:22:38.346 Stop Time: 2009-042T18:15:06.775
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090422016DNFS01
Start Time: 2009-042T20:16:31.247 Stop Time: 2009-043T01:08:27.354
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090430310DNFS01
Start Time: 2009-043T03:10:23.981 Stop Time: 2009-043T03:44:03.523
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090430719DNFS01
Start Time: 2009-043T07:19:03.024 Stop Time: 2009-043T08:02:21.037
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090431231DNFS01
Start Time: 2009-043T12:31:02.977 Stop Time: 2009-043T14:56:09.990
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090431658DNFS01
Start Time: 2009-043T16:58:38.621 Stop Time: 2009-043T21:49:30.519
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090432351DNFS01
Start Time: 2009-043T23:51:59.182 Stop Time: 2009-044T04:43:23.203
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090440645DNFS01
Start Time: 2009-044T06:45:51.866 Stop Time: 2009-044T08:57:11.653
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090440910DNFS01
Start Time: 2009-044T09:10:17.344 Stop Time: 2009-044T10:02:25.233
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090441006DNFS01
Start Time: 2009-044T10:06:37.452 Stop Time: 2009-044T11:37:05.134
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090441605DNFS01
Start Time: 2009-044T16:05:45.056 Stop Time: 2009-044T17:52:33.025
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090441826DNFS01
Start Time: 2009-044T18:26:09.035 Stop Time: 2009-044T18:30:52.130
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090442033DNFS01
Start Time: 2009-044T20:33:52.824 Stop Time: 2009-045T01:24:13.473
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090450327DNFS01
Start Time: 2009-045T03:27:46.227 Stop Time: 2009-045T05:31:22.698
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090450609DNFS01
Start Time: 2009-045T06:09:03.396 Stop Time: 2009-045T06:43:29.686
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090450647DNFS01
Start Time: 2009-045T06:47:42.032 Stop Time: 2009-045T08:18:09.869
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090451246DNFS01
Start Time: 2009-045T12:46:41.063 Stop Time: 2009-045T14:38:35.187
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090451817DNFS01
Start Time: 2009-045T18:17:30.997 Stop Time: 2009-045T22:05:09.281
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090460009DNFS01
Start Time: 2009-046T00:09:14.131 Stop Time: 2009-046T00:55:56.896
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090460117DNFS01
Start Time: 2009-046T01:17:49.402 Stop Time: 2009-046T03:56:52.293
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090470102DNFS01
Start Time: 2009-047T01:02:26.206 Stop Time: 2009-047T01:39:50.561
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090470344DNFS01
Start Time: 2009-047T03:44:27.438 Stop Time: 2009-047T08:33:43.553
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090471302DNFS01
Start Time: 2009-047T13:02:21.036 Stop Time: 2009-047T15:38:43.429
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090471732DNFS01
Start Time: 2009-047T17:32:39.059 Stop Time: 2009-047T22:20:50.551
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090480026DNFS01
Start Time: 2009-048T00:26:31.555 Stop Time: 2009-048T05:14:43.329
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090480719DNFS01
Start Time: 2009-048T07:19:52.274 Stop Time: 2009-048T10:33:46.491
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090481037DNFS01
Start Time: 2009-048T10:37:58.555 Stop Time: 2009-048T12:08:26.143
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090481637DNFS01
Start Time: 2009-048T16:37:02.924 Stop Time: 2009-048T19:02:09.905
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090482108DNFS01
Start Time: 2009-048T21:08:22.973 Stop Time: 2009-049T01:55:30.433
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090490401DNFS01
Start Time: 2009-049T04:01:43.534 Stop Time: 2009-049T08:49:22.932
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090491055DNFS01
Start Time: 2009-049T10:55:36.000 Stop Time: 2009-049T15:42:44.430
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090491748DNFS01
Start Time: 2009-049T17:48:57.495 Stop Time: 2009-049T21:02:07.833
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090492106DNFS01
Start Time: 2009-049T21:06:19.928 Stop Time: 2009-049T22:36:47.361
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090502346DNFS01
Start Time: 2009-050T23:46:17.928 Stop Time: 2009-051T02:11:25.191
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090510419DNFS01
Start Time: 2009-051T04:19:14.510 Stop Time: 2009-051T09:04:45.682
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090511112DNFS01
Start Time: 2009-051T11:12:34.969 Stop Time: 2009-051T15:58:37.240
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090511806DNFS01
Start Time: 2009-051T18:06:26.497 Stop Time: 2009-051T22:52:29.513
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090520100DNFS01
Start Time: 2009-052T01:00:18.801 Stop Time: 2009-052T04:11:25.230
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090520415DNFS01
Start Time: 2009-052T04:15:36.950 Stop Time: 2009-052T05:46:04.599
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090521014DNFS01
Start Time: 2009-052T10:14:41.052 Stop Time: 2009-052T12:39:48.029
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090521448DNFS01
Start Time: 2009-052T14:48:41.407 Stop Time: 2009-052T15:34:07.387
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090522230DNFS01
Start Time: 2009-052T22:30:13.846 Stop Time: 2009-053T00:52:23.700
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090530056DNFS01
Start Time: 2009-053T00:56:36.012 Stop Time: 2009-053T02:27:03.723
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090531851DNFS01
Start Time: 2009-053T18:51:11.010 Stop Time: 2009-053T21:33:29.089
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090532137DNFS01
Start Time: 2009-053T21:37:40.934 Stop Time: 2009-053T23:08:08.650
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090540811DNFS01
Start Time: 2009-054T08:11:52.321 Stop Time: 2009-054T12:55:14.280
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090541505DNFS01
Start Time: 2009-054T15:05:11.756 Stop Time: 2009-054T19:49:06.467
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090550017DNFS01
Start Time: 2009-055T00:17:41.042 Stop Time: 2009-055T02:42:48.333
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090550453DNFS01
Start Time: 2009-055T04:53:17.905 Stop Time: 2009-055T09:47:55.899
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090551405DNFS01
Start Time: 2009-055T14:05:01.068 Stop Time: 2009-055T16:30:07.926
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090570510DNFS01
Start Time: 2009-057T05:10:11.498 Stop Time: 2009-057T09:51:57.268
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090571204DNFS01
Start Time: 2009-057T12:04:03.026 Stop Time: 2009-057T16:45:49.515
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20090572114DNFS01
Start Time: 2009-057T21:14:21.043 Stop Time: 2009-057T23:39:28.401
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090320449DNFS01
Start Time: 2009-032T04:49:53.160 Stop Time: 2009-032T05:34:43.925
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090320601DNFS01
Start Time: 2009-032T06:01:13.307 Stop Time: 2009-032T10:13:26.756
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090321143DNFS01
Start Time: 2009-032T11:43:19.346 Stop Time: 2009-032T12:21:48.484
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090321503DNFS01
Start Time: 2009-032T15:03:44.283 Stop Time: 2009-032T17:06:53.349
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090321836DNFS01
Start Time: 2009-032T18:36:45.939 Stop Time: 2009-032T20:01:04.184
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090322004DNFS01
Start Time: 2009-032T20:04:42.997 Stop Time: 2009-033T00:00:24.191
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090331518DNFS01
Start Time: 2009-033T15:18:10.192 Stop Time: 2009-033T21:12:48.791
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090341159DNFS01
Start Time: 2009-034T11:59:10.123 Stop Time: 2009-034T17:22:43.498
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090341852DNFS01
Start Time: 2009-034T18:52:36.147 Stop Time: 2009-035T00:35:59.874
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090351533DNFS01
Start Time: 2009-035T15:33:46.123 Stop Time: 2009-035T16:57:42.367
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090351701DNFS01
Start Time: 2009-035T17:01:22.430 Stop Time: 2009-035T20:57:03.626
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090361214DNFS01
Start Time: 2009-036T12:14:48.291 Stop Time: 2009-036T17:38:22.325
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090361908DNFS01
Start Time: 2009-036T19:08:14.945 Stop Time: 2009-037T00:31:49.160
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090370201DNFS01
Start Time: 2009-037T02:01:41.779 Stop Time: 2009-037T03:25:55.681
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090370329DNFS01
Start Time: 2009-037T03:29:35.119 Stop Time: 2009-037T07:25:16.214
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090372242DNFS01
Start Time: 2009-037T22:42:36.250 Stop Time: 2009-038T04:06:41.659
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090380536DNFS01
Start Time: 2009-038T05:36:34.278 Stop Time: 2009-038T11:00:07.502
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090381230DNFS01
Start Time: 2009-038T12:30:00.060 Stop Time: 2009-038T17:54:13.111
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090381757DNFS01
Start Time: 2009-038T17:57:52.143 Stop Time: 2009-038T18:13:50.930
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090390911DNFS01
Start Time: 2009-039T09:11:24.278 Stop Time: 2009-039T14:34:58.021
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090391604DNFS01
Start Time: 2009-039T16:04:50.611 Stop Time: 2009-039T17:28:55.260
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090391732DNFS01
Start Time: 2009-039T17:32:34.574 Stop Time: 2009-039T21:28:16.020
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090400147DNFS01
Start Time: 2009-040T01:47:10.943 Stop Time: 2009-040T04:12:17.859
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090400612DNFS01
Start Time: 2009-040T06:12:05.991 Stop Time: 2009-040T11:05:39.330
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090401305DNFS01
Start Time: 2009-040T13:05:59.458 Stop Time: 2009-040T16:24:56.823
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090401628DNFS01
Start Time: 2009-040T16:28:36.667 Stop Time: 2009-040T17:59:36.626
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090402228DNFS01
Start Time: 2009-040T22:28:10.937 Stop Time: 2009-041T00:53:18.073
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090410253DNFS01
Start Time: 2009-041T02:53:38.267 Stop Time: 2009-041T07:46:39.219
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090410947DNFS01
Start Time: 2009-041T09:47:31.443 Stop Time: 2009-041T14:40:32.279
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090411640DNFS01
Start Time: 2009-041T16:40:52.469 Stop Time: 2009-041T19:59:32.310
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090412003DNFS01
Start Time: 2009-041T20:03:12.185 Stop Time: 2009-041T21:34:12.775
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090420202DNFS01
Start Time: 2009-042T02:02:47.933 Stop Time: 2009-042T04:27:55.100
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090420629DNFS01
Start Time: 2009-042T06:29:19.354 Stop Time: 2009-042T11:21:15.935
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090421322DNFS01
Start Time: 2009-042T13:22:40.221 Stop Time: 2009-042T18:15:08.869
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090422016DNFS01
Start Time: 2009-042T20:16:33.122 Stop Time: 2009-043T01:08:29.448
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090430310DNFS01
Start Time: 2009-043T03:10:25.856 Stop Time: 2009-043T03:44:05.616
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090430719DNFS01
Start Time: 2009-043T07:19:04.899 Stop Time: 2009-043T08:02:23.130
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090431231DNFS01
Start Time: 2009-043T12:31:04.852 Stop Time: 2009-043T14:56:12.084
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090431658DNFS01
Start Time: 2009-043T16:58:40.496 Stop Time: 2009-043T21:49:32.613
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090432352DNFS01
Start Time: 2009-043T23:52:01.057 Stop Time: 2009-044T04:43:25.297
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090440645DNFS01
Start Time: 2009-044T06:45:53.741 Stop Time: 2009-044T08:57:13.746
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090440910DNFS01
Start Time: 2009-044T09:10:19.219 Stop Time: 2009-044T10:02:27.326
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090441006DNFS01
Start Time: 2009-044T10:06:07.077 Stop Time: 2009-044T11:37:07.227
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090441605DNFS01
Start Time: 2009-044T16:05:46.931 Stop Time: 2009-044T17:52:35.119
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090441826DNFS01
Start Time: 2009-044T18:26:10.910 Stop Time: 2009-044T18:30:54.224
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090442033DNFS01
Start Time: 2009-044T20:33:54.699 Stop Time: 2009-045T01:24:15.567
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090450327DNFS01
Start Time: 2009-045T03:27:48.102 Stop Time: 2009-045T05:31:24.792
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090450609DNFS01
Start Time: 2009-045T06:09:05.271 Stop Time: 2009-045T06:43:31.780
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090450647DNFS01
Start Time: 2009-045T06:47:11.656 Stop Time: 2009-045T08:18:11.963
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090451246DNFS01
Start Time: 2009-045T12:46:42.938 Stop Time: 2009-045T14:38:37.280
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090451817DNFS01
Start Time: 2009-045T18:17:32.872 Stop Time: 2009-045T22:05:11.375
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090460009DNFS01
Start Time: 2009-046T00:09:16.006 Stop Time: 2009-046T00:55:58.990
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090460117DNFS01
Start Time: 2009-046T01:17:51.277 Stop Time: 2009-046T03:56:54.387
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090470102DNFS01
Start Time: 2009-047T01:02:28.081 Stop Time: 2009-047T01:39:52.655
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090470344DNFS01
Start Time: 2009-047T03:44:29.313 Stop Time: 2009-047T08:33:45.647
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090471302DNFS01
Start Time: 2009-047T13:02:22.911 Stop Time: 2009-047T15:38:45.523
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090471732DNFS01
Start Time: 2009-047T17:32:40.934 Stop Time: 2009-047T22:20:52.645
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090480026DNFS01
Start Time: 2009-048T00:26:33.430 Stop Time: 2009-048T05:14:45.422
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090480719DNFS01
Start Time: 2009-048T07:19:54.149 Stop Time: 2009-048T10:33:48.584
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090481037DNFS01
Start Time: 2009-048T10:37:28.179 Stop Time: 2009-048T12:08:28.236
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090481637DNFS01
Start Time: 2009-048T16:37:04.799 Stop Time: 2009-048T19:02:11.998
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090482108DNFS01
Start Time: 2009-048T21:08:24.848 Stop Time: 2009-049T01:55:32.527
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090490401DNFS01
Start Time: 2009-049T04:01:45.409 Stop Time: 2009-049T08:49:25.026
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090491055DNFS01
Start Time: 2009-049T10:55:37.875 Stop Time: 2009-049T15:42:46.524
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090491748DNFS01
Start Time: 2009-049T17:48:59.370 Stop Time: 2009-049T21:02:09.927
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090492105DNFS01
Start Time: 2009-049T21:05:49.584 Stop Time: 2009-049T22:36:49.455
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090502346DNFS01
Start Time: 2009-050T23:46:19.803 Stop Time: 2009-051T02:11:27.285
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090510419DNFS01
Start Time: 2009-051T04:19:16.385 Stop Time: 2009-051T09:04:47.775
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090511112DNFS01
Start Time: 2009-051T11:12:36.844 Stop Time: 2009-051T15:58:39.333
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090511806DNFS01
Start Time: 2009-051T18:06:28.372 Stop Time: 2009-051T22:52:31.606
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090520100DNFS01
Start Time: 2009-052T01:00:20.676 Stop Time: 2009-052T04:11:27.323
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090520415DNFS01
Start Time: 2009-052T04:15:06.575 Stop Time: 2009-052T05:46:06.693
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090521014DNFS01
Start Time: 2009-052T10:14:42.927 Stop Time: 2009-052T12:39:50.123
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090521448DNFS01
Start Time: 2009-052T14:48:43.282 Stop Time: 2009-052T15:34:09.481
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090522230DNFS01
Start Time: 2009-052T22:30:15.721 Stop Time: 2009-053T00:52:25.794
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090530056DNFS01
Start Time: 2009-053T00:56:05.637 Stop Time: 2009-053T02:27:05.817
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090531851DNFS01
Start Time: 2009-053T18:51:12.885 Stop Time: 2009-053T21:33:31.183
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090532137DNFS01
Start Time: 2009-053T21:37:10.559 Stop Time: 2009-053T23:08:10.744
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090540811DNFS01
Start Time: 2009-054T08:11:54.196 Stop Time: 2009-054T12:55:16.374
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090541505DNFS01
Start Time: 2009-054T15:05:13.631 Stop Time: 2009-054T19:49:08.560
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090550017DNFS01
Start Time: 2009-055T00:17:42.917 Stop Time: 2009-055T02:42:50.426
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090550453DNFS01
Start Time: 2009-055T04:53:19.780 Stop Time: 2009-055T09:47:57.992
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090551405DNFS01
Start Time: 2009-055T14:05:02.943 Stop Time: 2009-055T16:30:10.019
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090570510DNFS01
Start Time: 2009-057T05:10:13.373 Stop Time: 2009-057T09:51:59.362
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090571204DNFS01
Start Time: 2009-057T12:04:04.901 Stop Time: 2009-057T16:45:51.609
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20090572114DNFS01
Start Time: 2009-057T21:14:22.918 Stop Time: 2009-057T23:39:30.495
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench