• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Cassini >> MIMI
CASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE View Errata Order Volume Toggle viewing into expanded mode
CO-S-MIMI-4-LEMMS-CALIB-V1.0 PDS 3      CERTIFIED
Start Time: 2004-01-01 08:00:00 - Stop Time: 2017-09-16 10:00:00
CASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE
CASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE
Citiation Information
Author Vandegriff J., Kusterer M.B.
TitleCASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE
PublisherNASA Planetary Data System
Publication Year 2018
doi https://doi.org/10.17189/1519608
Top/ DATA/ LPHAAVG0_1MIN/ 2017 / click here to download folders and files
LPHAAVG0_1MIN_2017001_02
Start Time: 2017-001T00:00 Stop Time: 2017-002T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017002_02
Start Time: 2017-002T00:00 Stop Time: 2017-003T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017003_02
Start Time: 2017-003T00:00 Stop Time: 2017-004T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017004_02
Start Time: 2017-004T00:00 Stop Time: 2017-005T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017005_02
Start Time: 2017-005T00:00 Stop Time: 2017-006T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017006_02
Start Time: 2017-006T00:00 Stop Time: 2017-007T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017007_02
Start Time: 2017-007T00:00 Stop Time: 2017-008T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017008_02
Start Time: 2017-008T00:00 Stop Time: 2017-009T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017009_02
Start Time: 2017-009T00:00 Stop Time: 2017-010T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017010_02
Start Time: 2017-010T00:00 Stop Time: 2017-011T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017011_02
Start Time: 2017-011T00:00 Stop Time: 2017-012T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017012_02
Start Time: 2017-012T00:00 Stop Time: 2017-013T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017013_02
Start Time: 2017-013T00:00 Stop Time: 2017-014T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017014_02
Start Time: 2017-014T00:00 Stop Time: 2017-015T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017015_02
Start Time: 2017-015T00:00 Stop Time: 2017-016T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017016_02
Start Time: 2017-016T00:00 Stop Time: 2017-017T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017017_02
Start Time: 2017-017T00:00 Stop Time: 2017-018T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017018_02
Start Time: 2017-018T00:00 Stop Time: 2017-019T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017019_02
Start Time: 2017-019T00:00 Stop Time: 2017-020T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017020_02
Start Time: 2017-020T00:00 Stop Time: 2017-021T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017021_02
Start Time: 2017-021T00:00 Stop Time: 2017-022T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017022_02
Start Time: 2017-022T00:00 Stop Time: 2017-023T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017023_02
Start Time: 2017-023T00:00 Stop Time: 2017-024T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017024_02
Start Time: 2017-024T00:00 Stop Time: 2017-025T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017025_02
Start Time: 2017-025T00:00 Stop Time: 2017-026T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017026_02
Start Time: 2017-026T00:00 Stop Time: 2017-027T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017027_02
Start Time: 2017-027T00:00 Stop Time: 2017-028T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017028_02
Start Time: 2017-028T00:00 Stop Time: 2017-029T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017029_02
Start Time: 2017-029T00:00 Stop Time: 2017-030T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017030_02
Start Time: 2017-030T00:00 Stop Time: 2017-031T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017031_02
Start Time: 2017-031T00:00 Stop Time: 2017-032T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017032_02
Start Time: 2017-032T00:00 Stop Time: 2017-033T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017033_02
Start Time: 2017-033T00:00 Stop Time: 2017-034T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017034_02
Start Time: 2017-034T00:00 Stop Time: 2017-035T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017035_02
Start Time: 2017-035T00:00 Stop Time: 2017-036T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017036_02
Start Time: 2017-036T00:00 Stop Time: 2017-037T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017037_02
Start Time: 2017-037T00:00 Stop Time: 2017-038T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017038_02
Start Time: 2017-038T00:00 Stop Time: 2017-039T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017039_02
Start Time: 2017-039T00:00 Stop Time: 2017-040T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017040_02
Start Time: 2017-040T00:00 Stop Time: 2017-041T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017041_02
Start Time: 2017-041T00:00 Stop Time: 2017-042T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017042_02
Start Time: 2017-042T00:00 Stop Time: 2017-043T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017043_02
Start Time: 2017-043T00:00 Stop Time: 2017-044T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017044_02
Start Time: 2017-044T00:00 Stop Time: 2017-045T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017045_02
Start Time: 2017-045T00:00 Stop Time: 2017-046T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017046_02
Start Time: 2017-046T00:00 Stop Time: 2017-047T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017047_02
Start Time: 2017-047T00:00 Stop Time: 2017-048T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017048_02
Start Time: 2017-048T00:00 Stop Time: 2017-049T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017049_02
Start Time: 2017-049T00:00 Stop Time: 2017-050T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017050_02
Start Time: 2017-050T00:00 Stop Time: 2017-051T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017051_02
Start Time: 2017-051T00:00 Stop Time: 2017-052T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017052_02
Start Time: 2017-052T00:00 Stop Time: 2017-053T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017053_02
Start Time: 2017-053T00:00 Stop Time: 2017-054T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017054_02
Start Time: 2017-054T00:00 Stop Time: 2017-055T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017055_02
Start Time: 2017-055T00:00 Stop Time: 2017-056T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017056_02
Start Time: 2017-056T00:00 Stop Time: 2017-057T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017057_02
Start Time: 2017-057T00:00 Stop Time: 2017-058T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017058_02
Start Time: 2017-058T00:00 Stop Time: 2017-059T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017059_02
Start Time: 2017-059T00:00 Stop Time: 2017-060T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017060_02
Start Time: 2017-060T00:00 Stop Time: 2017-061T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017061_02
Start Time: 2017-061T00:00 Stop Time: 2017-062T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017062_02
Start Time: 2017-062T00:00 Stop Time: 2017-063T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017063_02
Start Time: 2017-063T00:00 Stop Time: 2017-064T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017064_02
Start Time: 2017-064T00:00 Stop Time: 2017-065T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017065_02
Start Time: 2017-065T00:00 Stop Time: 2017-066T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017066_02
Start Time: 2017-066T00:00 Stop Time: 2017-067T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017067_02
Start Time: 2017-067T00:00 Stop Time: 2017-068T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017068_02
Start Time: 2017-068T00:00 Stop Time: 2017-069T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017069_02
Start Time: 2017-069T00:00 Stop Time: 2017-070T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017070_02
Start Time: 2017-070T00:00 Stop Time: 2017-071T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017071_02
Start Time: 2017-071T00:00 Stop Time: 2017-072T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017072_02
Start Time: 2017-072T00:00 Stop Time: 2017-073T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017073_02
Start Time: 2017-073T00:00 Stop Time: 2017-074T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017074_02
Start Time: 2017-074T00:00 Stop Time: 2017-075T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017075_02
Start Time: 2017-075T00:00 Stop Time: 2017-076T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017076_02
Start Time: 2017-076T00:00 Stop Time: 2017-077T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017077_02
Start Time: 2017-077T00:00 Stop Time: 2017-078T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017078_02
Start Time: 2017-078T00:00 Stop Time: 2017-079T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017079_02
Start Time: 2017-079T00:00 Stop Time: 2017-080T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017080_02
Start Time: 2017-080T00:00 Stop Time: 2017-081T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017081_02
Start Time: 2017-081T00:00 Stop Time: 2017-082T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017082_02
Start Time: 2017-082T00:00 Stop Time: 2017-083T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017083_02
Start Time: 2017-083T00:00 Stop Time: 2017-084T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017084_02
Start Time: 2017-084T00:00 Stop Time: 2017-085T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017085_02
Start Time: 2017-085T00:00 Stop Time: 2017-086T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017086_02
Start Time: 2017-086T00:00 Stop Time: 2017-087T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017087_02
Start Time: 2017-087T00:00 Stop Time: 2017-088T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017088_02
Start Time: 2017-088T00:00 Stop Time: 2017-089T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017089_02
Start Time: 2017-089T00:00 Stop Time: 2017-090T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017090_02
Start Time: 2017-090T00:00 Stop Time: 2017-091T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017091_02
Start Time: 2017-091T00:00 Stop Time: 2017-092T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017092_02
Start Time: 2017-092T00:00 Stop Time: 2017-093T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017093_02
Start Time: 2017-093T00:00 Stop Time: 2017-094T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017094_02
Start Time: 2017-094T00:00 Stop Time: 2017-095T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017095_02
Start Time: 2017-095T00:00 Stop Time: 2017-096T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017096_02
Start Time: 2017-096T00:00 Stop Time: 2017-097T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017097_02
Start Time: 2017-097T00:00 Stop Time: 2017-098T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017098_02
Start Time: 2017-098T00:00 Stop Time: 2017-099T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017099_02
Start Time: 2017-099T00:00 Stop Time: 2017-100T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017100_02
Start Time: 2017-100T00:00 Stop Time: 2017-101T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017101_02
Start Time: 2017-101T00:00 Stop Time: 2017-102T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017102_02
Start Time: 2017-102T00:00 Stop Time: 2017-103T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017103_02
Start Time: 2017-103T00:00 Stop Time: 2017-104T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017104_02
Start Time: 2017-104T00:00 Stop Time: 2017-105T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017105_02
Start Time: 2017-105T00:00 Stop Time: 2017-106T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017106_02
Start Time: 2017-106T00:00 Stop Time: 2017-107T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017107_02
Start Time: 2017-107T00:00 Stop Time: 2017-108T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017108_02
Start Time: 2017-108T00:00 Stop Time: 2017-109T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017109_02
Start Time: 2017-109T00:00 Stop Time: 2017-110T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017110_02
Start Time: 2017-110T00:00 Stop Time: 2017-111T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017111_02
Start Time: 2017-111T00:00 Stop Time: 2017-112T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017112_02
Start Time: 2017-112T00:00 Stop Time: 2017-113T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017113_02
Start Time: 2017-113T00:00 Stop Time: 2017-114T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017114_02
Start Time: 2017-114T00:00 Stop Time: 2017-115T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017115_02
Start Time: 2017-115T00:00 Stop Time: 2017-116T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017116_02
Start Time: 2017-116T00:00 Stop Time: 2017-117T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017117_02
Start Time: 2017-117T00:00 Stop Time: 2017-118T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017118_02
Start Time: 2017-118T00:00 Stop Time: 2017-119T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017119_02
Start Time: 2017-119T00:00 Stop Time: 2017-120T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017120_02
Start Time: 2017-120T00:00 Stop Time: 2017-121T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017121_02
Start Time: 2017-121T00:00 Stop Time: 2017-122T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017122_02
Start Time: 2017-122T00:00 Stop Time: 2017-123T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017123_02
Start Time: 2017-123T00:00 Stop Time: 2017-124T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017124_02
Start Time: 2017-124T00:00 Stop Time: 2017-125T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017125_02
Start Time: 2017-125T00:00 Stop Time: 2017-126T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017126_02
Start Time: 2017-126T00:00 Stop Time: 2017-127T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017127_02
Start Time: 2017-127T00:00 Stop Time: 2017-128T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017128_02
Start Time: 2017-128T00:00 Stop Time: 2017-129T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017129_02
Start Time: 2017-129T00:00 Stop Time: 2017-130T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017130_02
Start Time: 2017-130T00:00 Stop Time: 2017-131T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017131_02
Start Time: 2017-131T00:00 Stop Time: 2017-132T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017132_02
Start Time: 2017-132T00:00 Stop Time: 2017-133T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017133_02
Start Time: 2017-133T00:00 Stop Time: 2017-134T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017134_02
Start Time: 2017-134T00:00 Stop Time: 2017-135T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017135_02
Start Time: 2017-135T00:00 Stop Time: 2017-136T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017136_02
Start Time: 2017-136T00:00 Stop Time: 2017-137T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017137_02
Start Time: 2017-137T00:00 Stop Time: 2017-138T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017138_02
Start Time: 2017-138T00:00 Stop Time: 2017-139T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017139_02
Start Time: 2017-139T00:00 Stop Time: 2017-140T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017140_02
Start Time: 2017-140T00:00 Stop Time: 2017-141T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017141_02
Start Time: 2017-141T00:00 Stop Time: 2017-142T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017142_02
Start Time: 2017-142T00:00 Stop Time: 2017-143T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017143_02
Start Time: 2017-143T00:00 Stop Time: 2017-144T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017144_02
Start Time: 2017-144T00:00 Stop Time: 2017-145T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017145_02
Start Time: 2017-145T00:00 Stop Time: 2017-146T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017146_02
Start Time: 2017-146T00:00 Stop Time: 2017-147T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017147_02
Start Time: 2017-147T00:00 Stop Time: 2017-148T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017148_02
Start Time: 2017-148T00:00 Stop Time: 2017-149T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017149_02
Start Time: 2017-149T00:00 Stop Time: 2017-150T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017150_02
Start Time: 2017-150T00:00 Stop Time: 2017-151T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017151_02
Start Time: 2017-151T00:00 Stop Time: 2017-152T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017152_02
Start Time: 2017-152T00:00 Stop Time: 2017-153T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017153_02
Start Time: 2017-153T00:00 Stop Time: 2017-154T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017154_02
Start Time: 2017-154T00:00 Stop Time: 2017-155T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017155_02
Start Time: 2017-155T00:00 Stop Time: 2017-156T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017156_02
Start Time: 2017-156T00:00 Stop Time: 2017-157T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017157_02
Start Time: 2017-157T00:00 Stop Time: 2017-158T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017158_02
Start Time: 2017-158T00:00 Stop Time: 2017-159T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017159_02
Start Time: 2017-159T00:00 Stop Time: 2017-160T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017160_02
Start Time: 2017-160T00:00 Stop Time: 2017-161T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017161_02
Start Time: 2017-161T00:00 Stop Time: 2017-162T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017162_02
Start Time: 2017-162T00:00 Stop Time: 2017-163T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017163_02
Start Time: 2017-163T00:00 Stop Time: 2017-164T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017164_02
Start Time: 2017-164T00:00 Stop Time: 2017-165T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017165_02
Start Time: 2017-165T00:00 Stop Time: 2017-166T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017166_02
Start Time: 2017-166T00:00 Stop Time: 2017-167T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017167_02
Start Time: 2017-167T00:00 Stop Time: 2017-168T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017168_02
Start Time: 2017-168T00:00 Stop Time: 2017-169T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017169_02
Start Time: 2017-169T00:00 Stop Time: 2017-170T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017170_02
Start Time: 2017-170T00:00 Stop Time: 2017-171T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017171_02
Start Time: 2017-171T00:00 Stop Time: 2017-172T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017172_02
Start Time: 2017-172T00:00 Stop Time: 2017-173T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017173_02
Start Time: 2017-173T00:00 Stop Time: 2017-174T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017174_02
Start Time: 2017-174T00:00 Stop Time: 2017-175T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017175_02
Start Time: 2017-175T00:00 Stop Time: 2017-176T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017176_02
Start Time: 2017-176T00:00 Stop Time: 2017-177T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017177_02
Start Time: 2017-177T00:00 Stop Time: 2017-178T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017178_02
Start Time: 2017-178T00:00 Stop Time: 2017-179T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017179_02
Start Time: 2017-179T00:00 Stop Time: 2017-180T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017180_02
Start Time: 2017-180T00:00 Stop Time: 2017-181T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017181_02
Start Time: 2017-181T00:00 Stop Time: 2017-182T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017182_02
Start Time: 2017-182T00:00 Stop Time: 2017-183T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017183_02
Start Time: 2017-183T00:00 Stop Time: 2017-184T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017184_02
Start Time: 2017-184T00:00 Stop Time: 2017-185T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017185_02
Start Time: 2017-185T00:00 Stop Time: 2017-186T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017186_02
Start Time: 2017-186T00:00 Stop Time: 2017-187T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017187_02
Start Time: 2017-187T00:00 Stop Time: 2017-188T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017188_02
Start Time: 2017-188T00:00 Stop Time: 2017-189T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017189_02
Start Time: 2017-189T00:00 Stop Time: 2017-190T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017190_02
Start Time: 2017-190T00:00 Stop Time: 2017-191T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017191_02
Start Time: 2017-191T00:00 Stop Time: 2017-192T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017192_02
Start Time: 2017-192T00:00 Stop Time: 2017-193T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017193_02
Start Time: 2017-193T00:00 Stop Time: 2017-194T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017194_02
Start Time: 2017-194T00:00 Stop Time: 2017-195T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017195_02
Start Time: 2017-195T00:00 Stop Time: 2017-196T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017196_02
Start Time: 2017-196T00:00 Stop Time: 2017-197T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017197_02
Start Time: 2017-197T00:00 Stop Time: 2017-198T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017198_02
Start Time: 2017-198T00:00 Stop Time: 2017-199T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017199_02
Start Time: 2017-199T00:00 Stop Time: 2017-200T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017200_02
Start Time: 2017-200T00:00 Stop Time: 2017-201T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017201_02
Start Time: 2017-201T00:00 Stop Time: 2017-202T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017202_02
Start Time: 2017-202T00:00 Stop Time: 2017-203T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017203_02
Start Time: 2017-203T00:00 Stop Time: 2017-204T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017204_02
Start Time: 2017-204T00:00 Stop Time: 2017-205T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017205_02
Start Time: 2017-205T00:00 Stop Time: 2017-206T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017206_02
Start Time: 2017-206T00:00 Stop Time: 2017-207T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017207_02
Start Time: 2017-207T00:00 Stop Time: 2017-208T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017208_02
Start Time: 2017-208T00:00 Stop Time: 2017-209T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017209_02
Start Time: 2017-209T00:00 Stop Time: 2017-210T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017210_02
Start Time: 2017-210T00:00 Stop Time: 2017-211T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017211_02
Start Time: 2017-211T00:00 Stop Time: 2017-212T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017212_02
Start Time: 2017-212T00:00 Stop Time: 2017-213T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017213_02
Start Time: 2017-213T00:00 Stop Time: 2017-214T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017214_02
Start Time: 2017-214T00:00 Stop Time: 2017-215T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017215_02
Start Time: 2017-215T00:00 Stop Time: 2017-216T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017216_02
Start Time: 2017-216T00:00 Stop Time: 2017-217T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017217_02
Start Time: 2017-217T00:00 Stop Time: 2017-218T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017218_02
Start Time: 2017-218T00:00 Stop Time: 2017-219T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017219_02
Start Time: 2017-219T00:00 Stop Time: 2017-220T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017220_02
Start Time: 2017-220T00:00 Stop Time: 2017-221T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017221_02
Start Time: 2017-221T00:00 Stop Time: 2017-222T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017222_02
Start Time: 2017-222T00:00 Stop Time: 2017-223T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017223_02
Start Time: 2017-223T00:00 Stop Time: 2017-224T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017224_02
Start Time: 2017-224T00:00 Stop Time: 2017-225T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017225_02
Start Time: 2017-225T00:00 Stop Time: 2017-226T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017226_02
Start Time: 2017-226T00:00 Stop Time: 2017-227T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017227_02
Start Time: 2017-227T00:00 Stop Time: 2017-228T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017228_02
Start Time: 2017-228T00:00 Stop Time: 2017-229T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017229_02
Start Time: 2017-229T00:00 Stop Time: 2017-230T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017230_02
Start Time: 2017-230T00:00 Stop Time: 2017-231T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017231_02
Start Time: 2017-231T00:00 Stop Time: 2017-232T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017232_02
Start Time: 2017-232T00:00 Stop Time: 2017-233T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017233_02
Start Time: 2017-233T00:00 Stop Time: 2017-234T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017234_02
Start Time: 2017-234T00:00 Stop Time: 2017-235T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017235_02
Start Time: 2017-235T00:00 Stop Time: 2017-236T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017236_02
Start Time: 2017-236T00:00 Stop Time: 2017-237T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017237_02
Start Time: 2017-237T00:00 Stop Time: 2017-238T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017238_02
Start Time: 2017-238T00:00 Stop Time: 2017-239T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017239_02
Start Time: 2017-239T00:00 Stop Time: 2017-240T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017240_02
Start Time: 2017-240T00:00 Stop Time: 2017-241T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017241_02
Start Time: 2017-241T00:00 Stop Time: 2017-242T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017242_02
Start Time: 2017-242T00:00 Stop Time: 2017-243T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017243_02
Start Time: 2017-243T00:00 Stop Time: 2017-244T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017244_02
Start Time: 2017-244T00:00 Stop Time: 2017-245T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017245_02
Start Time: 2017-245T00:00 Stop Time: 2017-246T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017246_02
Start Time: 2017-246T00:00 Stop Time: 2017-247T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017247_02
Start Time: 2017-247T00:00 Stop Time: 2017-248T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017248_02
Start Time: 2017-248T00:00 Stop Time: 2017-249T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017249_02
Start Time: 2017-249T00:00 Stop Time: 2017-250T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017250_02
Start Time: 2017-250T00:00 Stop Time: 2017-251T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017251_02
Start Time: 2017-251T00:00 Stop Time: 2017-252T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017252_02
Start Time: 2017-252T00:00 Stop Time: 2017-253T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017253_02
Start Time: 2017-253T00:00 Stop Time: 2017-254T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017254_02
Start Time: 2017-254T00:00 Stop Time: 2017-255T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017255_02
Start Time: 2017-255T00:00 Stop Time: 2017-256T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017256_02
Start Time: 2017-256T00:00 Stop Time: 2017-257T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017257_02
Start Time: 2017-257T00:00 Stop Time: 2017-258T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2017258_02
Start Time: 2017-258T00:00 Stop Time: 2017-259T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench