• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Mars Express >> ASPERA-3
VOLUME 2: MARS EXPRESS ASPERA3 RDR ELS DATA View Errata Order Volume Toggle viewing into expanded mode
MEX-M-ASPERA3-3-RDR-ELS-EXT2-V1.0 PDS 3      CERTIFIED
Start Time: 2007-10-01 21:23:50
VOLUME 2: MARS EXPRESS ASPERA3 RDR ELS DATA
VOLUME 2: MARS EXPRESS ASPERA3 RDR ELS DATA
Citiation Information
Lundin, R., S. Barabash, D. Winningham, R. Frahm, MARS EXPRESS ASPERA-3 CAL RDR ELECTRON SPECTROMTR EXT2 V1.0, MEX-M-ASPERA3-3-RDR-ELS-EXT2-V1.0, ESA Planetary Science Archive (PSA), NASA Planetary Data System (PDS), 2005
Top/ DATA/ 2008/ 306_335NOV / click here to download folders and files
ELSSCIH20083060739DNFS01
Start Time: 2008-306T07:39:52.260 Stop Time: 2008-306T10:46:46.817
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083061430DNFS01
Start Time: 2008-306T14:30:15.258 Stop Time: 2008-306T17:37:42.375
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083062120DNFS01
Start Time: 2008-306T21:20:38.806 Stop Time: 2008-306T22:04:34.819
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083062208DNFS01
Start Time: 2008-306T22:08:46.851 Stop Time: 2008-307T00:28:32.391
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083071101DNFS01
Start Time: 2008-307T11:01:33.953 Stop Time: 2008-307T12:33:38.012
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083071310DNFS01
Start Time: 2008-307T13:10:42.712 Stop Time: 2008-307T14:10:05.512
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083071751DNFS01
Start Time: 2008-307T17:51:57.858 Stop Time: 2008-307T19:35:49.324
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083072052DNFS01
Start Time: 2008-307T20:52:33.348 Stop Time: 2008-307T21:01:01.475
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083080042DNFS01
Start Time: 2008-308T00:42:21.725 Stop Time: 2008-308T01:27:28.052
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083080131DNFS01
Start Time: 2008-308T01:31:39.709 Stop Time: 2008-308T03:05:20.327
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083151122DNFS01
Start Time: 2008-315T11:22:29.246 Stop Time: 2008-315T13:52:57.541
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083151722DNFS01
Start Time: 2008-315T17:22:32.384 Stop Time: 2008-315T17:49:13.579
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083151914DNFS01
Start Time: 2008-315T19:14:32.101 Stop Time: 2008-315T20:55:10.129
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083160012DNFS01
Start Time: 2008-316T00:12:59.564 Stop Time: 2008-316T01:07:01.737
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083160111DNFS01
Start Time: 2008-316T01:11:13.893 Stop Time: 2008-316T01:26:07.710
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083160158DNFS01
Start Time: 2008-316T01:58:27.717 Stop Time: 2008-316T03:34:12.933
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083161353DNFS01
Start Time: 2008-316T13:53:54.952 Stop Time: 2008-316T14:27:34.432
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083161557DNFS01
Start Time: 2008-316T15:57:10.175 Stop Time: 2008-316T17:15:50.135
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083162043DNFS01
Start Time: 2008-316T20:43:48.886 Stop Time: 2008-316T23:32:22.658
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083170004DNFS01
Start Time: 2008-317T00:04:45.856 Stop Time: 2008-317T00:06:48.169
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083170334DNFS01
Start Time: 2008-317T03:34:14.827 Stop Time: 2008-317T05:36:19.128
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083171041DNFS01
Start Time: 2008-317T10:41:49.720 Stop Time: 2008-317T11:20:24.794
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083171124DNFS01
Start Time: 2008-317T11:24:37.389 Stop Time: 2008-317T13:13:50.264
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083180005DNFS01
Start Time: 2008-318T00:05:42.707 Stop Time: 2008-318T03:30:18.266
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083180656DNFS01
Start Time: 2008-318T06:56:08.766 Stop Time: 2008-318T07:16:00.337
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083180749DNFS01
Start Time: 2008-318T07:49:09.875 Stop Time: 2008-318T07:52:36.127
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083180756DNFS01
Start Time: 2008-318T07:56:48.345 Stop Time: 2008-318T09:28:20.364
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083182041DNFS01
Start Time: 2008-318T20:41:27.884 Stop Time: 2008-319T00:02:18.225
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083190327DNFS01
Start Time: 2008-319T03:27:04.507 Stop Time: 2008-319T06:53:17.251
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083191017DNFS01
Start Time: 2008-319T10:17:31.500 Stop Time: 2008-319T11:15:19.579
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083191119DNFS01
Start Time: 2008-319T11:19:31.860 Stop Time: 2008-319T13:44:06.747
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083192357DNFS01
Start Time: 2008-319T23:57:52.226 Stop Time: 2008-320T03:25:40.879
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083200648DNFS01
Start Time: 2008-320T06:48:18.905 Stop Time: 2008-320T10:16:08.121
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083201338DNFS01
Start Time: 2008-320T13:38:46.147 Stop Time: 2008-320T14:37:53.726
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083201442DNFS01
Start Time: 2008-320T14:42:05.696 Stop Time: 2008-320T17:07:12.928
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083210319DNFS01
Start Time: 2008-321T03:19:27.236 Stop Time: 2008-321T06:48:52.580
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083211009DNFS01
Start Time: 2008-321T10:09:54.451 Stop Time: 2008-321T13:39:19.949
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083211700DNFS01
Start Time: 2008-321T17:00:21.853 Stop Time: 2008-321T17:14:11.575
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083211718DNFS01
Start Time: 2008-321T17:18:02.858 Stop Time: 2008-321T18:00:45.714
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20083211804DNFS01
Start Time: 2008-321T18:04:57.870 Stop Time: 2008-321T20:30:04.910
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIH:  Electron Spectrometer (ELS) science data (SCI)
from the high range (H) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083060739DNFS01
Start Time: 2008-306T07:39:54.135 Stop Time: 2008-306T10:46:48.911
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083061430DNFS01
Start Time: 2008-306T14:30:17.133 Stop Time: 2008-306T17:37:44.469
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083062120DNFS01
Start Time: 2008-306T21:20:40.681 Stop Time: 2008-306T22:04:36.912
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083062208DNFS01
Start Time: 2008-306T22:08:16.476 Stop Time: 2008-307T00:28:34.484
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083071101DNFS01
Start Time: 2008-307T11:01:35.828 Stop Time: 2008-307T12:33:40.106
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083071310DNFS01
Start Time: 2008-307T13:10:44.587 Stop Time: 2008-307T14:10:07.606
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083071751DNFS01
Start Time: 2008-307T17:51:59.733 Stop Time: 2008-307T19:35:51.418
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083072052DNFS01
Start Time: 2008-307T20:52:35.223 Stop Time: 2008-307T21:01:03.569
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083080042DNFS01
Start Time: 2008-308T00:42:23.600 Stop Time: 2008-308T01:27:30.145
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083080131DNFS01
Start Time: 2008-308T01:31:09.365 Stop Time: 2008-308T03:05:22.420
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083090422DNFS01
Start Time: 2008-309T04:22:18.151 Stop Time: 2008-309T04:50:21.661
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083090454DNFS01
Start Time: 2008-309T04:54:01.504 Stop Time: 2008-309T07:15:02.297
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083091744DNFS01
Start Time: 2008-309T17:44:37.556 Stop Time: 2008-309T20:56:56.203
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083100035DNFS01
Start Time: 2008-310T00:35:01.924 Stop Time: 2008-310T01:22:21.345
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083100126DNFS01
Start Time: 2008-310T01:26:00.970 Stop Time: 2008-310T03:47:34.072
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083101415DNFS01
Start Time: 2008-310T14:15:29.434 Stop Time: 2008-310T17:28:20.465
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083102126DNFS01
Start Time: 2008-310T21:26:44.531 Stop Time: 2008-310T23:49:21.641
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083110430DNFS01
Start Time: 2008-311T04:30:30.727 Stop Time: 2008-311T07:10:45.670
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083111046DNFS01
Start Time: 2008-311T10:46:43.079 Stop Time: 2008-311T14:01:42.230
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083120027DNFS01
Start Time: 2008-312T00:27:29.329 Stop Time: 2008-312T03:43:00.546
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083120717DNFS01
Start Time: 2008-312T07:17:53.825 Stop Time: 2008-312T07:50:25.553
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083120821DNFS01
Start Time: 2008-312T08:21:29.280 Stop Time: 2008-312T10:33:57.099
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083121408DNFS01
Start Time: 2008-312T14:08:18.409 Stop Time: 2008-312T14:19:59.693
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083121526DNFS01
Start Time: 2008-312T15:26:58.716 Stop Time: 2008-312T17:25:00.686
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083131047DNFS01
Start Time: 2008-313T10:47:09.576 Stop Time: 2008-313T13:57:20.283
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083131730DNFS01
Start Time: 2008-313T17:30:05.341 Stop Time: 2008-313T18:21:30.009
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083131825DNFS01
Start Time: 2008-313T18:25:09.604 Stop Time: 2008-313T19:48:27.597
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083132037DNFS01
Start Time: 2008-313T20:37:09.393 Stop Time: 2008-313T20:48:18.615
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083140710DNFS01
Start Time: 2008-314T07:10:57.004 Stop Time: 2008-314T07:47:45.232
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083140926DNFS01
Start Time: 2008-314T09:26:09.201 Stop Time: 2008-314T10:29:40.563
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083141400DNFS01
Start Time: 2008-314T14:00:49.403 Stop Time: 2008-314T17:20:36.963
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083142051DNFS01
Start Time: 2008-314T20:51:13.746 Stop Time: 2008-314T21:44:15.137
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083142208DNFS01
Start Time: 2008-314T22:08:44.926 Stop Time: 2008-314T23:51:25.237
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083151122DNFS01
Start Time: 2008-315T11:22:31.121 Stop Time: 2008-315T13:52:59.635
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083151722DNFS01
Start Time: 2008-315T17:22:34.259 Stop Time: 2008-315T17:49:15.673
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083151914DNFS01
Start Time: 2008-315T19:14:33.976 Stop Time: 2008-315T20:55:12.222
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083160013DNFS01
Start Time: 2008-316T00:13:01.439 Stop Time: 2008-316T01:07:03.830
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083160110DNFS01
Start Time: 2008-316T01:10:43.518 Stop Time: 2008-316T01:26:09.803
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083160158DNFS01
Start Time: 2008-316T01:58:29.592 Stop Time: 2008-316T03:34:15.026
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083161353DNFS01
Start Time: 2008-316T13:53:56.827 Stop Time: 2008-316T14:27:36.525
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083161557DNFS01
Start Time: 2008-316T15:57:12.050 Stop Time: 2008-316T17:15:52.229
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083162043DNFS01
Start Time: 2008-316T20:43:50.761 Stop Time: 2008-316T23:32:24.752
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083170004DNFS01
Start Time: 2008-317T00:04:47.731 Stop Time: 2008-317T00:06:50.263
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083170334DNFS01
Start Time: 2008-317T03:34:16.702 Stop Time: 2008-317T05:36:21.222
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083171041DNFS01
Start Time: 2008-317T10:41:51.595 Stop Time: 2008-317T11:20:26.888
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083171124DNFS01
Start Time: 2008-317T11:24:06.982 Stop Time: 2008-317T13:13:52.358
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083180005DNFS01
Start Time: 2008-318T00:05:44.582 Stop Time: 2008-318T03:30:20.360
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083180656DNFS01
Start Time: 2008-318T06:56:10.641 Stop Time: 2008-318T07:16:02.431
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083180748DNFS01
Start Time: 2008-318T07:48:57.907 Stop Time: 2008-318T07:52:38.221
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083180756DNFS01
Start Time: 2008-318T07:56:17.970 Stop Time: 2008-318T09:28:22.458
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083182041DNFS01
Start Time: 2008-318T20:41:29.759 Stop Time: 2008-319T00:02:20.319
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083190327DNFS01
Start Time: 2008-319T03:27:06.382 Stop Time: 2008-319T06:53:19.345
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083191017DNFS01
Start Time: 2008-319T10:17:33.375 Stop Time: 2008-319T11:15:21.672
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083191119DNFS01
Start Time: 2008-319T11:19:01.454 Stop Time: 2008-319T13:44:08.840
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083192357DNFS01
Start Time: 2008-319T23:57:54.101 Stop Time: 2008-320T03:25:42.972
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083200648DNFS01
Start Time: 2008-320T06:48:20.780 Stop Time: 2008-320T10:16:10.215
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083201338DNFS01
Start Time: 2008-320T13:38:48.022 Stop Time: 2008-320T14:37:55.820
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083201441DNFS01
Start Time: 2008-320T14:41:35.352 Stop Time: 2008-320T17:07:15.022
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083210319DNFS01
Start Time: 2008-321T03:19:29.111 Stop Time: 2008-321T06:48:54.674
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083211009DNFS01
Start Time: 2008-321T10:09:56.326 Stop Time: 2008-321T13:39:22.043
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083211700DNFS01
Start Time: 2008-321T17:00:23.728 Stop Time: 2008-321T17:14:13.669
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083211718DNFS01
Start Time: 2008-321T17:18:04.733 Stop Time: 2008-321T18:00:47.808
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20083211804DNFS01
Start Time: 2008-321T18:04:27.495 Stop Time: 2008-321T20:30:07.004
This file contains calibrated data (in differential number flux [DNF]
units) from ELSSCIL:  Electron Spectrometer (ELS) science data (SCI)
from the low range (L) of the ELS power supply with up to 128 steps
returned in telemetry.  These step values are in the SCAN rows of the
data files in the form of deflection potential (volts).  To convert
each step per sector to center electron energies (eV), use the
K_FACTORS in the calibration tables (K-factor * defl. volt = eV).
Each SCAN row directly corresponds to the previous 16 SENSOR rows
where the SENSOR value (Diff. Num Flux) in a given column is the data
sampled at the SCAN value (deflection voltage) in that same column.
The SENSOR rows have one more column than the SCAN rows.  The
additional column is the data quality indicator (last column) for
that sensor data.  The data values are formatted for a high level
of accuracy and DO NOT reflect the accuracy of the intrumentation.
The ELS Instrument is mounted on a scanning platform that was
activated for the first time in January 2006.  The scanner may have
moved from its parked position or be in motion for some of this data.
Please refer to the Data Set Catalog, ASPERA3_RDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench