• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Mars Express >> ASPERA-3
VOLUME 1: MARS EXPRESS ASPERA3 EDR ELS DATA View Errata Order Volume Toggle viewing into expanded mode
MEX-M-ASPERA3-2-EDR-ELS-EXT3-V1.0 PDS 3      CERTIFIED
Start Time: 2010-01-02 07:50:15 - Stop Time: 2013-01-01 13:29:19
VOLUME 1: MARS EXPRESS ASPERA3 EDR ELS DATA
VOLUME 1: MARS EXPRESS ASPERA3 EDR ELS DATA
Citiation Information
Lundin, R., S. Barabash, D. Winningham, R. Frahm, MARS EXPRESS ASPERA-3 RAW EDR ELECTRON SPECTROMTR EXT3 V1.0, MEX-M-ASPERA3-2-EDR-ELS-EXT3-V1.0, ESA Planetary Science Archive (PSA), NASA Planetary Data System (PDS), 2005
Top/ DATA/ 2010/ 091_120APR / click here to download folders and files
ELSSCIH20100910428C_ACCS01
Start Time: 2010-091T04:28:20.668 Stop Time: 2010-091T07:30:26.535
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100911128C_ACCS01
Start Time: 2010-091T11:28:20.733 Stop Time: 2010-091T14:30:26.443
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100911827C_ACCS01
Start Time: 2010-091T18:27:48.578 Stop Time: 2010-091T21:29:53.881
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100920127C_ACCS01
Start Time: 2010-092T01:27:48.044 Stop Time: 2010-092T05:04:43.266
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100920903C_ACCS01
Start Time: 2010-092T09:03:58.993 Stop Time: 2010-092T12:04:27.479
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100921527C_ACCS01
Start Time: 2010-092T15:27:37.633 Stop Time: 2010-092T18:28:39.031
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100922227C_ACCS01
Start Time: 2010-092T22:27:05.315 Stop Time: 2010-093T01:28:39.244
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100930527C_ACCS01
Start Time: 2010-093T05:27:05.470 Stop Time: 2010-093T08:28:06.367
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100931227C_ACCS01
Start Time: 2010-093T12:27:04.717 Stop Time: 2010-093T13:23:21.108
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100931327C_ACCS01
Start Time: 2010-093T13:27:33.547 Stop Time: 2010-093T16:02:51.898
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100932002C_ACCS01
Start Time: 2010-093T20:02:06.994 Stop Time: 2010-093T23:02:36.763
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100940226C_ACCS01
Start Time: 2010-094T02:26:51.044 Stop Time: 2010-094T05:27:20.412
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100940926C_ACCS01
Start Time: 2010-094T09:26:50.857 Stop Time: 2010-094T12:26:48.753
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100941626C_ACCS01
Start Time: 2010-094T16:26:19.128 Stop Time: 2010-094T19:26:17.151
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100950700C_ACCS01
Start Time: 2010-095T07:00:15.055 Stop Time: 2010-095T10:07:09.901
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100951325C_ACCS01
Start Time: 2010-095T13:25:31.524 Stop Time: 2010-095T16:55:29.117
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100952025C_ACCS01
Start Time: 2010-095T20:25:03.992 Stop Time: 2010-095T21:35:32.231
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100952139C_ACCS01
Start Time: 2010-095T21:39:44.514 Stop Time: 2010-095T23:54:41.181
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100960359C_ACCS01
Start Time: 2010-096T03:59:20.973 Stop Time: 2010-096T06:54:28.776
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100961024C_ACCS01
Start Time: 2010-096T10:24:35.682 Stop Time: 2010-096T13:54:01.308
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100961724C_ACCS01
Start Time: 2010-096T17:24:08.275 Stop Time: 2010-096T18:34:27.170
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100961838C_ACCS01
Start Time: 2010-096T18:38:39.484 Stop Time: 2010-096T20:53:35.525
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100970058C_ACCS01
Start Time: 2010-097T00:58:06.997 Stop Time: 2010-097T03:53:14.735
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100970723C_ACCS01
Start Time: 2010-097T07:23:21.673 Stop Time: 2010-097T10:52:47.580
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100971422C_ACCS01
Start Time: 2010-097T14:22:54.545 Stop Time: 2010-097T17:52:51.890
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100972122C_ACCS01
Start Time: 2010-097T21:22:26.763 Stop Time: 2010-097T22:32:58.445
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100972237C_ACCS01
Start Time: 2010-097T22:37:11.071 Stop Time: 2010-098T00:52:07.549
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100980456C_ACCS01
Start Time: 2010-098T04:56:46.990 Stop Time: 2010-098T07:51:54.294
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100981122C_ACCS01
Start Time: 2010-098T11:22:01.201 Stop Time: 2010-098T14:51:26.418
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100981821C_ACCS01
Start Time: 2010-098T18:21:33.392 Stop Time: 2010-098T21:50:58.672
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100990121C_ACCS01
Start Time: 2010-099T01:21:05.548 Stop Time: 2010-099T02:31:26.789
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100990235C_ACCS01
Start Time: 2010-099T02:35:39.102 Stop Time: 2010-099T04:50:35.048
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100990855C_ACCS01
Start Time: 2010-099T08:55:10.142 Stop Time: 2010-099T11:50:18.069
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100991520C_ACCS01
Start Time: 2010-099T15:20:25.006 Stop Time: 2010-099T18:50:22.567
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20100992219C_ACCS01
Start Time: 2010-099T22:19:57.474 Stop Time: 2010-100T01:48:18.878
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101001953C_ACCS01
Start Time: 2010-100T19:53:23.052 Stop Time: 2010-100T22:48:30.069
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101010218C_ACCS01
Start Time: 2010-101T02:18:37.040 Stop Time: 2010-101T05:48:02.322
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101010918C_ACCS01
Start Time: 2010-101T09:18:09.261 Stop Time: 2010-101T10:28:32.502
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101011032C_ACCS01
Start Time: 2010-101T10:32:45.066 Stop Time: 2010-101T12:47:41.135
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101011652C_ACCS01
Start Time: 2010-101T16:52:20.997 Stop Time: 2010-101T19:47:28.769
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101012317C_ACCS01
Start Time: 2010-101T23:17:35.738 Stop Time: 2010-102T02:47:01.335
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101020617C_ACCS01
Start Time: 2010-102T06:17:08.305 Stop Time: 2010-102T09:47:05.588
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101021316C_ACCS01
Start Time: 2010-102T13:16:40.496 Stop Time: 2010-102T14:22:08.921
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101021426C_ACCS01
Start Time: 2010-102T14:26:21.079 Stop Time: 2010-102T16:46:38.148
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101022050C_ACCS01
Start Time: 2010-102T20:50:51.014 Stop Time: 2010-102T23:45:58.163
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101030316C_ACCS01
Start Time: 2010-103T03:16:05.127 Stop Time: 2010-103T06:45:29.906
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101031015C_ACCS01
Start Time: 2010-103T10:15:36.873 Stop Time: 2010-103T13:45:34.312
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101031715C_ACCS01
Start Time: 2010-103T17:15:09.185 Stop Time: 2010-103T20:45:06.281
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101040014C_ACCS01
Start Time: 2010-104T00:14:41.122 Stop Time: 2010-104T01:25:23.389
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101040129C_ACCS01
Start Time: 2010-104T01:29:35.703 Stop Time: 2010-104T03:44:31.926
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101040749C_ACCS01
Start Time: 2010-104T07:49:12.989 Stop Time: 2010-104T10:44:20.948
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101041414C_ACCS01
Start Time: 2010-104T14:14:27.949 Stop Time: 2010-104T17:43:53.294
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101042114C_ACCS01
Start Time: 2010-104T21:14:00.266 Stop Time: 2010-105T00:43:25.860
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101050413C_ACCS01
Start Time: 2010-105T04:13:32.735 Stop Time: 2010-105T07:43:30.387
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101051113C_ACCS01
Start Time: 2010-105T11:13:05.262 Stop Time: 2010-105T12:23:39.501
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101051227C_ACCS01
Start Time: 2010-105T12:27:51.691 Stop Time: 2010-105T14:42:47.795
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101051847C_ACCS01
Start Time: 2010-105T18:47:28.986 Stop Time: 2010-105T21:42:36.723
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101060112C_ACCS01
Start Time: 2010-106T01:12:43.691 Stop Time: 2010-106T04:42:09.254
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101060812C_ACCS01
Start Time: 2010-106T08:12:16.160 Stop Time: 2010-106T09:07:44.113
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101060911C_ACCS01
Start Time: 2010-106T09:11:56.364 Stop Time: 2010-106T11:41:52.941
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101070511C_ACCS01
Start Time: 2010-107T05:11:15.114 Stop Time: 2010-107T08:41:12.771
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101071210C_ACCS01
Start Time: 2010-107T12:10:47.647 Stop Time: 2010-107T15:40:45.400
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101071910C_ACCS01
Start Time: 2010-107T19:10:20.243 Stop Time: 2010-107T20:21:01.764
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101072025C_ACCS01
Start Time: 2010-107T20:25:14.109 Stop Time: 2010-107T22:40:09.776
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101080244C_ACCS01
Start Time: 2010-108T02:44:43.031 Stop Time: 2010-108T05:39:49.988
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101080909C_ACCS01
Start Time: 2010-108T09:09:56.927 Stop Time: 2010-108T12:39:54.490
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101081609C_ACCS01
Start Time: 2010-108T16:09:29.363 Stop Time: 2010-108T19:39:27.016
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101082309C_ACCS01
Start Time: 2010-108T23:09:01.894 Stop Time: 2010-109T00:19:32.665
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101090023C_ACCS01
Start Time: 2010-109T00:23:45.135 Stop Time: 2010-109T02:38:41.427
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101090643C_ACCS01
Start Time: 2010-109T06:43:14.111 Stop Time: 2010-109T09:38:21.224
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101091308C_ACCS01
Start Time: 2010-109T13:08:28.257 Stop Time: 2010-109T16:38:25.755
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101092008C_ACCS01
Start Time: 2010-109T20:08:00.659 Stop Time: 2010-109T21:18:32.242
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101092122C_ACCS01
Start Time: 2010-109T21:22:44.619 Stop Time: 2010-109T23:37:41.157
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101100342C_ACCS01
Start Time: 2010-110T03:42:10.918 Stop Time: 2010-110T06:37:18.876
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101101007C_ACCS01
Start Time: 2010-110T10:07:25.782 Stop Time: 2010-110T13:36:51.156
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101101706C_ACCS01
Start Time: 2010-110T17:06:58.126 Stop Time: 2010-110T20:36:23.058
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101110006C_ACCS01
Start Time: 2010-111T00:06:29.966 Stop Time: 2010-111T00:36:59.101
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101110041C_ACCS01
Start Time: 2010-111T00:41:11.196 Stop Time: 2010-111T03:36:18.969
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101110740C_ACCS01
Start Time: 2010-111T07:40:43.136 Stop Time: 2010-111T10:35:50.691
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101111405C_ACCS01
Start Time: 2010-111T14:05:57.631 Stop Time: 2010-111T17:35:55.192
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101112105C_ACCS01
Start Time: 2010-111T21:05:30.159 Stop Time: 2010-111T22:15:59.117
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101112220C_ACCS01
Start Time: 2010-111T22:20:11.118 Stop Time: 2010-112T00:35:07.188
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101120439C_ACCS01
Start Time: 2010-112T04:39:38.128 Stop Time: 2010-112T07:34:46.210
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101121104C_ACCS01
Start Time: 2010-112T11:04:53.147 Stop Time: 2010-112T14:34:18.396
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101121804C_ACCS01
Start Time: 2010-112T18:04:25.367 Stop Time: 2010-112T21:33:50.773
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101130103C_ACCS01
Start Time: 2010-113T01:03:57.681 Stop Time: 2010-113T04:33:55.241
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101130803C_ACCS01
Start Time: 2010-113T08:03:30.114 Stop Time: 2010-113T08:33:57.402
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101130838C_ACCS01
Start Time: 2010-113T08:38:09.497 Stop Time: 2010-113T11:33:17.456
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101131537C_ACCS01
Start Time: 2010-113T15:37:47.139 Stop Time: 2010-113T18:32:54.847
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101132203C_ACCS01
Start Time: 2010-113T22:03:01.816 Stop Time: 2010-114T01:32:27.596
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101140502C_ACCS01
Start Time: 2010-114T05:02:34.501 Stop Time: 2010-114T08:32:00.627
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101141202C_ACCS01
Start Time: 2010-114T12:02:07.536 Stop Time: 2010-114T13:12:27.119
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101141316C_ACCS01
Start Time: 2010-114T13:16:38.743 Stop Time: 2010-114T15:31:34.812
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101141936C_ACCS01
Start Time: 2010-114T19:36:03.006 Stop Time: 2010-114T22:31:10.092
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101150201C_ACCS01
Start Time: 2010-115T02:01:17.025 Stop Time: 2010-115T05:31:14.183
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101150900C_ACCS01
Start Time: 2010-115T09:00:49.057 Stop Time: 2010-115T12:30:46.743
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101151600C_ACCS01
Start Time: 2010-115T16:00:21.650 Stop Time: 2010-115T19:30:18.714
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101152259C_ACCS01
Start Time: 2010-115T22:59:53.615 Stop Time: 2010-115T23:30:33.374
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101152334C_ACCS01
Start Time: 2010-115T23:34:45.844 Stop Time: 2010-116T02:29:53.709
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101160634C_ACCS01
Start Time: 2010-116T06:34:11.018 Stop Time: 2010-116T09:29:18.945
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101161259C_ACCS01
Start Time: 2010-116T12:59:25.911 Stop Time: 2010-116T16:28:50.915
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101161958C_ACCS01
Start Time: 2010-116T19:58:57.881 Stop Time: 2010-116T21:09:11.995
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101162113C_ACCS01
Start Time: 2010-116T21:13:24.527 Stop Time: 2010-116T23:28:20.878
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101170333C_ACCS01
Start Time: 2010-117T03:33:01.011 Stop Time: 2010-117T06:28:09.031
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101170958C_ACCS01
Start Time: 2010-117T09:58:15.937 Stop Time: 2010-117T13:27:40.876
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101171657C_ACCS01
Start Time: 2010-117T16:57:47.785 Stop Time: 2010-117T20:27:45.682
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101172357C_ACCS01
Start Time: 2010-117T23:57:20.562 Stop Time: 2010-118T00:27:50.883
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101180032C_ACCS01
Start Time: 2010-118T00:32:03.291 Stop Time: 2010-118T03:27:10.967
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101180731C_ACCS01
Start Time: 2010-118T07:31:30.047 Stop Time: 2010-118T10:26:37.910
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101181356C_ACCS01
Start Time: 2010-118T13:56:44.819 Stop Time: 2010-118T17:26:10.475
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101182056C_ACCS01
Start Time: 2010-118T20:56:17.351 Stop Time: 2010-119T00:25:42.257
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101190355C_ACCS01
Start Time: 2010-119T03:55:49.193 Stop Time: 2010-119T05:06:14.807
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101190510C_ACCS01
Start Time: 2010-119T05:10:26.652 Stop Time: 2010-119T07:25:22.848
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101191129C_ACCS01
Start Time: 2010-119T11:29:59.008 Stop Time: 2010-119T14:25:06.216
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101191755C_ACCS01
Start Time: 2010-119T17:55:13.188 Stop Time: 2010-119T21:25:09.937
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101200054C_ACCS01
Start Time: 2010-120T00:54:44.845 Stop Time: 2010-120T02:05:14.019
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101200209C_ACCS01
Start Time: 2010-120T02:09:26.488 Stop Time: 2010-120T04:24:23.155
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101200828C_ACCS01
Start Time: 2010-120T08:28:54.106 Stop Time: 2010-120T11:24:02.129
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101201454C_ACCS01
Start Time: 2010-120T14:54:09.061 Stop Time: 2010-120T18:23:34.593
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101202153C_ACCS01
Start Time: 2010-120T21:53:41.502 Stop Time: 2010-120T23:03:58.835
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIH20101202308C_ACCS01
Start Time: 2010-120T23:08:11.429 Stop Time: 2010-121T01:23:07.625
This file contains data from ELSSCIH:  Electron Spectrometer (ELS)
science data (SCI) from the high range (H) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100910428C_ACCS01
Start Time: 2010-091T04:28:22.543 Stop Time: 2010-091T07:30:28.629
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100911128C_ACCS01
Start Time: 2010-091T11:28:22.608 Stop Time: 2010-091T14:30:28.537
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100911827C_ACCS01
Start Time: 2010-091T18:27:50.453 Stop Time: 2010-091T21:29:55.975
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100920127C_ACCS01
Start Time: 2010-092T01:27:49.919 Stop Time: 2010-092T05:04:45.360
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100920904C_ACCS01
Start Time: 2010-092T09:04:00.868 Stop Time: 2010-092T12:04:29.572
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100921527C_ACCS01
Start Time: 2010-092T15:27:39.508 Stop Time: 2010-092T18:28:41.125
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100922227C_ACCS01
Start Time: 2010-092T22:27:07.190 Stop Time: 2010-093T01:28:41.338
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100930527C_ACCS01
Start Time: 2010-093T05:27:07.345 Stop Time: 2010-093T08:28:08.461
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100931227C_ACCS01
Start Time: 2010-093T12:27:06.592 Stop Time: 2010-093T13:23:23.202
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100931327C_ACCS01
Start Time: 2010-093T13:27:03.172 Stop Time: 2010-093T16:02:53.992
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100932002C_ACCS01
Start Time: 2010-093T20:02:08.869 Stop Time: 2010-093T23:02:38.856
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100940226C_ACCS01
Start Time: 2010-094T02:26:52.919 Stop Time: 2010-094T05:27:22.506
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100940926C_ACCS01
Start Time: 2010-094T09:26:52.732 Stop Time: 2010-094T12:26:50.847
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100941626C_ACCS01
Start Time: 2010-094T16:26:21.003 Stop Time: 2010-094T19:26:19.245
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100950700C_ACCS01
Start Time: 2010-095T07:00:16.930 Stop Time: 2010-095T10:07:11.994
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100951325C_ACCS01
Start Time: 2010-095T13:25:33.399 Stop Time: 2010-095T16:55:31.211
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100952025C_ACCS01
Start Time: 2010-095T20:25:05.867 Stop Time: 2010-095T21:35:34.325
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100952139C_ACCS01
Start Time: 2010-095T21:39:14.170 Stop Time: 2010-095T23:54:43.275
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100960359C_ACCS01
Start Time: 2010-096T03:59:22.848 Stop Time: 2010-096T06:54:30.870
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100961024C_ACCS01
Start Time: 2010-096T10:24:37.557 Stop Time: 2010-096T13:54:03.402
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100961724C_ACCS01
Start Time: 2010-096T17:24:10.150 Stop Time: 2010-096T18:34:29.264
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100961838C_ACCS01
Start Time: 2010-096T18:38:09.108 Stop Time: 2010-096T20:53:37.618
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100970058C_ACCS01
Start Time: 2010-097T00:58:08.872 Stop Time: 2010-097T03:53:16.828
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100970723C_ACCS01
Start Time: 2010-097T07:23:23.548 Stop Time: 2010-097T10:52:49.674
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100971422C_ACCS01
Start Time: 2010-097T14:22:56.420 Stop Time: 2010-097T17:52:53.984
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100972122C_ACCS01
Start Time: 2010-097T21:22:28.638 Stop Time: 2010-097T22:33:00.539
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100972236C_ACCS01
Start Time: 2010-097T22:36:40.727 Stop Time: 2010-098T00:52:09.643
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100980456C_ACCS01
Start Time: 2010-098T04:56:48.865 Stop Time: 2010-098T07:51:56.387
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100981122C_ACCS01
Start Time: 2010-098T11:22:03.076 Stop Time: 2010-098T14:51:28.511
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100981821C_ACCS01
Start Time: 2010-098T18:21:35.267 Stop Time: 2010-098T21:51:00.766
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100990121C_ACCS01
Start Time: 2010-099T01:21:07.423 Stop Time: 2010-099T02:31:28.883
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100990235C_ACCS01
Start Time: 2010-099T02:35:08.727 Stop Time: 2010-099T04:50:37.142
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100990855C_ACCS01
Start Time: 2010-099T08:55:12.017 Stop Time: 2010-099T11:50:20.163
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100991520C_ACCS01
Start Time: 2010-099T15:20:26.881 Stop Time: 2010-099T18:50:24.661
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20100992219C_ACCS01
Start Time: 2010-099T22:19:59.349 Stop Time: 2010-100T01:48:20.971
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101001953C_ACCS01
Start Time: 2010-100T19:53:24.927 Stop Time: 2010-100T22:48:32.163
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101010218C_ACCS01
Start Time: 2010-101T02:18:38.915 Stop Time: 2010-101T05:48:04.416
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101010918C_ACCS01
Start Time: 2010-101T09:18:11.136 Stop Time: 2010-101T10:28:34.595
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101011032C_ACCS01
Start Time: 2010-101T10:32:14.691 Stop Time: 2010-101T12:47:43.228
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101011652C_ACCS01
Start Time: 2010-101T16:52:22.872 Stop Time: 2010-101T19:47:30.863
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101012317C_ACCS01
Start Time: 2010-101T23:17:37.613 Stop Time: 2010-102T02:47:03.429
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101020617C_ACCS01
Start Time: 2010-102T06:17:10.180 Stop Time: 2010-102T09:47:07.682
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101021316C_ACCS01
Start Time: 2010-102T13:16:42.371 Stop Time: 2010-102T14:22:11.015
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101021425C_ACCS01
Start Time: 2010-102T14:25:50.703 Stop Time: 2010-102T16:46:40.242
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101022050C_ACCS01
Start Time: 2010-102T20:50:52.889 Stop Time: 2010-102T23:46:00.256
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101030316C_ACCS01
Start Time: 2010-103T03:16:07.002 Stop Time: 2010-103T06:45:31.999
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101031015C_ACCS01
Start Time: 2010-103T10:15:38.748 Stop Time: 2010-103T13:45:36.406
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101031715C_ACCS01
Start Time: 2010-103T17:15:11.060 Stop Time: 2010-103T20:45:08.375
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101040014C_ACCS01
Start Time: 2010-104T00:14:42.997 Stop Time: 2010-104T01:25:25.483
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101040129C_ACCS01
Start Time: 2010-104T01:29:05.327 Stop Time: 2010-104T03:44:34.020
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101040749C_ACCS01
Start Time: 2010-104T07:49:14.864 Stop Time: 2010-104T10:44:23.042
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101041414C_ACCS01
Start Time: 2010-104T14:14:29.824 Stop Time: 2010-104T17:43:55.387
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101042114C_ACCS01
Start Time: 2010-104T21:14:02.141 Stop Time: 2010-105T00:43:27.954
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101050413C_ACCS01
Start Time: 2010-105T04:13:34.610 Stop Time: 2010-105T07:43:32.481
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101051113C_ACCS01
Start Time: 2010-105T11:13:07.137 Stop Time: 2010-105T12:23:41.595
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101051227C_ACCS01
Start Time: 2010-105T12:27:21.315 Stop Time: 2010-105T14:42:49.889
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101051847C_ACCS01
Start Time: 2010-105T18:47:30.861 Stop Time: 2010-105T21:42:38.817
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101060112C_ACCS01
Start Time: 2010-106T01:12:45.566 Stop Time: 2010-106T04:42:11.347
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101060812C_ACCS01
Start Time: 2010-106T08:12:18.035 Stop Time: 2010-106T09:07:46.207
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101060911C_ACCS01
Start Time: 2010-106T09:11:25.989 Stop Time: 2010-106T11:41:55.035
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101070511C_ACCS01
Start Time: 2010-107T05:11:16.989 Stop Time: 2010-107T08:41:14.865
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101071210C_ACCS01
Start Time: 2010-107T12:10:49.522 Stop Time: 2010-107T15:40:47.493
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101071910C_ACCS01
Start Time: 2010-107T19:10:22.118 Stop Time: 2010-107T20:21:03.857
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101072024C_ACCS01
Start Time: 2010-107T20:24:43.734 Stop Time: 2010-107T22:40:11.870
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101080244C_ACCS01
Start Time: 2010-108T02:44:44.906 Stop Time: 2010-108T05:39:52.082
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101080909C_ACCS01
Start Time: 2010-108T09:09:58.802 Stop Time: 2010-108T12:39:56.583
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101081609C_ACCS01
Start Time: 2010-108T16:09:31.238 Stop Time: 2010-108T19:39:29.110
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101082309C_ACCS01
Start Time: 2010-108T23:09:03.769 Stop Time: 2010-109T00:19:34.759
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101090023C_ACCS01
Start Time: 2010-109T00:23:14.759 Stop Time: 2010-109T02:38:43.521
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101090643C_ACCS01
Start Time: 2010-109T06:43:15.986 Stop Time: 2010-109T09:38:23.317
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101091308C_ACCS01
Start Time: 2010-109T13:08:30.132 Stop Time: 2010-109T16:38:27.849
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101092008C_ACCS01
Start Time: 2010-109T20:08:02.534 Stop Time: 2010-109T21:18:34.336
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101092122C_ACCS01
Start Time: 2010-109T21:22:14.243 Stop Time: 2010-109T23:37:43.251
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101100342C_ACCS01
Start Time: 2010-110T03:42:12.793 Stop Time: 2010-110T06:37:20.970
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101101007C_ACCS01
Start Time: 2010-110T10:07:27.657 Stop Time: 2010-110T13:36:53.249
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101101707C_ACCS01
Start Time: 2010-110T17:07:00.001 Stop Time: 2010-110T20:36:25.152
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101110006C_ACCS01
Start Time: 2010-111T00:06:31.841 Stop Time: 2010-111T00:37:01.195
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101110040C_ACCS01
Start Time: 2010-111T00:40:40.820 Stop Time: 2010-111T03:36:21.063
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101110740C_ACCS01
Start Time: 2010-111T07:40:45.011 Stop Time: 2010-111T10:35:52.785
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101111405C_ACCS01
Start Time: 2010-111T14:05:59.506 Stop Time: 2010-111T17:35:57.286
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101112105C_ACCS01
Start Time: 2010-111T21:05:32.034 Stop Time: 2010-111T22:16:01.211
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101112219C_ACCS01
Start Time: 2010-111T22:19:40.774 Stop Time: 2010-112T00:35:09.282
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101120439C_ACCS01
Start Time: 2010-112T04:39:40.003 Stop Time: 2010-112T07:34:48.303
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101121104C_ACCS01
Start Time: 2010-112T11:04:55.022 Stop Time: 2010-112T14:34:20.490
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101121804C_ACCS01
Start Time: 2010-112T18:04:27.242 Stop Time: 2010-112T21:33:52.867
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101130103C_ACCS01
Start Time: 2010-113T01:03:59.556 Stop Time: 2010-113T04:33:57.335
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101130803C_ACCS01
Start Time: 2010-113T08:03:31.989 Stop Time: 2010-113T08:33:59.496
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101130837C_ACCS01
Start Time: 2010-113T08:37:39.121 Stop Time: 2010-113T11:33:19.550
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101131537C_ACCS01
Start Time: 2010-113T15:37:49.014 Stop Time: 2010-113T18:32:56.940
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101132203C_ACCS01
Start Time: 2010-113T22:03:03.691 Stop Time: 2010-114T01:32:29.690
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101140502C_ACCS01
Start Time: 2010-114T05:02:36.376 Stop Time: 2010-114T08:32:02.721
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101141202C_ACCS01
Start Time: 2010-114T12:02:09.411 Stop Time: 2010-114T13:12:29.213
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101141316C_ACCS01
Start Time: 2010-114T13:16:08.368 Stop Time: 2010-114T15:31:36.906
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101141936C_ACCS01
Start Time: 2010-114T19:36:04.881 Stop Time: 2010-114T22:31:12.186
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101150201C_ACCS01
Start Time: 2010-115T02:01:18.900 Stop Time: 2010-115T05:31:16.276
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101150900C_ACCS01
Start Time: 2010-115T09:00:50.932 Stop Time: 2010-115T12:30:48.837
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101151600C_ACCS01
Start Time: 2010-115T16:00:23.525 Stop Time: 2010-115T19:30:20.808
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101152259C_ACCS01
Start Time: 2010-115T22:59:55.490 Stop Time: 2010-115T23:30:35.468
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101152334C_ACCS01
Start Time: 2010-115T23:34:15.468 Stop Time: 2010-116T02:29:55.803
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101160634C_ACCS01
Start Time: 2010-116T06:34:12.893 Stop Time: 2010-116T09:29:21.039
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101161259C_ACCS01
Start Time: 2010-116T12:59:27.786 Stop Time: 2010-116T16:28:53.008
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101161958C_ACCS01
Start Time: 2010-116T19:58:59.756 Stop Time: 2010-116T21:09:14.088
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101162112C_ACCS01
Start Time: 2010-116T21:12:54.152 Stop Time: 2010-116T23:28:22.971
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101170333C_ACCS01
Start Time: 2010-117T03:33:02.886 Stop Time: 2010-117T06:28:11.125
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101170958C_ACCS01
Start Time: 2010-117T09:58:17.812 Stop Time: 2010-117T13:27:42.970
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101171657C_ACCS01
Start Time: 2010-117T16:57:49.660 Stop Time: 2010-117T20:27:47.776
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101172357C_ACCS01
Start Time: 2010-117T23:57:22.437 Stop Time: 2010-118T00:27:52.977
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101180031C_ACCS01
Start Time: 2010-118T00:31:32.915 Stop Time: 2010-118T03:27:13.061
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101180731C_ACCS01
Start Time: 2010-118T07:31:31.922 Stop Time: 2010-118T10:26:40.004
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101181356C_ACCS01
Start Time: 2010-118T13:56:46.694 Stop Time: 2010-118T17:26:12.569
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101182056C_ACCS01
Start Time: 2010-118T20:56:19.226 Stop Time: 2010-119T00:25:44.350
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101190355C_ACCS01
Start Time: 2010-119T03:55:51.068 Stop Time: 2010-119T05:06:16.901
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101190509C_ACCS01
Start Time: 2010-119T05:09:56.277 Stop Time: 2010-119T07:25:24.942
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101191130C_ACCS01
Start Time: 2010-119T11:30:00.883 Stop Time: 2010-119T14:25:08.310
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101191755C_ACCS01
Start Time: 2010-119T17:55:15.063 Stop Time: 2010-119T21:25:12.030
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101200054C_ACCS01
Start Time: 2010-120T00:54:46.720 Stop Time: 2010-120T02:05:16.113
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101200208C_ACCS01
Start Time: 2010-120T02:08:56.144 Stop Time: 2010-120T04:24:25.249
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101200828C_ACCS01
Start Time: 2010-120T08:28:55.981 Stop Time: 2010-120T11:24:04.223
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101201454C_ACCS01
Start Time: 2010-120T14:54:10.936 Stop Time: 2010-120T18:23:36.687
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101202153C_ACCS01
Start Time: 2010-120T21:53:43.377 Stop Time: 2010-120T23:04:00.929
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ELSSCIL20101202307C_ACCS01
Start Time: 2010-120T23:07:40.741 Stop Time: 2010-121T01:23:09.719
This file contains data from ELSSCIL:  Electron Spectrometer (ELS)
science data (SCI) from the low range (L) of the ELS power supply
with up to 128 steps returned in telemetry.  These step values are
in the SCAN rows of the data files in the form of deflection
potential (volts).  To convert each step per sector to center
electron energies (eV), use the K_FACTORS in the calibration
tables (K-factor * defl. volt = eV). Each SCAN row directly
corresponds to the previous 16 SENSOR rows where the SENSOR value
(c/acc) in a given column is the data sampled at the SCAN value
(deflection voltage) in that same column.  The SENSOR rows have
one more column than the SCAN rows.  The additional column is the
data quality indicator (last column) for that sensor data.  The
data values are formatted for a high level of accuracy and DO NOT
reflect the accuracy of the intrumentation.  The ELS Instrument is
mounted on a scanning platform that was activated for the first
time in January 2006.  The scanner may have moved from its
parked position or be in motion for some of this data.  Please
refer to the Data Set Catalog, ASPERA3_EDR_ELS_DS.CAT, for
detailed information about the data organization, science meaning,
data quality determination, data modes, etc.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench